Literature DB >> 1924778

High-resolution, short echo time MR imaging of the fingers and wrist with a local gradient coil.

E C Wong1, A Jesmanowicz, J S Hyde.   

Abstract

The many fibrous tissues of the wrist and hand have short T2s, and, because of the small size of the tissues, their magnetic resonance (MR) imaging necessitates use of the high spatial resolution obtainable with fields of view as small as 2 cm x 2 cm x 1 mm. The authors demonstrate that the use of a local xyz gradient coil, positioned off-center in a clinical MR imager to facilitate patient positioning, permits acquisition of high-resolution images in spin-echo (SE) and gradient-recalled-echo (GRE) sequences with echo time (TE) as short as 6 msec (SE) or 3 msec (GRE). The authors compare this method for obtaining high-resolution images with the alternative method of using normal gradient strengths and increased pulse duration. The effects on image quality of TE, bandwidth, gradient strength, and chemical shift artifacts are presented. Images obtained with the local gradient coil of the carpal tunnel, carpal bones, and proximal interphalangeal joint in healthy volunteers are shown.

Entities:  

Mesh:

Year:  1991        PMID: 1924778     DOI: 10.1148/radiology.181.2.1924778

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  High resolution MRI of the normal finger at 0.1 T: anatomic correlations.

Authors:  J L Drapé; A Constantinesco; S Arbogast; H Sick; R Wolfram-Gabel; B Brunot
Journal:  Surg Radiol Anat       Date:  1992       Impact factor: 1.246

2.  Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice.

Authors:  B Chronik; A Alejski; B K Rutt
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

Review 3.  [Closed injuries of the extensor hood of the metacarpophalangeal joint].

Authors:  K Ferlemann; H Zilch
Journal:  Unfallchirurgie       Date:  1997-12

Review 4.  Osteoarthritis and magnetic resonance imaging: potential and problems.

Authors:  C W Hutton; W Vennart
Journal:  Ann Rheum Dis       Date:  1995-04       Impact factor: 19.103

Review 5.  Sewer pipe, wire, epoxy, and finger tapping: the start of fMRI at the Medical College of Wisconsin.

Authors:  Peter A Bandettini
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

Review 6.  MRI of enthesitis of the appendicular skeleton in spondyloarthritis.

Authors:  Iris Eshed; Matthias Bollow; Dennis G McGonagle; Ai Lyn Tan; Christian E Althoff; Patrick Asbach; Kay-Geert A Hermann
Journal:  Ann Rheum Dis       Date:  2007-05-25       Impact factor: 19.103

7.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

8.  In vivo MRI of the human finger at 7 T.

Authors:  Elmar Laistler; Barbara Dymerska; Jürgen Sieg; Sigrun Goluch; Roberta Frass-Kriegl; Andre Kuehne; Ewald Moser
Journal:  Magn Reson Med       Date:  2017-03-10       Impact factor: 4.668

9.  Predicting in vivo MRI Gradient-Field Induced Voltage Levels on Implanted Deep Brain Stimulation Systems Using Neural Networks.

Authors:  M Arcan Erturk; Eric Panken; Mark J Conroy; Jonathan Edmonson; Jeff Kramer; Jacob Chatterton; S Riki Banerjee
Journal:  Front Hum Neurosci       Date:  2020-02-20       Impact factor: 3.169

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.