Literature DB >> 1290151

High resolution MRI of the normal finger at 0.1 T: anatomic correlations.

J L Drapé1, A Constantinesco, S Arbogast, H Sick, R Wolfram-Gabel, B Brunot.   

Abstract

MR images of the fingers are obtained in a 128 x 128 or 256 x 256 matrix format using a prototype of a mini imager dedicated to the hand. The vertical field of 0.1 T is provided by an electro-magnet with an air gap of 15 cm equipped with a single solenoidal coil. No Faraday cage is used. The maximum in plane pixel resolution of 100 mu is obtained for a field of view of 2.5 cm with a slice thickness of 2 mm. The identification of fine structures of the finger is demonstrated by the anatomical and histological correlations. This type of imager which is adapted to very limited field of views demonstrate that high resolution MRI of limb extremities can be achieved at 0.1 T.

Mesh:

Year:  1992        PMID: 1290151     DOI: 10.1007/bf01794763

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  19 in total

1.  High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition.

Authors:  T K Foo; F G Shellock; C E Hayes; J F Schenck; B E Slayman
Journal:  Radiology       Date:  1992-04       Impact factor: 11.105

2.  High resolution, high field magnetic resonance imaging of joints: unexpected features in proton images of cartilage.

Authors:  P R Cole; M K Jasani; B Wood; A J Freemont; G A Morris
Journal:  Br J Radiol       Date:  1990-11       Impact factor: 3.039

3.  Magnetic resonance imaging of a glomus tumor. A case report.

Authors:  L H Schneider; T B Bachow
Journal:  Orthop Rev       Date:  1991-03

Review 4.  High-resolution MR imaging with local coils.

Authors:  J B Kneeland; J S Hyde
Journal:  Radiology       Date:  1989-04       Impact factor: 11.105

5.  MR imaging of hand and wrist with a dedicated 0.1-T low-field imaging system.

Authors:  P Gries; A Constantinesco; B Brunot; A Facello
Journal:  Magn Reson Imaging       Date:  1991       Impact factor: 2.546

6.  Case report 466. Granulomatous tenosynovitis (left 3rd finger).

Authors:  G A Waggenspack; E G Amparo
Journal:  Skeletal Radiol       Date:  1988       Impact factor: 2.199

7.  MR imaging of the finger: correlation with normal anatomic sections.

Authors:  S J Erickson; J B Kneeland; W D Middleton; A Jesmanowicz; J Hyde; T L Lawson; W D Foley
Journal:  AJR Am J Roentgenol       Date:  1989-05       Impact factor: 3.959

8.  A comparison of saddle-shaped and solenoidal coils for magnetic resonance imaging.

Authors:  M Arakawa; L E Crooks; B McCarten; J C Hoenninger; J C Watts; L Kaufman
Journal:  Radiology       Date:  1985-01       Impact factor: 11.105

9.  Interdigital (Morton) neuroma: high-resolution MR imaging with a solenoid coil.

Authors:  S J Erickson; P B Canale; G F Carrera; J E Johnson; M J Shereff; J S Gould; J S Hyde; A Jesmanowicz
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

10.  High-resolution magnetic resonance imaging of the interphalangeal joints of the hand.

Authors:  M E Fry; R K Jacoby; C W Hutton; R E Ellis; M Phil; S Pittard; W Vennart
Journal:  Skeletal Radiol       Date:  1991       Impact factor: 2.199

View more
  2 in total

1.  Dedicated low-field MRI: a promising low cost-technique.

Authors:  S Arbogast-Ravier; F Xu; P Choquet; B Brunot; A Constantinesco
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

2.  MRI of the epidural space after gelatin/gadolinium venous injection.

Authors:  O Plaisant; G Cosnard; C Gillot; H Schill; J P Lassau
Journal:  Surg Radiol Anat       Date:  1994       Impact factor: 1.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.