Literature DB >> 19241084

Standard bipolar diathermy forceps vessel ligation is safe in thyroidectomy.

James Russell Tysome1, Rudaina Hassan, Jeremy Davis.   

Abstract

Bleeding is a major complication of thyroid surgery. A retrospective study was performed comparing the outcomes of patients undergoing thyroid surgery where bipolar diathermy with standard bipolar forceps was used for vessel ligation (n = 64) compared to clamp-and-tie (n = 89). Fewer drains were inserted and patients were discharged earlier when standard bipolar diathermy was used for vessel ligation in hemithyroidectomies (P < 0.001). Complication rates were similar. The use of bipolar diathermy with standard forceps for vessel ligation in thyroid surgery has been shown to be as safe and effective as the clamp-and-tie technique, while resulting in earlier patient discharge. This technique is cost-efficient as it provides the advantage of reduced inpatient stay reported using bipolar vessel sealing devices or the harmonic scalpel, but without the additional expense.

Entities:  

Mesh:

Year:  2009        PMID: 19241084     DOI: 10.1007/s00405-009-0925-8

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  26 in total

1.  A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy.

Authors:  Carlos Cordón; Rafael Fajardo; Jaqueline Ramírez; Miguel F Herrera
Journal:  Surgery       Date:  2005-03       Impact factor: 3.982

2.  The use of Ligasure Vessel Sealing System in thyroid surgery.

Authors:  Vassilios A Lachanas; Emmanuel P Prokopakis; Antonios A Mpenakis; Alexander D Karatzanis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-03       Impact factor: 3.497

3.  Is lack of placement of drains after thyroidectomy with central neck dissection safe? A prospective, randomized study.

Authors:  Seung Won Lee; Eun Chang Choi; Yong Man Lee; Jae Yong Lee; Shi Chan Kim; Yoon Woo Koh
Journal:  Laryngoscope       Date:  2006-09       Impact factor: 3.325

4.  Reduction of Thermal Spread and Tissue Adherence with an Irrigating Bipolar Grasper

Authors: 
Journal:  J Am Assoc Gynecol Laparosc       Date:  1996-08

5.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.

Authors:  Allan E Siperstein; Eren Berber; Ebru Morkoyun
Journal:  Arch Surg       Date:  2002-02

6.  Minimal damage during endoscopic latissimus dorsi muscle mobilization with the harmonic scalpel.

Authors:  H Inaba; Y Kaneko; T Ohtsuka; M Ezure; K Tanaka; K Ueno; S Takamoto
Journal:  Ann Thorac Surg       Date:  2000-05       Impact factor: 4.330

7.  Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique.

Authors:  Jan Franko; Karen J Kish; Christopher M Pezzi; Ho Pak; John S Kukora
Journal:  Am Surg       Date:  2006-02       Impact factor: 0.688

8.  Does draining the neck affect morbidity following thyroid surgery?

Authors:  G Schoretsanitis; J Melissas; E Sanidas; M Christodoulakis; J G Vlachonikolis; D D Tsiftsis
Journal:  Am Surg       Date:  1998-08       Impact factor: 0.688

9.  A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy.

Authors:  Mehmet Kilic; Mehmet Keskek; Tamer Ertan; Omer Yoldas; Aydin Bilgin; Mahmut Koc
Journal:  Adv Ther       Date:  2007 May-Jun       Impact factor: 3.845

10.  Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation.

Authors:  Andreas Manouras; Haridimos Markogiannakis; Athanasios S Koutras; Pantelis T Antonakis; Panagiotis Drimousis; Emmanuel E Lagoudianakis; Panagiotis Kekis; Michael Genetzakis; Konstantinos Koutsoumanis; Ioannis Bramis
Journal:  Am J Surg       Date:  2008-01       Impact factor: 2.565

View more
  2 in total

1.  Outcomes of Capsular Dissection Technique with Use of Bipolar Electrocautery in Total Thyroidectomy: A Rural Tertiary Center Experience.

Authors:  Amal T Das; S B Prakash; V Priyadarshini
Journal:  J Clin Diagn Res       Date:  2016-12-01

2.  Safety and Efficacy of Bipolar Radiofrequency Ablation Device in Hemostasis during Thyroidectomy in Comparison with Ultrasonic Scalpel: A Comparative Study.

Authors:  Sadeq G Kadem; Majid H Alabbood
Journal:  Indian J Endocrinol Metab       Date:  2019 Jan-Feb
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.