Literature DB >> 19250075

Early conduction disorders following percutaneous aortic valve replacement.

Valeria Calvi1, Euglena Puzzangara, Giusi Paola Pruiti, Sergio Conti, Angelo Di Grazia, Gian Paolo Ussia, Davide Capodanno, Corrado Tamburino.   

Abstract

BACKGROUND: Percutaneous aortic valve replacement (PAVR) may be an alternative therapy for patients with severe aortic stenosis who are denied valve surgery because of age and comorbidity. Data are few regarding the incidence of early conduction disorders (CD) after PAVR. We examined the incidence and characteristics of CD in the immediate postoperative period after PAVR, and the need for permanent pacemaker (PPM) implantation. METHODS AND
RESULTS: Between June 2007 and June 2008 30 patients (mean age = 82.1 +/- 8.5 years) underwent PAVR in our institution. The incidence of new, postoperative CD, diagnosed by 12-lead or 24-hour Holter electrocardiogram, was 68.0%. Left bundle branch block was the most common conduction abnormality, with an incidence of 45.8%. The incidence of complete atrioventricular block requiring PPM implantation was 20%.
CONCLUSIONS: We observed a higher incidence of early conduction disorders and need for PPM implantation after PAVR than generally reported after surgery. Whether this observation is clinically important requires larger prospective studies and follow up.

Entities:  

Mesh:

Year:  2009        PMID: 19250075     DOI: 10.1111/j.1540-8159.2008.02298.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  13 in total

1.  Transcatheter resection of the native aortic valve prior to endovalve implantation - A rational approach to reduce TAVI-induced complications.

Authors:  Parla Astarci; Pierre-Yves Etienne; Benoit Raucent; Xavier Bollen; Kahn Tranduy; David Glineur; Laurent Dekerchove; Philippe Noirhomme; Gébrine Elkhoury
Journal:  Ann Cardiothorac Surg       Date:  2012-07

2.  Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis.

Authors:  Valeria Calvi; Sergio Conti; Giusi Paola Pruiti; Davide Capodanno; Euglena Puzzangara; Donatella Tempio; Angelo Di Grazia; Gian Paolo Ussia; Corrado Tamburino
Journal:  J Interv Card Electrophysiol       Date:  2011-11-26       Impact factor: 1.900

3.  Clinical impact of a new left bundle branch block following TAVI implantation: 1-year results of the TAVIK cohort.

Authors:  Gerhard Schymik; Panagiotis Tzamalis; Peter Bramlage; Martin Heimeshoff; Alexander Würth; Rainer Wondraschek; Bernd-Dieter Gonska; Herbert Posival; Claus Schmitt; Holger Schröfel; Armin Luik
Journal:  Clin Res Cardiol       Date:  2014-11-12       Impact factor: 5.460

Review 4.  New conduction abnormalities after TAVI--frequency and causes.

Authors:  Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere
Journal:  Nat Rev Cardiol       Date:  2012-05-01       Impact factor: 32.419

5.  Conduction disorders after aortic valve replacement with rapid-deployment bioprostheses: early occurrence and one-year evolution.

Authors:  Augusto D'Onofrio; Chiara Tessari; Lorenzo Bagozzi; Federico Migliore; Claudia Filippini; Giorgia Cibin; Rita Pesce; Annalisa Francescato; Gino Gerosa
Journal:  Ann Cardiothorac Surg       Date:  2020-09

6.  One year follow-up of the multi-centre European PARTNER transcatheter heart valve study.

Authors:  Thierry Lefèvre; Ari Pieter Kappetein; Ernst Wolner; Patrick Nataf; Martyn Thomas; Volker Schächinger; Bernard De Bruyne; Hélène Eltchaninoff; Matthias Thielmann; Dominique Himbert; Mauro Romano; Patrick Serruys; Gerhard Wimmer-Greinecker
Journal:  Eur Heart J       Date:  2010-11-12       Impact factor: 29.983

7.  Evaluation of calcium loss after transcatheter aortic valve implantation.

Authors:  Thi Dan Linh Nguyen-Kim; Ayhan Sahin; Simon H Sündermann; Anna Winklehner; Jürg Grünenfelder; Maximilian Y Emmert; Willibald Maier; Lukas Altwegg; Thomas Frauenfelder; Volkmar Falk; André Plass
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-10-08

8.  Sudden Death After Transcatheter Aortic Valve Implantation. Are Bradyarrhythmias Always The Cause?

Authors:  Lida P Papavasileiou; Antonios Halapas; Michael Chrisocheris; Kyriakos Bellos; Nikolaos Bouboulis; Stratis Pattakos; Georgios Zervopoulos; Luca Santini; Konstantinos Spargias; Francesco Romeo; Giovanni Forleo; Theodoros Apostolopoulos
Journal:  J Atr Fibrillation       Date:  2015-10-31

9.  Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?

Authors:  Hassina Baraki; Ammar Al Ahmad; Stefan Jeng-Singh; Shunsuke Saito; Jan Dieter Schmitto; Bernhard Fleischer; Axel Haverich; Ingo Kutschka
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-08

10.  Characteristics of and current practice patterns of pacing for high-degree atrioventricular block after transcatheter aortic valve implantation in comparison to surgical aortic valve replacement.

Authors:  Naoki Misumida; Mariah Pagath; Gbolahan O Ogunbayo; Ryan E Wilson; Sun Moon Kim; Ahmed Abdel-Latif; Claude S Elayi
Journal:  Catheter Cardiovasc Interv       Date:  2018-10-09       Impact factor: 2.692