Literature DB >> 19224713

Flexible nerve stimulation electrode with iridium oxide sputtered on liquid crystal polymer.

Kevin Wang1, Chung-Chiun Liu, Dominique M Durand.   

Abstract

Current electrode designs require flexible substrates that absorb little moisture and provide large charge injection capability. Sputtered iridium oxide films have superior charge injection capabilities versus noble metals and can adhere to various substrates. Liquid crystal polymers (LCPs) have very little water absorption compared to other flexible substrates. Therefore, the combination of sputtered iridium oxide film on LCP substrate was studied using 50 Hz, 100 micros duration, and 10 mA biphasic current waveforms for 700 h at 67 degrees C in bicarbonate buffer saline. Scanning electron micrograph analysis showed no delamination and approximately 1% of electrode material was lost to the bicarbonate buffer. The charge injection limit and the cathodic charge storage capacity within the water window were 4.6 +/- 1.0 and 31.5 +/-6.6 mC/cm2, respectively. Additional electrochemical analysis revealed significant charge imbalance attributed to oxygen reduction within the water window. These results, along with the flexible, chemically inert, and biocompatible substrate, indicate that sputtered iridium oxide films on LCP could become the method of choice for flexible substrate nerve electrodes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19224713      PMCID: PMC2738844          DOI: 10.1109/TBME.2008.926691

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode.

Authors:  Dustin J Tyler; Dominique M Durand
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2002-12       Impact factor: 3.802

Review 2.  A review of portable FES-based neural orthoses for the correction of drop foot.

Authors:  Gerard M Lyons; Thomas Sinkjaer; Jane H Burridge; David J Wilcox
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2002-12       Impact factor: 3.802

3.  Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates.

Authors:  Sayed A M Marzouk
Journal:  Anal Chem       Date:  2003-03-15       Impact factor: 6.986

4.  Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation.

Authors:  Stuart F Cogan; Andrew A Guzelian; William F Agnew; Ted G H Yuen; Douglas B McCreery
Journal:  J Neurosci Methods       Date:  2004-08-30       Impact factor: 2.390

5.  Selective activation of small motor axons by quasi-trapezoidal current pulses.

Authors:  Z P Fang; J T Mortimer
Journal:  IEEE Trans Biomed Eng       Date:  1991-02       Impact factor: 4.538

Review 6.  Deep brain stimulation for neurologic and neuropsychiatric disorders.

Authors:  Thomas Wichmann; Mahlon R Delong
Journal:  Neuron       Date:  2006-10-05       Impact factor: 17.173

7.  Comprehensive Cyclic Voltammetry Characterization of AIROF Microelectrodes.

Authors:  Z Hu; P Troyk; S Cogan
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

8.  Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes.

Authors:  S F Cogan; T D Plante; J Ehrlich
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

Review 9.  The use of electrical devices for the treatment of bladder dysfunction: a review of methods.

Authors:  Michael R van Balken; Henk Vergunst; Bart L H Bemelmans
Journal:  J Urol       Date:  2004-09       Impact factor: 7.450

Review 10.  Functional electrical stimulation in tetraplegic patients to restore hand function.

Authors:  Gregory G Degnan; Tyler C Wind; Elizabeth V Jones; Richard F Edlich
Journal:  J Long Term Eff Med Implants       Date:  2002
View more
  6 in total

1.  Analysis of Pressure Variations in a Low-Pressure Nickel-Hydrogen Battery - Part 1.

Authors:  B K Purushothaman; J S Wainright
Journal:  J Power Sources       Date:  2012-05-15       Impact factor: 9.127

2.  Contribution of oxygen reduction to charge injection on platinum and sputtered iridium oxide neural stimulation electrodes.

Authors:  Stuart F Cogan; Julia Ehrlich; Timothy D Plante; Marcus D Gingerich; Douglas B Shire
Journal:  IEEE Trans Biomed Eng       Date:  2010-05-27       Impact factor: 4.538

Review 3.  Advances in Materials for Recent Low-Profile Implantable Bioelectronics.

Authors:  Yanfei Chen; Yun-Soung Kim; Bryan W Tillman; Woon-Hong Yeo; Youngjae Chun
Journal:  Materials (Basel)       Date:  2018-03-29       Impact factor: 3.623

Review 4.  Flexible Liquid Crystal Polymer Technologies from Microwave to Terahertz Frequencies.

Authors:  Zepeng Zhou; Wenqing Li; Jun Qian; Weihong Liu; Yiming Wang; Xijian Zhang; Qinglei Guo; Yevhen Yashchyshyn; Qingpu Wang; Yanpeng Shi; Yifei Zhang
Journal:  Molecules       Date:  2022-02-16       Impact factor: 4.411

5.  Nanofibrous PEDOT-Carbon Composite on Flexible Probes for Soft Neural Interfacing.

Authors:  Venkata Suresh Vajrala; Valentin Saunier; Lionel G Nowak; Emmanuel Flahaut; Christian Bergaud; Ali Maziz
Journal:  Front Bioeng Biotechnol       Date:  2021-11-26

6.  Towards smart self-clearing glaucoma drainage device.

Authors:  Hyunsu Park; Amir Hossein Raffiee; Simon W M John; Arezoo M Ardekani; Hyowon Lee
Journal:  Microsyst Nanoeng       Date:  2018-11-05       Impact factor: 7.127

  6 in total