Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry.

P J Muench1, A S Meigooni, R Nath, W L McLaughlin.   

Abstract

There is a new radiochromic film, a highly uniform, thin (100-microns) detector whose sensitive layer (6 microns thick) changes from colorless to blue by dye polymerization without processing, upon exposure to ionizing radiation. Because the dose gradients around brachytherapy sources are steep, the high spatial resolution offered by film dosimetry is an advantage over other detectors such as thermoluminescent dosimeters (TLDs). This compares the photon energy dependence of the sensitivities of GafChromic film, silver halide verification film (Kodak X-Omat V Film), and lithium fluoride TLDs (Harshaw), over the photon energy range 28 keV to 1.7 MeV, which is of interest in brachytherapy. Sensitivity of the radiochromic film is observed to decrease by about 30% as effective photon energy decreases from 1710 keV (4-MV x rays) to 28 keV (60-kV x rays, 2-mm A1 filter). In contrast, the sensitivity of verification film increases by 980% and that of LiF TLDs increases by 41%. The variation of the sensitivity of radiochromic film with photon energy is considerably less than that for silver halide film and similar to that for LiF TLDs, but in the opposite direction. Radiochromic film, like LIF TLDs, does not exhibit the drastic sensitivity changes below 127 keV that silver halide film exhibits. Dose distribution in the immediate vicinity of a high activity (370 GBq) brachytherapy 192Ir source has been mapped using radiochromic film and is presented to illustrate the applicability of this new technology to brachytherapy dosimetry.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1921886     DOI: 10.1118/1.596630

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

2.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Dose distribution verification for GYN brachytherapy using EBT Gafchromic film and TG-43 calculation.

Authors:  Somayeh Gholami; Hamid Reza Mirzaei; Ali Jabbary Arfaee; Ramin Jaberi; Hassan Ali Nedaie; Seied Rabi Mahdavi; Eftekhar Rajab Bolookat; Ali S Meigooni
Journal:  Rep Pract Oncol Radiother       Date:  2016-07-18

4.  Evaluation of gafchromic EBT film for intensity modulated radiation therapy dose distribution verification.

Authors:  A Sankar; P G Goplakrishna Kurup; V Murali; Komanduri M Ayyangar; R Mothilal Nehru; J Velmurugan
Journal:  J Med Phys       Date:  2006-04

5.  Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.

Authors:  Sharifeh A Dini; Rafiq A Koona; John R Ashburn; Ali S Meigoonia
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

6.  High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction.

Authors:  Heeteak Chung; Bart Lynch; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

7.  Plasmonic nanoparticles tuned thermal sensitive photonic polymer for biomimetic chameleon.

Authors:  Yang Yan; Lin Liu; Zihe Cai; Jiwen Xu; Zhou Xu; Di Zhang; Xiaobin Hu
Journal:  Sci Rep       Date:  2016-08-09       Impact factor: 4.379

8.  Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.

Authors:  Paule M Charland; Indrin J Chetty; Shigeru Yokoyama; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

9.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

10.  A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners.

Authors:  G Thomas; R Y L Chu; Frank Rabe
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.