Literature DB >> 19269789

Bone stress for a mini-implant close to the roots of adjacent teeth--3D finite element analysis.

M Motoyoshi1, S Ueno, K Okazaki, N Shimizu.   

Abstract

This study aimed to evaluate stress in the bone when an orthodontic mini-implant is close to the roots of adjacent teeth using finite element models (FEMs), and to investigate the causes of the high implant failure rate in the mandible. Four FEMs were used: the implant touches nothing; the implant touches the surface of the periodontal membrane; part of the screw thread is embedded in the periodontal membrane; and the implant touches the root. The effect of cortical bone thickness was evaluated using values of 1, 2 and 3 mm. Maximum stress value and stress distribution on the bone elements was determined. Maximum stress on the bone increased when the mini-implant was close to the root. When the implant touched the root, stress increased to 140 MPa or more, and bone resorption could be predicted. Stress was higher for a cortical bone thickness of 2 mm than for other thicknesses. Cortical bone 2 mm thick had a higher risk for bone resorption. A mandible with an average cortical bone thickness of 2 mm may have a higher risk for implant loosening than a maxilla with the same degree of root proximity, which may be related to the lower success rate in the mandible.

Mesh:

Substances:

Year:  2009        PMID: 19269789     DOI: 10.1016/j.ijom.2009.02.011

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  14 in total

1.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  Stability comparison between commercially available mini-implants and a novel design: part 1.

Authors:  Christine Hong; Haofu Lee; Richard Webster; Jinny Kwak; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

4.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

5.  Evaluation of Stress Pattern Caused by Mini-Implant in Mandibular Alveolar Bone with Different Angulations and Retraction Forces: A Three-Dimensional Finite Element Study.

Authors:  Manreet Sidhu; Vinay Kumar Chugh; Kuldeep Dmello; Anurag Mehta; Ankita Chugh; Pradeep Tandon
Journal:  Turk J Orthod       Date:  2020-07-18

6.  Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models.

Authors:  Takahiro Toriya; Toru Kitahara; Hiroto Hyakutake; Mitsugu Todo; Ichiro Takahashi
Journal:  Ann Biomed Eng       Date:  2022-09-27       Impact factor: 4.219

7.  Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis.

Authors:  Hyeon-Jung Lee; Kyung-Sook Lee; Min-Ji Kim; Youn-Sic Chun
Journal:  Korean J Orthod       Date:  2013-10-25       Impact factor: 1.372

8.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

9.  Biomechanical analysis of occlusal modes on the periodontal ligament while orthodontic force applied.

Authors:  Ming-Tzu Tsai; Heng-Li Huang; Shih-Guang Yang; Kuo-Chih Su; Lih-Jyh Fuh; Jui-Ting Hsu
Journal:  Clin Oral Investig       Date:  2021-03-04       Impact factor: 3.606

10.  Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants.

Authors:  Chin-Yun Pan; Pao-Hsin Liu; Yu-Chuan Tseng; Szu-Ting Chou; Chao-Yi Wu; Hong-Po Chang
Journal:  J Dent Sci       Date:  2019-07-20       Impact factor: 2.080

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.