Literature DB >> 19249055

Evaluation of two approaches to characterise liquid chromatographic columns using pharmaceutical separations.

Sanja Dragovic1, Erik Haghedooren, Tamás Németh, I Murat Palabiyik, Jos Hoogmartens, Erwin Adams.   

Abstract

In this paper a comparison of two column characterisation systems is reported: the method based on the hydrophobic-subtraction model of Dolan and Snyder (HS method) versus the method developed at the Katholieke Universiteit Leuven (KUL method). Comparison was done for seven different pharmaceutical separations (fluoxetine, gemcitabine, erythromycin, tetracycline, tetracaine, amlodipine and bisacodyl), using a set of 59 columns. A ranking was built based on an F value (KUL) or F(s) value (HS) versus a (virtual) reference column. Both methods showed similar probabilities of ranking patterns. Correlation of the respective test parameters of both approaches was poor. Both methods are not perfect and do not match well, but anyhow yield results which allow, with a relatively high certainty, the selection of similar or dissimilar columns as compared to a reference column. An analyst that uses either of the two methods will end up with a similar probability to choose an adequate column. From a practical point of view, it must be noted that the KUL method is easier to use.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19249055     DOI: 10.1016/j.chroma.2009.02.023

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Evaluation of the identification power of RPLC analyses in the screening for drug compounds.

Authors:  Melanie Dumarey; Yvan Vander Heyden; Sarah C Rutan
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

2.  Development of the HPLC Method for Simultaneous Determination of Lidocaine Hydrochloride and Tribenoside Along with Their Impurities Supported by the QSRR Approach.

Authors:  Alina Plenis; Lucyna Konieczna; Natalia Miękus; Tomasz Bączek
Journal:  Chromatographia       Date:  2012-11-01       Impact factor: 2.044

3.  A visual approach to stationary phase selectivity classification based on the Snyder-Dolan Hydrophobic-Subtraction Model.

Authors:  Yu Zhang; Peter W Carr
Journal:  J Chromatogr A       Date:  2009-06-21       Impact factor: 4.759

4.  A simple method for HPLC retention time prediction: linear calibration using two reference substances.

Authors:  Lei Sun; Hong-Yu Jin; Run-Tao Tian; Ming-Juan Wang; Li-Na Liu; Liu-Ping Ye; Tian-Tian Zuo; Shuang-Cheng Ma
Journal:  Chin Med       Date:  2017-06-19       Impact factor: 5.455

5.  Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards.

Authors:  Qingjun Wang; Xinlan Yu; Lei Sun; Runtao Tian; Huaizhen He; Sicen Wang; Shuangcheng Ma
Journal:  Chin Med       Date:  2021-01-11       Impact factor: 5.455

6.  Chemometric evaluation of the column classification system during the pharmaceutical analysis of lamotrigine and its related substances.

Authors:  Jarosław Szulfer; Alina Plenis; Tomasz Bączek
Journal:  Anal Bioanal Chem       Date:  2013-06-28       Impact factor: 4.142

7.  Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

Authors:  Alina Plenis; Natalia Rekowska; Tomasz Bączek
Journal:  Int J Mol Sci       Date:  2016-01-21       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.