Literature DB >> 19248163

Quantitative measurement of blood flow dynamics in embryonic vasculature using spectral Doppler velocimetry.

Anjul Davis1, Joseph Izatt, Florence Rothenberg.   

Abstract

The biophysical effects of blood flow are known to influence the structure and function of adult cardiovascular systems. Similar effects on the maturation of the cardiovascular system have been difficult to directly and non-invasively measure due to the small size of the embryo. Optical coherence tomography (OCT) has been shown to provide high spatial and temporal structural imaging of the early embryonic chicken heart. We have developed an extension of Doppler OCT, called spectral Doppler velocimetry (SDV), that will enable direct, non-invasive quantification of blood flow and shear rate from the early embryonic cardiovascular system. Using this technique, we calculated volumetric flow rate and shear rate from chicken embryo vitelline vessels. We present blood flow dynamics and spatial velocity profiles from three different vessels in the embryo as well as measurements from the outflow tract of the embryonic heart tube. This technology can potentially provide spatial mapping of blood flow and shear rate in embryonic cardiovascular structures, producing quantitative measurements that can be correlated with gene expression and normal and abnormal morphology. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19248163      PMCID: PMC2918287          DOI: 10.1002/ar.20808

Source DB:  PubMed          Journal:  Anat Rec (Hoboken)        ISSN: 1932-8486            Impact factor:   2.064


  29 in total

1.  Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis.

Authors:  Jay R Hove; Reinhard W Köster; Arian S Forouhar; Gabriel Acevedo-Bolton; Scott E Fraser; Morteza Gharib
Journal:  Nature       Date:  2003-01-09       Impact factor: 49.962

Review 2.  Ultrasound biomicroscopy-Doppler in mouse cardiovascular development.

Authors:  Colin K L Phoon; Daniel H Turnbull
Journal:  Physiol Genomics       Date:  2003-06-24       Impact factor: 3.107

3.  Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system.

Authors:  Wei Luo; Daniel L Marks; Tyler S Ralston; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

4.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

Authors:  Robert Huber; Desmond C Adler; James G Fujimoto
Journal:  Opt Lett       Date:  2006-10-15       Impact factor: 3.776

Review 5.  Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell.

Authors:  Shu Chien
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-11-10       Impact factor: 4.733

6.  Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos.

Authors:  Jung Yeop Lee; Ho Seong Ji; Sang Joon Lee
Journal:  Physiol Meas       Date:  2007-09-18       Impact factor: 2.833

7.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

8.  High resolution imaging of in vivo cardiac dynamics using color Doppler optical coherence tomography.

Authors:  S Yazdanfar; M Kulkarni; J Izatt
Journal:  Opt Express       Date:  1997-12-22       Impact factor: 3.894

9.  High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography.

Authors:  T G van Leeuwen; M D Kulkarni; S Yazdanfar; A M Rollins; J A Izatt
Journal:  Opt Lett       Date:  1999-11-15       Impact factor: 3.776

Review 10.  Endothelial mechanotransduction, nitric oxide and vascular inflammation.

Authors:  D G Harrison; J Widder; I Grumbach; W Chen; M Weber; C Searles
Journal:  J Intern Med       Date:  2006-04       Impact factor: 8.989

View more
  29 in total

1.  Investigating in vivo airway wall mechanics during tidal breathing with optical coherence tomography.

Authors:  Claire Robertson; Sang-Won Lee; Yeh-Chan Ahn; Sari Mahon; Zhongping Chen; Matthew Brenner; Steven C George
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

2.  Measuring hemodynamics in the developing heart tube with four-dimensional gated Doppler optical coherence tomography.

Authors:  Michael W Jenkins; Lindsy Peterson; Shi Gu; Madhusudhana Gargesha; David L Wilson; Michiko Watanabe; Andrew M Rollins
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

3.  Laser speckle flowmetry method for measuring spatial and temporal hemodynamic alterations throughout large microvascular networks.

Authors:  Joshua K Meisner; Suna Sumer; Kelsey P Murrell; Timothy J Higgins; Richard J Price
Journal:  Microcirculation       Date:  2012-10       Impact factor: 2.628

4.  Trans-illuminated laser speckle imaging of collateral artery blood flow in ischemic mouse hindlimb.

Authors:  Joshua K Meisner; Jacqueline Niu; Suna Sumer; Richard J Price
Journal:  J Biomed Opt       Date:  2013-09       Impact factor: 3.170

5.  Assessment of strain and strain rate in embryonic chick heart in vivo using tissue Doppler optical coherence tomography.

Authors:  Peng Li; Aiping Liu; Liang Shi; Xin Yin; Sandra Rugonyi; Ruikang K Wang
Journal:  Phys Med Biol       Date:  2011-10-21       Impact factor: 3.609

6.  Live imaging of rat embryos with Doppler swept-source optical coherence tomography.

Authors:  Irina V Larina; Kenryo Furushima; Mary E Dickinson; Richard R Behringer; Kirill V Larin
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

7.  In vivo functional imaging of blood flow and wall strain rate in outflow tract of embryonic chick heart using ultrafast spectral domain optical coherence tomography.

Authors:  Peng Li; Xin Yin; Liang Shi; Sandra Rugonyi; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2012-09       Impact factor: 3.170

8.  Embryonic aortic arch hemodynamics are a functional biomarker for ethanol-induced congenital heart defects [Invited].

Authors:  Lindsy M Peterson; Shi Gu; Ganga Karunamuni; Michael W Jenkins; Michiko Watanabe; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

9.  Orientation-independent rapid pulsatile flow measurement using dual-angle Doppler OCT.

Authors:  Lindsy M Peterson; Shi Gu; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2014-01-15       Impact factor: 3.732

10.  Measurement of absolute blood flow velocity in outflow tract of HH18 chicken embryo based on 4D reconstruction using spectral domain optical coherence tomography.

Authors:  Zhenhe Ma; Aiping Liu; Xin Yin; Aaron Troyer; Kent Thornburg; Ruikang K Wang; Sandra Rugonyi
Journal:  Biomed Opt Express       Date:  2010-09-08       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.