Literature DB >> 1923402

Tooth length determination: a review.

A Katz1, A Tamse, A Y Kaufman.   

Abstract

Tooth length determination is a crucial step in endodontic treatment. Until the late 1970s, tooth length determination was based mainly on radiographic interpretation. The advent of apex locators, which identify the difference in the electrical resistance between the root canal and the periodontal membrane, ushered in a new era for measuring tooth length. However, the accuracy of these devices has been questioned. Pertinent literature is discussed with the aim of providing information on the development of the concept, techniques, and devices for tooth length determination.

Mesh:

Year:  1991        PMID: 1923402     DOI: 10.1016/0030-4220(91)90169-d

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  9 in total

1.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

2.  Precision of multi-frequency electronic apex locators.

Authors:  Roy George
Journal:  Evid Based Dent       Date:  2016-09

3.  In vivo assessment of the impedance ratio method used in electronic foramen locators.

Authors:  Marcos V H Rambo; Humberto R Gamba; Gustavo B Borba; Joaquim M Maia; Carlos A S Ramos
Journal:  Biomed Eng Online       Date:  2010-09-06       Impact factor: 2.819

4.  A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.

Authors:  Irfana Khursheed; Ruchika Bansal; Tajinder Bansal; Harkanwal Preet Singh; Madhulika Yadav; K Jetender Reddy
Journal:  Dent Res J (Isfahan)       Date:  2014-01

5.  A clinical correlation between stature and posterior tooth length.

Authors:  Smitha Reddy; Bhuvan Shome; Jayaprakash Patil; Pradeep Koppolu
Journal:  Pan Afr Med J       Date:  2017-01-16

6.  Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study.

Authors:  Monisha Parshotam Khatri; Sheetal B Ghivari; Madhu Pujar; Reshma Faras; Pallavi Gopeshetti; Amulya Vanti
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

7.  In Vitro Comparison of Raypex 6 and Endopilot Using a Novel, Computer-Aided Measurement System, for Determining the Working Length.

Authors:  David Christofzik; Falk Schwendicke; Christian Flörke; Alexander Härtl; Christof Dörfer; Birte Größner-Schreiber
Journal:  PLoS One       Date:  2015-08-03       Impact factor: 3.240

8.  Evaluation of Two New Electronic Apex-Locator-Controlled Handpieces Using a NiTi Rotary File: An In Vitro Study.

Authors:  Kiumarz Nazarimoghadam; Hossein Labaf
Journal:  J Dent (Tehran)       Date:  2013-11-30

9.  Comparison of Accuracy in Determining the Root Canal Working Length by Using Two Generations of Apex Locators - An In Vitro Study.

Authors:  Kapil Golvankar; Mohammed Abdul Kader; Abhilash Abdul Latheef; Ahamed Babiker Mohammed Ali; Shahabe Saquib Abullais; Mohammed Sibagathullah
Journal:  Open Access Maced J Med Sci       Date:  2019-09-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.