Literature DB >> 19258005

Development of a homogeneous immunoassay for the detection of angiotensin I in plasma using AlphaLISA acceptor beads technology.

Elizabeth Cauchon1, Susana Liu, M David Percival, Steve E Rowland, Daigen Xu, Christoph Binkert, Panja Strickner, Jean-Pierre Falgueyret.   

Abstract

Plasma renin activity (PRA) is a well-established biomarker for assessing the efficacy of various antihypertensive agents such as direct renin inhibitors, angiotensin receptor blockers, and angiotensin-converting enzyme inhibitors (ACEIs). PRA measurements are obtained through the detection and quantification of angiotensin I (Ang I) produced by the action of renin on its natural substrate angiotensinogen. The most accepted and reproducible method for PRA measurement uses an antibody capture Ang I methodology that employs specific antibodies that recognize and protect Ang I against angiotensinase activities contained in plasma. The amount of Ang I is then quantified by either radioimmunoassay (RIA) or enzyme immunoassay (EIA). In the current report, we describe the optimization of a novel homogeneous immunoassay based on the AlphaScreen technology for the detection and quantification of antibody-captured Ang I using AlphaLISA acceptor beads in buffer and in the plasma of various species (human, rat, and mouse). Ex vivo measurements of renin activity were performed using 10 microl or less of a reaction mixture, and concentrations as low as 1 nM Ang I were quantified. Titration curves obtained for the quantification of Ang I in buffer and plasma gave similar EC(50) values of 5.6 and 14.4 nM, respectively. Both matrices generated an equivalent dynamic range that varies from approximately 1 to 50 nM. Renin inhibitors have been successfully titrated and IC(50) values obtained correlated well with those obtained using EIA methodology (r(2)=0.80). This assay is sensitive, robust, fast, and less tedious than measurements performed using nonhomogeneous EIA. The AlphaLISA methodology is homogeneous, does not require wash steps prior to the addition of reagents, and does not generate radioactive waste.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19258005     DOI: 10.1016/j.ab.2009.02.031

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  9 in total

Review 1.  Blood-based diagnostics of traumatic brain injuries.

Authors:  Stefania Mondello; Uwe Muller; Andreas Jeromin; Jackson Streeter; Ronald L Hayes; Kevin K W Wang
Journal:  Expert Rev Mol Diagn       Date:  2011-01       Impact factor: 5.225

2.  Smartphone instrument for portable enzyme-linked immunosorbent assays.

Authors:  Kenneth D Long; Hojeong Yu; Brian T Cunningham
Journal:  Biomed Opt Express       Date:  2014-10-01       Impact factor: 3.732

3.  A fluorogenic near-infrared imaging agent for quantifying plasma and local tissue renin activity in vivo and ex vivo.

Authors:  Jun Zhang; Dorin V Preda; Kristine O Vasquez; Jeff Morin; Jeannine Delaney; Bagna Bao; M David Percival; Daigen Xu; Dan McKay; Michael Klimas; Bohumil Bednar; Cyrille Sur; David Z Gao; Karen Madden; Wael Yared; Milind Rajopadhye; Jeffrey D Peterson
Journal:  Am J Physiol Renal Physiol       Date:  2012-06-06

Review 4.  Recent developments in emerging microimmunoassays.

Authors:  Christine F Woolley; Mark A Hayes
Journal:  Bioanalysis       Date:  2013-01       Impact factor: 2.681

5.  Rapid, Automated, and Specific Immunoassay to Directly Measure Matrix Metalloproteinase-9-Tissue Inhibitor of Metalloproteinase-1 Interactions in Human Plasma Using AlphaLISA Technology: A New Alternative to Classical ELISA.

Authors:  Helena Pulido-Olmo; Elena Rodríguez-Sánchez; José Alberto Navarro-García; María G Barderas; Gloria Álvarez-Llamas; Julián Segura; Marisol Fernández-Alfonso; Luis M Ruilope; Gema Ruiz-Hurtado
Journal:  Front Immunol       Date:  2017-07-24       Impact factor: 7.561

Review 6.  Assays and technologies for developing proteolysis targeting chimera degraders.

Authors:  Xingui Liu; Xuan Zhang; Dongwen Lv; Yaxia Yuan; Guangrong Zheng; Daohong Zhou
Journal:  Future Med Chem       Date:  2020-05-20       Impact factor: 3.808

Review 7.  Small molecule inhibitors against PD-1/PD-L1 immune checkpoints and current methodologies for their development: a review.

Authors:  Chang Liu; Navindra P Seeram; Hang Ma
Journal:  Cancer Cell Int       Date:  2021-04-27       Impact factor: 5.722

8.  A homogeneous method for investigation of methylation-dependent protein-protein interactions in epigenetics.

Authors:  Amy M Quinn; Mark T Bedford; Alexsandra Espejo; Astrid Spannhoff; Christopher P Austin; Udo Oppermann; Anton Simeonov
Journal:  Nucleic Acids Res       Date:  2009-11-06       Impact factor: 16.971

9.  A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W.

Authors:  Biao Huang; Huixin Yu; Jiandong Bao; Manda Zhang; William L Green; Sing-Yung Wu
Journal:  Biomark Insights       Date:  2018-02-06
  9 in total