Literature DB >> 18079871

High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography.

T G van Leeuwen1, M D Kulkarni, S Yazdanfar, A M Rollins, J A Izatt.   

Abstract

Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on interference signal demodulation at multiple frequencies, to extend the physiological relevance of CDOCT by increasing the dynamic range of measurable velocities to hundreds of millimeters per second. The physiologically important parameter of shear rate is also derived from CDOCT measurements. The measured flow-velocity profiles and shear-rate distributions correlate very well with theoretical predictions. The multiple demodulation technique, therefore, may be useful to monitor blood flow in vivo and to identify regions with high and low shear rates.

Entities:  

Year:  1999        PMID: 18079871     DOI: 10.1364/ol.24.001584

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  8 in total

1.  Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography.

Authors:  Chuanwu Xi; Daniel L Marks; Devang S Parikh; Lutgarde Raskin; Stephen A Boppart
Journal:  Proc Natl Acad Sci U S A       Date:  2004-05-10       Impact factor: 11.205

2.  Measurement of biofilm growth and local hydrodynamics using optical coherence tomography.

Authors:  Nicolás Weiss; Khalid El Tayeb El Obied; Jeroen Kalkman; Rob G H Lammertink; Ton G van Leeuwen
Journal:  Biomed Opt Express       Date:  2016-08-17       Impact factor: 3.732

3.  Embryonic aortic arch hemodynamics are a functional biomarker for ethanol-induced congenital heart defects [Invited].

Authors:  Lindsy M Peterson; Shi Gu; Ganga Karunamuni; Michael W Jenkins; Michiko Watanabe; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

4.  Longitudinal optical imaging of tumor metabolism and hemodynamics.

Authors:  Melissa C Skala; Andrew Fontanella; Lan Lan; Joseph A Izatt; Mark W Dewhirst
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

5.  Combined hyperspectral and spectral domain optical coherence tomography microscope for noninvasive hemodynamic imaging.

Authors:  Melissa C Skala; Andrew Fontanella; Hansford Hendargo; Mark W Dewhirst; Joseph A Izatt
Journal:  Opt Lett       Date:  2009-02-01       Impact factor: 3.776

6.  Quantitative measurement of blood flow dynamics in embryonic vasculature using spectral Doppler velocimetry.

Authors:  Anjul Davis; Joseph Izatt; Florence Rothenberg
Journal:  Anat Rec (Hoboken)       Date:  2009-03       Impact factor: 2.064

7.  4D shear stress maps of the developing heart using Doppler optical coherence tomography.

Authors:  Lindsy M Peterson; Michael W Jenkins; Shi Gu; Lee Barwick; Michiko Watanabe; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2012-10-31       Impact factor: 3.732

8.  GPU accelerated real-time multi-functional spectral-domain optical coherence tomography system at 1300 nm.

Authors:  Yan Wang; Christian M Oh; Michael C Oliveira; M Shahidul Islam; Arthur Ortega; B Hyle Park
Journal:  Opt Express       Date:  2012-07-02       Impact factor: 3.894

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.