Literature DB >> 19242055

Fully 4D list-mode reconstruction applied to respiratory-gated PET scans.

N Grotus1, A J Reader, S Stute, J C Rosenwald, P Giraud, I Buvat.   

Abstract

(18)F-fluoro-deoxy-glucose ((18)F-FDG) positron emission tomography (PET) is one of the most sensitive and specific imaging modalities for the diagnosis of non-small cell lung cancer. A drawback of PET is that it requires several minutes of acquisition per bed position, which results in images being affected by respiratory blur. Respiratory gating techniques have been developed to deal with respiratory motion in the PET images. However, these techniques considerably increase the level of noise in the reconstructed images unless the acquisition time is increased. The aim of this paper is to evaluate a four-dimensional (4D) image reconstruction algorithm that combines the acquired events in all the gates whilst preserving the motion deblurring. This algorithm was compared to classic ordered subset expectation maximization (OSEM) reconstruction of gated and non-gated images, and to temporal filtering of gated images reconstructed with OSEM. Two datasets were used for comparing the different reconstruction approaches: one involving the NEMA IEC/2001 body phantom in motion, the other obtained using Monte-Carlo simulations of the NCAT breathing phantom. Results show that 4D reconstruction reaches a similar performance in terms of the signal-to-noise ratio (SNR) as non-gated reconstruction whilst preserving the motion deblurring. In particular, 4D reconstruction improves the SNR compared to respiratory-gated images reconstructed with the OSEM algorithm. Temporal filtering of the OSEM-reconstructed images helps improve the SNR, but does not achieve the same performance as 4D reconstruction. 4D reconstruction of respiratory-gated images thus appears as a promising tool to reach the same performance in terms of the SNR as non-gated acquisitions while reducing the motion blur, without increasing the acquisition time.

Entities:  

Mesh:

Year:  2009        PMID: 19242055     DOI: 10.1088/0031-9155/54/6/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

Authors:  Moulay Ali Nassiri; Jean-François Carrier; Philippe Després
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

Review 2.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

3.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

Review 4.  Management of respiratory motion in PET/computed tomography: the state of the art.

Authors:  Audrey Pépin; Joël Daouk; Pascal Bailly; Sébastien Hapdey; Marc-Etienne Meyer
Journal:  Nucl Med Commun       Date:  2014-02       Impact factor: 1.690

5.  Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging.

Authors:  Héctor Espinós-Morató; David Cascales-Picó; Marina Vergara; Ángel Hernández-Martínez; José María Benlloch Baviera; María José Rodríguez-Álvarez
Journal:  Sensors (Basel)       Date:  2021-04-08       Impact factor: 3.576

6.  On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework.

Authors:  Adam L Kesner; Paul J Schleyer; Florian Büther; Martin A Walter; Klaus P Schäfers; Phillip J Koo
Journal:  EJNMMI Phys       Date:  2014-06-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.