Imaging performance of the hybrid pixel detectors XPAD3-S.

F Cassol Brunner1, J C Clemens, C Hemmer, C Morel.   

Abstract

Hybrid pixel detectors, originally developed for tracking particles in high-energy physics experiments, have recently been used in material sciences and macromolecular crystallography. Their capability to count single photons and to apply a threshold on the photon energy suggests that they could be optimal digital x-ray detectors in low energy beams such as for small animal computed tomography (CT). To investigate this issue, we have studied the imaging performance of photon counting hybrid pixel detectors based on the XPAD3-S chip. Two detectors are considered, connected either to a Si or to a CdTe sensor, the latter being of interest for its higher efficiency. Both a standard 'International Electrotechnical Commission' (IEC) mammography beam and a beam used for mouse CT results published in the literature are employed. The detector stability, linearity and noise are investigated as a function of the dose for several imaging exposures ( approximately 0.1-400 microGy). The perfect linearity of both detectors is confirmed, but an increase in internal noise for counting statistics higher than approximately 5000 photons has been found, corresponding to exposures above approximately 110 microGy and approximately 50 microGy for the Si and CdTe sensors, respectively. The noise power spectrum (NPS), the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are then measured for two energy threshold configurations (5 keV and 18 keV) and three doses ( approximately 3, 30 and 300 microGy), in order to obtain a complete estimation of the detector performances. In general, the CdTe sensor shows a clear superiority with a maximal DQE(0) of approximately 1, thanks to its high efficiency ( approximately 100%). The DQE of the Si sensor is more dependent on the radiation quality, due to the energy dependence of its efficiency its maximum is approximately 0.4 with respect to the softer radiation. Finally, we compare the XPAD3-S DQE with published curves of other digital devices in a similar radiation condition. The XPAD3-S/CdTe detector appears to be the best with the highest DQE at low frequency, although some improvements are expected to reduce the increase of noise with the counts statistics and to guarantee a better stability of the detector response.

Entities:  

Mesh:

Year:  2009        PMID: 19258683     DOI: 10.1088/0031-9155/54/6/024

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.

Authors:  N G Anderson; A P Butler; N J A Scott; N J Cook; J S Butzer; N Schleich; M Firsching; R Grasset; N de Ruiter; M Campbell; P H Butler
Journal:  Eur Radiol       Date:  2010-03-23       Impact factor: 5.315

2.  Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

Authors:  Srinivasan Vedantham; Suman Shrestha; Andrew Karellas; Linxi Shi; Matthew J Gounis; Ronaldo Bellazzini; Gloria Spandre; Alessandro Brez; Massimo Minuti
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Tracking Dynamics of Spontaneous Tumors in Mice Using Photon-Counting Computed Tomography.

Authors:  Franca Cassol; Loriane Portal; Sylvie Richelme; Mathieu Dupont; Yannick Boursier; Maria Arechederra; Nathalie Auphan-Anezin; Lionel Chasson; Caroline Laprie; Samantha Fernandez; Laure Balasse; Fabienne Lamballe; Rosanna Dono; Benjamin Guillet; Toby Lawrence; Christian Morel; Flavio Maina
Journal:  iScience       Date:  2019-10-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.