Literature DB >> 19231774

Intraoperative cone-beam computed tomography in oral and maxillofacial surgery using a C-arm prototype: first clinical experiences after treatment of zygomaticomaxillary complex fractures.

Philipp Pohlenz1, Felix Blake, Marco Blessmann, Ralf Smeets, Christian Habermann, Philipp Begemann, Rainer Schmelzle, Max Heiland.   

Abstract

PURPOSE: To describe the first clinical applications of intraoperative cone-beam computed tomography with an integrated flat-panel detector in oral and maxillofacial surgery after surgical treatment of zygomaticomaxillary complex fractures PATIENTS AND METHODS: Nine cone-beam computed tomography datasets of patients with zygomaticomaxillary complex fractures were intraoperatively acquired using a mobile isocentric C-arm (PowerMobil; Siemens Medical Solutions, Erlangen, Germany), including a flat-panel detector. Datasets based on 400, 200, and 100 fluoroscopic images were performed with different tube currents (4.6 mA, 3.3 mA, 2.3 mA, 1.2 mA, and 0.5 mA) and a current tube voltage of 100 kV. Postprocessing resulted in 15 different datasets available for comparison with corresponding preoperative computed tomography datasets. Four oral and maxillofacial surgeons and 2 experienced radiologists evaluated each dataset regarding noise, transition, and the delimitation of landmarks.
RESULTS: All examinations were successfully performed. Reconstructed datasets showed high-resolution images of all midfacial osseous structures in near-computed tomography quality. Regarding high-contrast structures, detailed analyses of datasets acquired in this study suggest that the parameters 400 projections, 1.2 mA, and 100 kV are sufficient. In terms of soft-tissue visualization, a higher level of mA seems preferable.
CONCLUSIONS: The tested prototype predicts a new era in cone-beam computed tomography imaging. The integration of a flat-panel detector will overcome the limitations of current available systems. The size of the field of view is increased allowing regularly the visualization of the whole facial skeleton. Particularly in cases of open reduction of unilateral fractures, the assessment of symmetry is of clinical value.

Entities:  

Mesh:

Year:  2009        PMID: 19231774     DOI: 10.1016/j.joms.2008.06.086

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  6 in total

1.  Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans.

Authors:  Simon Veldhoen; Maximilian Schöllchen; H Hanken; C Precht; F O Henes; G Schön; H D Nagel; U Schumacher; M Heiland; G Adam; M Regier
Journal:  Eur Radiol       Date:  2016-05-11       Impact factor: 5.315

2.  Intraoperative imaging and navigation with mobile cone-beam CT in maxillofacial surgery.

Authors:  Quentin Goguet; Sang Hwy Lee; Julie Longis; Pierre Corre; Hélios Bertin
Journal:  Oral Maxillofac Surg       Date:  2019-05-16

3.  Ratio of Simple versus Comminuted Lateral Wall Fractures of the Orbit.

Authors:  Ruth J Barta; Warren Schubert
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-09-24

Review 4.  Trauma of the midface.

Authors:  Thomas S Kühnel; Torsten E Reichert
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22

5.  Preliminary outcomes of the surgical navigation system combined with intraoperative three-dimensional C-arm computed tomography for zygomatico-orbital fracture reconstruction.

Authors:  Yu-Ying Chu; Jia-Ruei Yang; Bo-Ru Lai; Han-Tsung Liao
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.379

6.  3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

Authors:  Harley H L Chan; Jeffrey H Siewerdsen; Allan Vescan; Michael J Daly; Eitan Prisman; Jonathan C Irish
Journal:  PLoS One       Date:  2015-09-02       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.