Literature DB >> 19228639

Comparative evaluation of the Iris iQ200 body fluid module with manual hemacytometer count.

Teanya J Walker1, Lydia D Nelson, Brian W Dunphy, Danna M Anderson, Thomas S Kickler.   

Abstract

Manual cerebrospinal fluid (CSF) and body fluid cell counts done using a hemacytometer are labor-intensive and time-consuming. The automated Iris iQ200 with the Body Fluids Module (Iris Diagnostics, Chatsworth, CA) counts RBCs and nucleated cells in CSF and other body fluids using flow cell digital imaging. We compared the cell counts from the iQ200 and the hemacytometer. CSF and body fluid samples were first analyzed in duplicate using the Neubauer hemacytometer. We then counted the samples on the iQ200. CSF samples for RBC counts of 0 to 6.7 x 10(5)/microL and nucleated cell counts of 0 to 1,707/microL resulted in r = 0.996 and r = 0.998, respectively. Body fluid samples for RBC counts of 0 to 2.7 x 10(5)/microL and nucleated cell counts of 0 to 1.1 x 10(4)/microL resulted in r = 0.988 and r = 0.987, respectively. Day-to-day precision with quality control yielded coefficients of variation of 12.5% and 13.3% for RBC counts and 9.4% and 12.3% for nucleated cell counts. Linearity studies yielded slopes of 0.99 and 1.010 for RBC and nucleated cell counts, respectively. The results from the iQ200 correlate well with the manual hemacytometer method.

Mesh:

Year:  2009        PMID: 19228639     DOI: 10.1309/AJCPSVG4POONQQ1R

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Continuous ambulatory peritoneal dialysis, ascitic and pleural body fluids evaluation with the Mindray BC-6800 hematology analyzer.

Authors:  Oscar Fuster; Belinda Andino; Amparo Pardo; Begoña Laiz
Journal:  J Clin Lab Anal       Date:  2017-04-26       Impact factor: 2.352

2.  Evaluation of Sysmex XN-1000 hematology analyzer for cell count and screening of malignant cells of serous cavity effusion.

Authors:  Weiyi Xu; Qian Yu; Lixia Xie; Baode Chen; Ling Zhang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

3.  A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment.

Authors:  Jiwon Lee; Younggeun Cho; Han-Sung Kim; Hee Jung Kang; Miyoung Kim; Young Kyung Lee
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

4.  A laboratory modification to testicular sperm preparation technique improves spermatogenic cell yield.

Authors:  Sinan Ozkavukcu; Ebru Ibis; Sule Kizil; Suheyla Isbacar; Kaan Aydos
Journal:  Asian J Androl       Date:  2014 Nov-Dec       Impact factor: 3.285

  4 in total