Literature DB >> 19274409

[Evaluation of optical performance of soft contact lenses in myopic correction].

Marcelo Weslley Dalcoll1, Mílton Ruiz Alves, Jackson Barreto, Iris de Souza Yamane, Samir Bechara, Adriana Mukai.   

Abstract

PURPOSE: To evaluate the optical performance of eyes fitted with two different soft contact lenses: Acuvue 2 (Vistacon J&J Vision Care Inc., USA) and World Vision Disposable Asférica Wave Front (World Vision Ophthalmic, Brazil).
METHODS: An interventional prospective clinical trial studied a sample of 40 myopic patients (-0.75D to -4.50D, with or without astigmatism up to -0.75D). Each patient had one eye randomized to visual performance evaluation including high and low contrast visual acuities, wavefront analysis and contrast sensitivity.
RESULTS: The Nidek OPD Scan detected a residual refraction (hypercorrection) for both contact lenses. High contrast visual acuity was significantly higher for World Vision soft contact lenses. Low contrast visual acuity was similar for both soft contact lenses. Contrast sensitivity improved significantly at 1.5; 3; 6 e 18 spatial frequencies for both soft contact lenses, but no difference was found between them. Regarding wavefront analysis, no difference was found between both soft contact lenses. There were not significantly differences in the Strehl indices and MTF for both soft contact lenses.
CONCLUSION: World Vision Disposable Asférica Wave Front soft contact lenses had a better performance regarding high contrast visual acuity. However, low contrast visual acuity, wavefront analysis and contrast sensitivity were similar for both soft contact lenses.

Entities:  

Mesh:

Year:  2008        PMID: 19274409     DOI: 10.1590/s0004-27492008000700008

Source DB:  PubMed          Journal:  Arq Bras Oftalmol        ISSN: 0004-2749            Impact factor:   0.872


  3 in total

1.  Spherical aberration and higher order aberrations with Balafilcon A (PureVision) and Comfilcon A (Biofinity).

Authors:  Colm McAlinden; Jonathan E Moore; Victoria E McGilligan; Tara C B Moore
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-08-06       Impact factor: 3.117

2.  Epidemiology, genetics and treatments for myopia.

Authors:  Lei Yu; Zhi-Kui Li; Jin-Rong Gao; Jian-Rong Liu; Chang-Tai Xu
Journal:  Int J Ophthalmol       Date:  2011-12-18       Impact factor: 1.779

3.  Contrast sensitivity function with soft contact lens wear.

Authors:  Kishor Sapkota; Sandra Franco; Madalena Lira
Journal:  J Optom       Date:  2020-02-13
  3 in total