Literature DB >> 1928108

A longitudinal study of pulmonary function in fire fighters.

A Tepper1, G W Comstock, M Levine.   

Abstract

Pulmonary function changes among fire fighters were evaluated by re-examining 632 Baltimore city fire fighters six to ten years after a baseline examination. Spirometry was used to determine forced expiratory volume in 1 second (FEV1). Information about exposures was obtained by questionnaire and by combining data from fire department records regarding the number of fires fought by fire fighting units with individual work histories. Men who never wore a mask while extinguishing fires experienced a 1.7 times greater rate of FEV1 decline than mask wearers. Men with ammonia exposure experienced a rate of decline 1.7 times greater than non-exposed men. Neither length of time spent in exposed jobs nor number of responses were associated with the rate of decline. Active fire fighters experienced a rate of decline 2.5 times greater than those who had retired or resigned. Some effects differed between men who were able to perform repeatable pulmonary function tests and those who were not.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1928108     DOI: 10.1002/ajim.4700200304

Source DB:  PubMed          Journal:  Am J Ind Med        ISSN: 0271-3586            Impact factor:   2.214


  7 in total

1.  Lung function and health status in metropolitan fire-fighters compared to general population controls.

Authors:  Tjard Schermer; Trish Malbon; Michael Morgan; Nancy Briggs; Christine Holton; Sarah Appleton; Robbert Adams; Michael Smith; Alan Crockett
Journal:  Int Arch Occup Environ Health       Date:  2010-04-03       Impact factor: 3.015

2.  Respiratory protection programs for firefighters: a survey of practices for the state of Kentucky.

Authors:  Gregory H Easterling; Scott Prince
Journal:  Public Health Rep       Date:  2007 Nov-Dec       Impact factor: 2.792

3.  Lung function measures following simulated wildland firefighter exposures.

Authors:  Matthew D Ferguson; Erin O Semmens; Emily Weiler; Joe Domitrovich; Mary French; Christopher Migliaccio; Charles Palmer; Charles Dumke; Tony Ward
Journal:  J Occup Environ Hyg       Date:  2017-09       Impact factor: 2.155

4.  Chronic respiratory conditions in a cohort of metropolitan fire-fighters: associations with occupational exposure and quality of life.

Authors:  Tjard R Schermer; Winifred Malbon; Michael Morgan; Michael Smith; Alan J Crockett
Journal:  Int Arch Occup Environ Health       Date:  2014-02-26       Impact factor: 3.015

5.  The long-term rate of change in lung function in urban professional firefighters: a systematic review.

Authors:  Flynn Slattery; Kylie Johnston; Catherine Paquet; Hunter Bennett; Alan Crockett
Journal:  BMC Pulm Med       Date:  2018-09-06       Impact factor: 3.317

6.  Decreased Pulmonary Function Over 5 Years in US Firefighters.

Authors:  Kevin C Mathias; Elliot Graham; Donald Stewart; Denise L Smith
Journal:  J Occup Environ Med       Date:  2020-10       Impact factor: 2.306

7.  Firefighters and COVID-19: An Occupational Health Perspective.

Authors:  Elliot L Graham; Saeed Khaja; Alberto J Caban-Martinez; Denise L Smith
Journal:  J Occup Environ Med       Date:  2021-08-01       Impact factor: 2.306

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.