Literature DB >> 19275443

Bioreactor for biaxial mechanical stimulation to tissue engineered constructs.

Karin A Wartella1, Jennifer S Wayne.   

Abstract

The complex structure and properties of biological tissues as well as their in situ environment often make it difficult to self-heal. A suitable replacement tissue may be created in vitro through tissue engineering approaches and mechanical stimulation of tissue constructs. A new biaxial bioreactor was designed, constructed, and evaluated for the purposes of developing constructs with specific functional characteristics. Once constructed and assembled, the bioreactor was tested for position accuracy and application of strain. Additionally, a tissue construct was tested in the chamber and compared with a nonstimulated construct. Results showed high position accuracy, but some loss between applied strain via grip movement and strain experienced by the scaffold. The tested construct exhibited an increase in cells and matrix deposition in comparison to the nonstimulated construct. This biaxial bioreactor will be useful for mechanically stimulating tissue constructs in two perpendicular directions to create implants for tissues requiring preferred compressive and tensile resistances.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19275443     DOI: 10.1115/1.3049859

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  6 in total

1.  Design and performance of an optically accessible, low-volume, mechanobioreactor for long-term study of living constructs.

Authors:  Jeffrey A Paten; Ramin Zareian; Nima Saeidi; Suzanna A Melotti; Jeffrey W Ruberti
Journal:  Tissue Eng Part C Methods       Date:  2011-04-21       Impact factor: 3.056

2.  Design of a biaxial mechanical loading bioreactor for tissue engineering.

Authors:  Bahar Bilgen; Danielle Chu; Robert Stefani; Roy K Aaron
Journal:  J Vis Exp       Date:  2013-04-25       Impact factor: 1.355

Review 3.  A Guide for Using Mechanical Stimulation to Enhance Tissue-Engineered Articular Cartilage Properties.

Authors:  Evelia Y Salinas; Jerry C Hu; Kyriacos Athanasiou
Journal:  Tissue Eng Part B Rev       Date:  2018-04-26       Impact factor: 6.389

4.  Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

Authors:  Kimberly J Schipke; S D Filip To; James N Warnock
Journal:  J Vis Exp       Date:  2011-08-23       Impact factor: 1.355

Review 5.  Three-dimensional osteogenic and chondrogenic systems to model osteochondral physiology and degenerative joint diseases.

Authors:  Peter G Alexander; Riccardo Gottardi; Hang Lin; Thomas P Lozito; Rocky S Tuan
Journal:  Exp Biol Med (Maywood)       Date:  2014-07-03

6.  Computational fluid dynamics for enhanced tracheal bioreactor design and long-segment graft recellularization.

Authors:  Hankyu Lee; Alba E Marin-Araujo; Fabio G Aoki; Siba Haykal; Thomas K Waddell; Cristina H Amon; David A Romero; Golnaz Karoubi
Journal:  Sci Rep       Date:  2021-01-13       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.