Literature DB >> 19245860

Challenges of automated screening and differentiation of non-organ specific autoantibodies on HEp-2 cells.

Rico Hiemann1, Thomas Büttner, Thorsten Krieger, Dirk Roggenbuck, Ulrich Sack, Karsten Conrad.   

Abstract

Analysis of autoantibodies (AAB) by indirect immunofluorescence (IIF) remains the hallmark of diagnosing autoimmune diseases despite the introduction of multiplex techniques. Non-organ specific AAB are screened in routine diagnostics by IIF on HEp-2 cells. However, IIF results vary due to objective (e.g., cell fixation) and subjective factors (e.g., expert knowledge). Therefore, inter- and intralaboratory variance is relatively high. Standardisation of AAB testing by IIF remains a critical issue in and between routine laboratories and may be improved by automated interpretation systems. An overview of existing interpretation techniques will be given taking into account own data of the first fully automated reading system AKLIDES. The novel system provides fully automated reading of IIF images and software algorithms for the mathematical description of IIF AAB patterns. It can be used for screening and preclassification of non-organ specific AAB in routine diagnostics regarding systemic autoimmune and autoimmune liver diseases. Furthermore, this system paves the way for economic data processing of cell-based IIF assays and can contribute to the reduction of interlaboratory variance of AAB testing. More sophisticated pattern recognition algorithms and novel calibration systems will improve standardised quantifications of IIF image interpretation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19245860     DOI: 10.1016/j.autrev.2009.02.033

Source DB:  PubMed          Journal:  Autoimmun Rev        ISSN: 1568-9972            Impact factor:   9.754


  35 in total

Review 1.  The Clinical Relevance of Anti-DFS70 Autoantibodies.

Authors:  Karsten Conrad; Nadja Röber; Luis E C Andrade; Michael Mahler
Journal:  Clin Rev Allergy Immunol       Date:  2017-04       Impact factor: 8.667

2.  Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus.

Authors:  Chelsea Bentow; Gabriella Lakos; Rachel Rosenblum; Cassandra Bryant; Andrea Seaman; Michael Mahler
Journal:  Immunol Res       Date:  2015-02       Impact factor: 2.829

3.  Mobile phone radiofrequency exposure has no effect on DNA double strand breaks (DSB) in human lymphocytes.

Authors:  Elisa Danese; Giuseppe Lippi; Ruggero Buonocore; Marco Benati; Chiara Bovo; Chiara Bonaguri; Gian Luca Salvagno; Giorgio Brocco; Dirk Roggenbuck; Martina Montagnana
Journal:  Ann Transl Med       Date:  2017-07

4.  Antinuclear antibodies detection: A comparative study between automated recognition and conventional visual interpretation.

Authors:  ZhiYan Li; RuiLin Han; ZhenLin Yan; LiJuan Li; ZhenRu Feng
Journal:  J Clin Lab Anal       Date:  2018-07-20       Impact factor: 2.352

5.  Deoxyribonuclease activity of polyclonal IgGs: a putative serological marker in patients with spondyloarthritides.

Authors:  Alena V Kundzer; Margarita V Volkova; Dimitrios P Bogdanos; Stefan Rödiger; Peter Schierack; I Generalov; Georgy A Nevinsky; Dirk Roggenbuck
Journal:  Immunol Res       Date:  2013-07       Impact factor: 2.829

6.  Evaluation of an automated chemiluminescent immunoassay kit for antinuclear antibodies in autoimmune diseases.

Authors:  Yaron Zafrir; Boris Gilburd; Marina Garcia Carrasco; Shaye Kivity; María Sánchez-Castañón; Marcos López-Hoyos; Mathilda Mandel; Magdalena Szmyrka; Yehuda Shoenfeld; Nancy Agmon-Levin
Journal:  Immunol Res       Date:  2013-07       Impact factor: 2.829

7.  The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test.

Authors:  M Infantino; F Meacci; V Grossi; M Manfredi; M Benucci; M Merone; P Soda
Journal:  Immunol Res       Date:  2017-02       Impact factor: 2.829

8.  A novel automated indirect immunofluorescence autoantibody evaluation.

Authors:  Shaye Kivity; Boris Gilburd; Nancy Agmon-Levin; Marina Garcia Carrasco; Yaron Tzafrir; Yael Sofer; Matilda Mandel; Thomas Buttner; Dirk Roggenbuck; Marco Matucci-Cerinic; Katalin Danko; Marcos López Hoyos; Yehuda Shoenfeld
Journal:  Clin Rheumatol       Date:  2011-11-05       Impact factor: 2.980

9.  Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests.

Authors:  Karl Egerer; Dirk Roggenbuck; Rico Hiemann; Max-Georg Weyer; Thomas Büttner; Boris Radau; Rosemarie Krause; Barbara Lehmann; Eugen Feist; Gerd-Rüdiger Burmester
Journal:  Arthritis Res Ther       Date:  2010-03-09       Impact factor: 5.156

10.  Design of a Computer-Assisted System to Automatically Detect Cell Types Using ANA IIF Images for the Diagnosis of Autoimmune Diseases.

Authors:  Chung-Chuan Cheng; Chun-Feng Lu; Tsu-Yi Hsieh; Yaw-Jen Lin; Jin-Shiuh Taur; Yung-Fu Chen
Journal:  J Med Syst       Date:  2015-08-20       Impact factor: 4.460

View more