PURPOSE: To evaluate the differences in enhancement of the abdominal solid organ and the major vessel on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) obtained with gadolinium ethoxybenzyldiethylenetriamine pentaacetic acid (Gd-EOB-DTPA: EOB) and gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) in the same patients.
MATERIALS AND METHODS: A total of 13 healthy volunteers underwent repeat assessments of abdominal MR examinations with DCE-MRI using either Gd-DTPA at a dose of 0.1 mmol/kg body weight or EOB at a dose of 0.025 mmol/kg body weight. DCE images were obtained at precontrast injection and in the arterial phase (AP: 25 seconds), portal phase (PP: 70 seconds), and equilibrium phase (EP: 3 minutes). The signal intensities (SIs) of liver at AP, PP, and EP; the SIs of spleen, renal cortex, renal medulla, pancreas, adrenal gland, aorta at AP; and the SIs of portal vein and inferior vena cava (IVC) at PP were defined using region-of-interest measurements, and were used for calculation of signal intensity ratio (SIR).
RESULTS: The mean SIRs of liver (0.195+/-0.140), spleen (1.35+/-0.353), renal cortex (1.58+/-0.517), renal medulla (0.548+/-0.259), pancreas (0.540+/-0.183), adrenal gland (1.04+/-0.405), and aorta (2.44+/-0.648) at AP as well as the mean SIRs of portal vein (1.85+/-0.477) and IVC (1.16+/-0.187) at PP in the EOB images were significantly lower than those (0.337+/-0.200, 1.99+/-0.443, 2.01+/-0.474, 0.742+/-0.336, 0.771+/-0.227, 1.26+/-0.442, 3.22+/-1.20, 2.73+/-0.429, and 1.68+/-0.366, respectively) in the Gd-DTPA images (P<0.05 each). There was no significant difference in mean SIR of liver at PP between EOB (0.529+/-0.124) and Gd-DTPA (0.564+/-0.139). Conversely, the mean SIR of liver at EP was significantly higher with EOB (0.576+/-0.167) than with Gd-DTPA (0.396+/-0.093) (P<0.001).
CONCLUSION: Lower arterial vascular and parenchymal enhancement with Gd-EOB, as compared with Gd-DTPA, may require reassessment of its dose, despite the higher late venous phase liver parenchymal enhancement. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19243060     DOI: 10.1002/jmri.21689

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  36 in total

1.  Magnetic resonance imaging: Review of imaging techniques and overview of liver imaging.

Authors:  Santhi Maniam; Janio Szklaruk
Journal:  World J Radiol       Date:  2010-08-28

2.  Effect of hepatobiliary uptake of Gd-EOB-DTPA on the hepatic venous phase of dynamic magnetic resonance imaging on a 3.0-T apparatus: comparison between Gd-EOB-DTPA and Gd-DTPA.

Authors:  Yasunari Fujinaga; Ayumi Ohya; Tsuyoshi Matsushita; Masahiro Kurozumi; Kazuhiko Ueda; Yoshihiro Kitou; Hitoshi Ueda; Masumi Kadoya
Journal:  Jpn J Radiol       Date:  2011-10-19       Impact factor: 2.374

3.  Does transient arterial-phase respiratory-motion-related artifact impact on diagnostic performance? An intra-patient comparison of extracellular gadolinium versus gadoxetic acid.

Authors:  Jordi Rimola; Anna Darnell; Ernest Belmonte; Victor Sapena; Carla Caparroz; Neus Llarch; Maria Reig; Alejandro Forner; Jordi Bruix; Carmen Ayuso
Journal:  Eur Radiol       Date:  2020-06-30       Impact factor: 5.315

4.  Enhancement patterns and pseudo-washout of hepatic haemangiomas on gadoxetate disodium-enhanced liver MRI.

Authors:  Bohyun Kim; Jae Ho Byun; Hyoung Jung Kim; Hyung Jin Won; So Yeon Kim; Yong Moon Shin; Pyo Nyun Kim
Journal:  Eur Radiol       Date:  2015-05-02       Impact factor: 5.315

5.  The value of contrast-enhanced dynamic and diffusion-weighted MR imaging for distinguishing benign and malignant splenic masses.

Authors:  Seo-Youn Choi; Seong Hyun Kim; Kyung Mi Jang; Tae Wook Kang; Kyoung Doo Song; Ji Yoon Moon; Yoon-Hyeong Choi; Bo Ra Lee
Journal:  Br J Radiol       Date:  2016-05-10       Impact factor: 3.039

6.  Modified CAIPIRINHA-VIBE without view-sharing on gadoxetic acid-enhanced multi-arterial phase MR imaging for diagnosing hepatocellular carcinoma: comparison with the CAIPIRINHA-Dixon-TWIST-VIBE.

Authors:  Seung Baek Hong; Nam Kyung Lee; Suk Kim; Hyeong Il Seo; Hyun Sung Kim; Dong Uk Kim; Tae Un Kim; Hwa Seong Ryu
Journal:  Eur Radiol       Date:  2019-04-16       Impact factor: 5.315

7.  Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution: Gd-EOB-DTPA versus Gd-DTPA in vivo.

Authors:  Yasunari Fujinaga; Hitoshi Ueda; Yoshihiro Kitou; Yoshinori Tsukahara; Yukiko Sugiyama; Masumi Kadoya
Journal:  Jpn J Radiol       Date:  2012-11-20       Impact factor: 2.374

Review 8.  Magnetic resonance imaging of the cirrhotic liver in the era of gadoxetic acid.

Authors:  Francesco Agnello; Marco Dioguardi Burgio; Dario Picone; Federica Vernuccio; Giuseppe Cabibbo; Lydia Giannitrapani; Adele Taibbi; Antonino Agrusa; Tommaso Vincenzo Bartolotta; Massimo Galia; Roberto Lagalla; Massimo Midiri; Giuseppe Brancatelli
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

Review 9.  Preoperative evaluation of colorectal cancer using CT colonography, MRI, and PET/CT.

Authors:  Shigeyoshi Kijima; Takahiro Sasaki; Koichi Nagata; Kenichi Utano; Alan T Lefor; Hideharu Sugimoto
Journal:  World J Gastroenterol       Date:  2014-12-07       Impact factor: 5.742

10.  Liver perfusion in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI): comparison of enhancement in Gd-BT-DO3A and Gd-EOB-DTPA in normal liver parenchyma.

Authors:  Hanke J Schalkx; Marijn van Stralen; Kenneth Coenegrachts; Maurice A A J van den Bosch; Charlotte S van Kessel; Richard van Hillegersberg; Karel J van Erpecum; Helena M Verkooijen; Josien P W Pluim; Wouter B Veldhuis; Maarten S van Leeuwen
Journal:  Eur Radiol       Date:  2014-07-05       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.