Correlation between metal-ceramic bond strength and coefficient of linear thermal expansion difference.

Stella Crosara Lopes1, Valéria Oliveira Pagnano, João Manuel Domingos de Almeida Rollo, Mônica Barbosa Leal, Osvaldo Luiz Bezzon.   

Abstract

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10(-6) oC(-1)) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19274398      PMCID: PMC4327589          DOI: 10.1590/s1678-77572009000200010

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Metal-ceramic compatibility is an important factor in manufacturing metal-ceramic restorations. The coefficient of linear thermal expansion (CTE), thermal conductivity and the nature and strength of the bond are all factors that influence the porcelain's capacity to resist fracture during clinical use of the restoration11,21. In agreement with many authors, the difference in CTEs of porcelain and metal has been recognized as a major parameter in predicting compatibility1,4,12,24. The general consensus is that the alloy should have higher CTE than the porcelain (a positive expansion coefficient mismatch) in order to produce compressive stress in the porcelain when cooling11,24. Usually, a variation ranging from 0.5 to 1.0 × 10-6 °C-1 between the CTEs of the alloy and ceramic is considered adequate when the metal coefficient is higher than that of the ceramic. It keeps the ceramic compressed; increasing the lifetime of the restoration3. Some authors reported that metal-ceramic specimens with a negative CTE difference failed at significantly lower flexural loads than specimens did with positive CTE difference2,10. Various tests have been designed and selected by researchers to evaluate metal-ceramic bond strength and the minimal value recommended by the ISO standard 969315 for metal-ceramic dental restorative systems is 25 MPa for 3-point bending test. However, it can be affirmed that this value is related more to the flexure strength of the metallic substrate than to the metal-ceramic bond strength12,13,18, causing difficulty when comparing different metallic substrates. Noble metal alloys had been widely used for porcelain veneering in dentistry. However, with the continuous price fluctuations of noble metals, more attention has been given to alternative alloys. Ni-Cr alloys have good mechanical properties, such as high degree of hardness, low density and high tensile strength. Also, the low cost and easy fabrication of Ni-Cr alloys have caused them to be widely used in dental fixed prosthesis for quite some time14. The addition of Be in these Ni-Cr alloys promoted castability improvement of these alloys and enhanced bonding strength between porcelain and metal3,6,14,17,20,23. However, in addition to beryllium, the presence of other potentially pathogenic metallic components in Ni-Cr alloys has contributed for reinsertion of Pd-Ag in the market5,8. Porcelains suitable for Pd-Ag alloys were then developed, which avoid wearing of the ceramic coverage by Ag diffusion in ceramics7,9 evidencing that this alloy system is safer than alloys with Ni 7. High palladium alloys were introduced in the early 1980s and are currently widely used in metal-ceramic restorations, even though they have not yet been scientifically investigated to the extent that their widespread use requires10,13,14,17,18. This type of alloy presents characteristics that, in spite of not interfering with the porcelain-to-metal bond, must be observed. Moreover, there are elements in the alloy composition, such as silver and tin, which are susceptible to oxidation. Thus, previous oxidation is an important procedure that could increase the bond strength of such metal-ceramic interface1,16,19. Furthermore, the Pd-Ag alloy (Pors-on 4) presents much smaller grains than other Pd-Ag alloys that provide better mechanical qualities, besides promoting larger external contact surface14. Another characteristic of the palladium alloy is its high sensitivity to the presence of carbon during casting procedures. This could generate problems such as ceramic porosities and carbon contamination in the alloy6,15,17,18. The carbon promotes a formation of carbon monoxide during the ceramic baking, creating bubbles and porosities, which could be partly responsible for undesirable outcomes, such as cracks or fractures. The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys with/without Be and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the CTEs of the metals and ceramics.

MATERIAL AND METHODS

Two Ni-Cr alloys - Verabond (VB) with Be and Verabond II (VB2) without Be -and one Pd-Ag alloy - Pors-on 4 (P4) - were fused to 2 ceramics - IPS (I) and Duceram (D) - (Table 1) to form six metal-ceramic pairs (VBI, VBD, VB2I, VB2D, PI, and PD). Eight specimens of each metal-ceramic pair were used to test shear bond strength. Five dilatometric specimens from each alloy and ceramic were used to measure the CTE. The bond strength data were analyzed for correlation with differences in CTE.
TABLE 1

Commercial alloys, their compositions and manufacturers

MaterialComposition (wt %)Manufacturer
VerabondNi 77.95 (maximum); Cr 12.6; Mo 5.0; Al 2.9; Be 1.95 (maximum); Co 0.45; Ti 0.35Aalba Dent, Cordelia, CA, USA
Verabond IINi 77.05; Cr 12.5; Mo 4.25; Nb 4.0; Al 2.25; Si 0.5; Ti 0.45Aalba Dent, Cordelia, CA, USA
Pors-on 4Pd 57.8; Ag 30.00; Rn 0.2; Sn 6.0; Zn 2.0; In 4.0Degussa S.A., Dusseldorf, Germany
IPSAl2O3; B2O3. BaO; CaO; CeO2; K2O; MgO; Na2O; P2O5; SiO2; TiO2; ZrO2 Ivoclar 2/Fi, Shaan, Liechtenstein
DuceramSiO2; B2O3; Al2O3; K2O; Na2O; Li2O; BaO; CaO; SnO2; MgO; Sb2O3; TiO2; P2O5; ZrO2; F; Fe2O3 Degussa S.A., Dusseldorf, Germany
The metal-ceramic bond strength test was established on previously published techniques1,6,22, which determine the shear strength needed to break the metal-ceramic bond of a ceramic ring constructed around cylinder-shaped metal rods. The cast metal specimens were not submitted to any preheating treatment before applying ceramic. The ceramic rings were assembled with IPS porcelain and Duceram and manipulated according to the manufacturer's recommendations without any pre-heating treatment, since the Verabond manufacturer does not suggest pre-heating for single crowns, only for three-element fixed partial dentures. The ceramic firing cycles are listed in Table 2.
TABLE 2

Ceramic firing cycles

CeramicLayerFiring temperature (°C)Firing time (min)Maintenance time (min)
IPSOpaque
1st layer550-9805* 1ö
2nd layer550-9705* 1ö
Dentin
1st layer580-9205* 1ö
2nd layer580-9105* 1ö
DuceramOpaque
1st layer600-9305* 1.5ö
2nd layer600-9255* 1.5ö
Dentin
1st layer575-9105* 1ö
2nd layer575-9005* 1ö

Under vacuum.

Without vacuum.

Under vacuum. Without vacuum. Each specimen was calibrated with a handheld digital caliper (Mitutoyo Digimatic Caliper, model 500-151, Mitutoyo Corp, Tokyo, Japan) as a function of the dimensional alterations inherent to the casting and ceramic firing processes. Eight individual specimens were cast for each alloy, being 1 for each casting ring. Metal rods were obtained to place brass rods, measuring 3.0 mm in diameter and 70.0 in length, inside a phosphate-bonded investment (Termocast; Polidental, Sao Paulo, Brazil). After investment hardening, using pliers, the brass rods were removed from the cast by the exposed end at the base of the casting ring. Casting rings were then burned out and cast. After the rings cooled, the castings were manually divested and airbone-particle abraded (Model Microjet II, EDG, São Carlos, SP, Brazil) with 100μm aluminum oxide abrasive (Polidental, Sao Paulo, SP, Brazil) under 2-bar pressure for 5 s, to remove residual investment. No preheating treatment was performed. For the fabrication of ceramic rings, silicone rubber cylinders measuring 7.0 mm in diameter and 6.0 mm high were fabricated, with a hole in the middle equal to the diameter of the rods in order to form a mold for the ceramic material. Each metal rod received a pair of these cylinders, each positioned by its free end to prevent any contamination from the construction site of the ceramic ring. One cylinder was positioned nearby the extremity of the metallic rod and the other one was inserted at the other end and moved until it encountered the spacer selected to standardize the thickness of the ceramic ring to 1.5 mm. Using a dental surveyor, the rings, assembled 6.0 mm from one end of the rods, were placed in the center of a plaster cylinder for load application. All steps of the metal-ceramic bond strength test are schematically illustrated in Figures 1 to 4. After plaster curing, the specimens were subjected to tensile loading in a universal testing machine (EMIC MEM 2000, São Jose dos Pinhais, PR, Brazil) by introducing opposite clamps, a self-locking one at the exposed end of the rod and another one projected to accommodate the plaster cylinders. The machine was set at a cross-head speed of 0.5 mm/min. The peak load was recorded and used to calculate the bond strength-indicating MCBS by the equation: T = F/s, where T = bond strength, F = critical rupture load, and s = area of the metal-ceramic bond. Thus, an area was obtained with the equation: s = p . d . t, where s = metal-ceramic bonding area, d = rod diameter, and t = ring thickness.
FIGURE 1

Ensemble mounted for opaque application and ceramic condensation: a) metal rod, b) spacer, c) cylinders of silicone

FIGURE 4

Ensemble mounted for application of tensile load: a) universal testing machine, b) traction clamps

The data were recorded and submitted to a one-way ANOVA and Tukey's test (α=0.01). Specimens measuring 12 mm in length and 2 mm in diameter were fabricated for the dilatometric test. Alloy specimens were obtained by machining the previously cast metallic stems from the studied alloys, in the mechanical vise. A capillary chromel-alumel thermocouple (0.8 mm in diameter) was welded to the specimen to check the temperature variation. Welding was accomplished by a micro-welder attached to the dilatometer. Ceramic specimens were obtained by 2-mm-diameter built-in irrigation cannulas (model 22G1; Sr Produtos Hospitalares, Manaus, AM, Brazil) in refractory material (Fortune, Williams Dent Co, Buffalo, NY, USA). The cannulas were removed after refractory setting, leaving the required space for further application of the ceramic. The investment was wet and the ceramic was applied in 2 steps. After the second firing of porcelain, finishing with low-speed diamond burs was done for final dimension adjustments. When the final dimensions were obtained, a groove was made in the center of the specimen for accommodation and building-in of the thermocouple, previously welded with porcelain gold flush. An additional porcelain layer was added, in order to retain the thermocouple inside it, which required a new firing for ceramic sintering. A dilatometer (Adamel Lhomargy, model DT 1000, NY, USA) was used for the dilatometric testing. Prior to the dilatometric tests, a complete heating/cooling cycle was performed in order to establish the temperature of each ceramic softening. The specimens were placed on the dilatometer and the cycle was performed, beginning at room temperature. The heating rate was 5°C/min, up to the moment that an inversion on the heating curve was noted on the monitoring screen. At this point, the test was interrupted and each porcelain softening temperature was determined. IPS softening temperature was 654.9°C and Duceram's was 644.8°C. Therefore a safe number for maximum temperature of the dilatometric test with ceramics was established at 620°C. Regarding the dilatometric test for ceramic specimens, a heating/cooling cycle was programmed at a heating rate of 5°C/min starting at room temperature and advancing to 620°C. At this temperature, the specimen was cooled down at a cooling rate of 5°C/min. and the determination of CTE was made from 500°C down to room temperature with air and helium gas injection. Metallic alloys were submitted to the entire cycle, which simulated the firing of ceramics. They were heated from room temperature up to 580°C under vacuum at a heating rate of 150°C/min and then up to 920°C at heating rate of 5°C/min. After reaching 920°C, vacuum was eliminated; the specimen was kept for one minute at this temperature and then cooled down to 500°C. From this temperature, the CTE was determined to a cooling rate of 5°C/min to room temperature. The CTE was the mean value of five specimens for each evaluated material. The data were recorded and submitted to one-way ANOVA and Tukey's test (α=0.05). Additionally, linear regression was performed to determine the correlation of MCBS and CTE differences.

RESULTS

Metal-Ceramic Bond Strength (MCBS) Test

Eight repetitions were performed for each of the 6 groups. The ANOVA and Tukey's test indicated statistically significant differences among the groups (p<0.01) (Tables 3 and 4). The PI par showed the highest MCBS (67.72 MPa). All other metal-ceramic pairs showed no significant differences.
TABLE 3

Results of ANOVA

FactorsSum of squares df Mean squareFP
Pairs5993.9251198.7811.90.001
Residue4229.5642100.70
Total variation10223.4847
TABLE 4

Metal-ceramic bond strength (MPa) results

Metal-ceramic pairMean (SD)
VBI38.61 (10.11) b
VBD43.12 (5.04) b
VB2I39.20 (10.44) b
VB2D41.65 (7.11) b
PI67.72 (16.19) a
PD32.73 (7.37) b

Groups with same superscript letter are not statistically different (p>.01)

Groups with same superscript letter are not statistically different (p>.01)

Dilatometric Test

Table 5 shows the single material CTE values and also means and standard deviations of the evaluated materials. Table 6 shows the differences among CTE values of ceramics and alloys, within the range of 100°C to 500°C, resulting from the mean of the five specimens for each evaluated material.
TABLE 5

Mean and standard deviation of CTE materials (10-5 °C-1)

MaterialMean (SD)
VB1.31 (0.06)
VB21.24 (0.05)
P1.44 (0.07)
I1.26 (0.08)
D1.18 (0.08)
TABLE 6

Differences among dilatometric coefficients of alloys and ceramics (10-6 °C-1)

Metal-ceramic pairCTE Difference
VBI0.54
VBD1.33
VB2I-0.14
VB2D0.63
PI1.84
PD2.62
For the correlation analysis of MCBS and CTE differences, the Pearson test was performed. There was not correlation between them (r=0.17). Figure 5 shows the scatter plot with a regression model superimposed.
FIGURE 5

Scatter plot of the correlation between MCBS (MPa) and CTE differences (1Q-6 °C-1)

DISCUSSION

The emergence of metal-ceramic restorations in the late 50's created the need to control CTE of metal alloys in order to guarantee the success of restorations by preventing the rupture of metal-ceramic bond3. Thermal compatibility of the metal-ceramic pair could play a significant role in MCBS because it constitutes the main physical requirement to avoid stress at the interface11,12,18,24. The CTEs of the metal and ceramics must be similar in order to avoid stress2,4,11,12,23. The recommended mean difference between alloy and ceramics CTEs (from room temperature to 600°C) is from 0.5 to 1.0 10-6 °C-1 3,23. The CTE differences between VB alloy and IPS ceramic (0.54 × 10-6 °C-1) and between VB2 and Duceram (0.63 × 10-6 °C-1) were found within the above mentioned range but did not guarantee high values of CMBS. The VBD pair difference was 1.33 × 10-6°C-1 while the VB2I pair showed a negative difference (-0.14 × 10-6°C-1). Although some authors3,10 recommend that the metal and porcelain should have similar coefficients of thermal contraction and metal must have a slightly higher value to avoid undesirable tensile loading at the interface, in this case the CTE of ceramic was higher than the alloy one, without significant differences observed in the MCBS values. Two situations can be found when comparing the CTE differences in this study. When there is a positive difference of CTEs, the CTE of alloy is higher than the CTE of ceramic, where ceramic is compressed and metal is under tension. This is found to be the most common combination in dental metal-ceramic systems. When the difference is negative, the CTE of ceramic is higher than the CTE of alloy, where ceramic is under tension and metal is compressed4. Differences much higher than the recommended average were found at the combination Pors-on 4 alloy and both studied ceramics (PI= 1.8 × 10-6°C-1; and PD= 2.6 × 10-6°C-1). Differences of 1.7 × 10-6°C-1 between the coefficients of the metal-ceramic pair produce tension in the porcelain close to the metal-ceramic interface during the cooling of porcelain, possibly causing spontaneous bonding failure1. It is also known that differences in CTE between ceramic, metal and metallic oxide may induce stress on the metal-ceramic interface11,12,24. There is no doubt that in order to guarantee esthetic results, the metal-ceramic bond strength is a basic factor because any failure with this bond may lead to an earlier removal of the restoration, regardless the success of initial results. However, there is no agreement regarding the adhesion mechanism between the metal and porcelain3,6,17,22. There are questions regarding the testing methods for evaluation of the actual strength of metal-ceramic bond, since a method that can accurately measure this property is as of yet unknown. Some authors state that there is no methodology capable of measuring only shear forces along the metal/porcelain interface3,13. In this study, the tensile load test with ceramic rings applied around metallic stems represents actual situations of metal-ceramic restorations with a larger esthetic covering of the process. No pre-heating was performed on the evaluated alloys, contradicting the respective manufacturer's indications of the Pors-on 4 alloy. The purpose of this criterion was to minimize the effect of the chemical interaction among the evaluated materials, thus enabling greater physical interaction activity of the components20,24. The manufacturer of the VB and VB2 alloys does not suggest pre-heating for single unit, only for multiple unit frameworks. However, according to a previous study14, the presence of Al (as Al2O3) and Be (as BeO) on the oxide layer of Ni-Cr alloy specimens submitted to pre-heating resulted to a better porcelain/metal bonding behavior. Therefore, it is possible that for each evaluated metallic substrate, the MCBS values could be improved if the pre-heating treatment was used. Therefore, it is possible that for each evaluated metallic substrate, the MCBS values could be improved if the manufacturer's recommendations were followed. By analyzing the loads involved in the metal-ceramic bond strength, there was no significant difference among five of the six evaluated metal-ceramic pairs. The association of alloy Pors-on 4 with ceramic IPS provided higher MCBS than the other combinations. On the other hand, no advantage was observed in using the alloy with Be. This is an important issue, considering the involved potential health risk. However, this result is different those of a previous study14, which performed pre-heating treatment of the alloys and reported that the presence of the Be reduced the oxide layer, hence promoting better metal-ceramic bonding. This fact might have occurred because in the present study the preheating treatment of the alloys was not performed, as previously explained, aiming at minimizing the effect of the chemical interaction among the evaluated materials. Although this higher difference is adverse for restoration longevity, the Pors-on 4/IPS pair presented the highest MCBS values (difference of 1.84 × 10-6°C-1) while the PD pair (difference of 2.6 × 10-6 °C-1) showed CMBS values without any significant difference in relation to the previously considered pairs, with CTE differences considered as more adequate. Therefore, in this case, it was not possible to correlate the two evaluated parameters. When building metal-ceramic pairs at high temperatures of opaque or dentin layer firing (900 to 950°C), porcelain is found in a softened state and it is adequately molded to the metallic substrate. From 600°C, when porcelain hardening occurs, the differences of the metal-ceramic pair can generate the occurrence of complex tensions, which makes it difficult to perceive the consequences of the genuine characteristic of the metal-ceramic bond. If the highest difference of CTE results in bonding failure was due to the occurrence of cracks11, it is possible that, in the case of PI, cracks did not occur and the porcelain maintained under tension presented the best results. However, it is possible that, if submitted to wear, a restoration made of this combination would undergo fracture due to the sum of chewing stress and the intrinsic stress of the metal-ceramic interface. In view of this possibility, the supposition that dynamic evaluations are perhaps better indicated to assess the actual quality and consequent longevity of metal-ceramic bond should be considered. It was difficult to compare the results of the present study to those obtained in other studies because different methods have been used to evaluated metal-ceramic bond strength. In the present study no pre-heating treatment was performed because it was not the aim of this study to add another variation factor, since not all of the manufacturers of studied alloys recommend pre-heating. Furthermore, the obtained results cannot be directly interpreted as clinically relevant, since factors such as the test geometry, the lack of a moist environment and lack of fatigue loading were not evaluated. Although the number of studied pairs was small, the goal of this work was not to generalize that there is not relation between MCBS and CTE differences, but rather to show that the differences were not the main factor and to emphasize the importance of chemical relation between the evaluated pairs. Additionally, this study aimed to demonstrate the problem. Further research should determine the importance of the bonding mechanisms and the compatibility of various metal-ceramic combinations. The data from these new studies might provide criteria for the rational selection of ceramics and alloys that have adequate bond strength for clinical use.

CONCLUSIONS

Considering the study methodology and limitations, it was concluded that: There was statistically significant difference only for the IPS ceramic/Pors-on 4 alloy pair, which showed the highest value of metal-ceramic bond strength. All other metal-ceramic pairs showed no significant differences. It was not possible to establish any correlation between the metal-ceramic bond strength values and CTE differences of the evaluated metal-ceramic pairs.
  22 in total

1.  Influence of contraction mismatch and cooling rate on flexural failure of PFM systems.

Authors:  J P Coffey; K J Anusavice; P H DeHoff; R B Lee; B Hojjatie
Journal:  J Dent Res       Date:  1988-01       Impact factor: 6.116

2.  New high-palladium casting alloys: 1. Overview and initial studies.

Authors:  A B Carr; W A Brantley
Journal:  Int J Prosthodont       Date:  1991 May-Jun       Impact factor: 1.681

3.  Effect of beryllium on the castability and resistance of ceramometal bonds in nickel-chromium alloys.

Authors:  O L Bezzon; M da G de Mattos; R F Ribeiro; J M Rollo
Journal:  J Prosthet Dent       Date:  1998-11       Impact factor: 3.426

4.  Surface analysis of porcelain fused to metal systems.

Authors:  Tony Johnson; Richard van Noort; Christopher W Stokes
Journal:  Dent Mater       Date:  2005-08-08       Impact factor: 5.304

5.  X-ray diffraction studies of oxidized high-palladium alloys.

Authors:  W A Brantley; Z Cai; E Papazoglou; J C Mitchell; S J Kerber; G P Mann; T L Barr
Journal:  Dent Mater       Date:  1996-11       Impact factor: 5.304

6.  Interactive effect of stress and temperature on creep of PFM alloys.

Authors:  K J Anusavice; C Shen; D Hashinger; S W Twiggs
Journal:  J Dent Res       Date:  1985-08       Impact factor: 6.116

7.  Comparative evaluation of ceramic-metal bond tests using finite element stress analysis.

Authors:  K J Anusavice; P H Dehoff; C W Fairhurst
Journal:  J Dent Res       Date:  1980-03       Impact factor: 6.116

8.  Bond strength of porcelain to dental alloys - an evaluation of two test methods.

Authors:  G Oilo; B Johansson; M Syverud
Journal:  Scand J Dent Res       Date:  1981-06

9.  Changes in physical and chemical properties of a dental palladium-silver alloy during metal-porcelain bonding.

Authors:  J Payan; G E Moya; J M Meyer; F Moya
Journal:  J Oral Rehabil       Date:  1986-07       Impact factor: 3.837

10.  New high-palladium casting alloys: Part 2. Effects of heat treatment and burnout temperature.

Authors:  A B Carr; Z Cai; W A Brantley; J C Mitchell
Journal:  Int J Prosthodont       Date:  1993 May-Jun       Impact factor: 1.681

View more
  3 in total

1.  Double veneering, low-temperature porcelain, and total glaze application methods to overcome failures of zirconia-based restorations.

Authors:  Cem Şahin
Journal:  Clin Oral Investig       Date:  2022-01-28       Impact factor: 3.573

2.  The Effect of Surface Processing on the Shear Strength of Cobalt-Chromium Dental Alloy and Ceramics.

Authors:  Liaisan Saleeva; Ramil Kashapov; Farid Shakirzyanov; Eduard Kuznetsov; Lenar Kashapov; Viktoriya Smirnova; Nail Kashapov; Gulshat Saleeva; Oskar Sachenkov; Rinat Saleev
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

3.  The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy.

Authors:  Mitra Farzin; Rashin Giti; Amin Asalforush-Rezaiye
Journal:  Materials (Basel)       Date:  2018-03-22       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.