Literature DB >> 19244948

Aspheric intraocular lens selection based on corneal wavefront.

Mark Packer1, I Howard Fine, Richard S Hoffman.   

Abstract

PURPOSE: To determine the feasibility of selectively targeting zero total postoperative spherical aberration by selecting the best fit aspheric intraocular lens (IOL) based on preoperative topographically derived corneal spherical aberration.
METHODS: Candidates for cataract surgery were offered selection of aspheric IOLs based on corneal spherical aberration. The target postoperative total wavefront spherical aberration Z4,0 was set at zero. Corneal topographic spherical aberration Z4,0 was measured at the 6-mm optical zone, and one of three aspheric IOLs was chosen so the arithmetic sum of the corneal spherical aberration and pseudophakic spherical aberration came closest to zero. Postoperatively, total ocular wavefront was measured and statistical analysis performed to ascertain the accuracy of customized aspheric IOL selection.
RESULTS: Thirty eyes of 18 patients were available for analysis. The SofPort Advanced Optics (Bausch & Lomb) lens was implanted in 1 eye, the AcrySof IQ (Alcon Laboratories Inc) in 11 eyes, and the Tecnis Z9000 or Z9002 (Advanced Medical Optics [AMO]) in 18 eyes. Total postoperative ocular spherical aberration for the entire population measured -0.013+/-0.072 microm (SofPort: +0.025 microm; AcrySof IQ: +0.010+/-0.053 microm; and Tecnis: -0.015+/-0.052 microm [P=.22]). For the entire population, mean absolute predictive error measured 0.058+/-0.056 microm (SofPort: 0.040 microm; AcrySof IQ: 0.052+/-0.040 microm; and Tecnis: 0.063+/-0.066 microm [P=.631).
CONCLUSIONS: Customized selection of aspheric IOLs based on corneal wavefront is feasible and produces favorable results compared with studies of unselected patient populations implanted with aspheric IOLs.

Entities:  

Mesh:

Year:  2009        PMID: 19244948     DOI: 10.3928/1081597X-20090101-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  10 in total

1.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery.

Authors:  Tarfah M Al-Sayyari; Samah M Fawzy; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2014-06-25

3.  Clinical study of customized aspherical intraocular lens implants.

Authors:  Lie-Xi Jia; Zhao-Hui Li
Journal:  Int J Ophthalmol       Date:  2014-10-18       Impact factor: 1.779

4.  Corneal spherical aberration in Saudi population.

Authors:  Tarfah M Al-Sayyari; Samah M Fawzy; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2014-03-18

5.  Changes in spherical aberration after various corneal surface ablation techniques.

Authors:  Hyun Seok Ahn; Jae Lim Chung; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  Korean J Ophthalmol       Date:  2013-02-28

6.  Aspheric versus Spherical Posterior Chamber Intraocular Lenses.

Authors:  Mohammad-Reza Jafarinasab; Sepehr Feizi; Ahmad-Reza Baghi; Hossein Ziaie; Mehdi Yaseri
Journal:  J Ophthalmic Vis Res       Date:  2010-10

7.  Distribution of corneal spherical aberration in a Tanzanian population.

Authors:  Hiroki Asano; Takahiro Hiraoka; Yusuke Seki; Teppei Shibata; Hiromi Osada; Takanori Saruta; Natsuko Hatsusaka; Fukumi Fujikake; Yoshiaki Tabata; Cellina Mhina; Anna Sanyiwa; Tetsuro Oshika; Hiroshi Sasaki
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

8.  Comparison of corneal elevation and pachymetry measurements made by two state of the art corneal tomographers with different measurement principles.

Authors:  Simon Schröder; Achim Langenbucher; Jens Schrecker
Journal:  PLoS One       Date:  2019-10-16       Impact factor: 3.240

9.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04

10.  Comparison of retinal image quality with spherical and customized aspheric intraocular lenses.

Authors:  Huanqing Guo; Alexander V Goncharov; Chris Dainty
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.