Literature DB >> 19216272

Biomechanical comparison of different surface modifications for dental implants.

Stephen J Ferguson1, Jens D Langhoff, Katrin Voelter, Brigitte von Rechenberg, Dieter Scharnweber, Susanne Bierbaum, Matthias Schnabelrauch, Armin R Kautz, Vinzenz M Frauchiger, Thomas L Mueller, G Harry van Lenthe, Falko Schlottig.   

Abstract

PURPOSE: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design.
MATERIALS AND METHODS: Dental implants with the same geometry but with 6 different surface treatments were tested in vivo in a sheep model (pelvis). Peri-implant bone density and removal torque were compared at 2, 4, and 8 weeks after implantation. Implant surfaces tested were: sandblasted and acid-etched titanium (Ti), sandblasted and etched zirconia, Ti coated with calcium phosphate (CaP), Ti modified via anodic plasma-chemical treatment (APC), bisphosphonate-coated Ti (Ti + Bisphos), and Ti coated with collagen containing chondroitin sulfate (CS).
RESULTS: All dental implants were well integrated at the time of sacrifice. There were no significant differences observed in peri-implant bone density between implant groups. After 8 weeks of healing, removal torque values for Ti, Ti + CaP, Ti + Bisphos, and Ti + collagen + CS were significantly higher than those for zirconia and Ti + APC.
CONCLUSIONS: Whereas the sandblasted/acid-etched Ti implant can still be considered the reference standard surface for dental implants, functional surface modifications such as bisphosphonate or collagen coating seem to enhance early peri-implant bone formation and should be studied further.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19216272

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  20 in total

1.  Clinical evaluation of anodized surface implants submitted to a counter torque of 25 ncm after 60 days of osseointegration: study in humans.

Authors:  Rafael Manfro; Marcelo Carlos Bortoluzzi; Vinícius Fabris; Carlos Nelson Elias; Vera Cavalcanti de Araújo
Journal:  J Maxillofac Oral Surg       Date:  2013-09-13

2.  The effects of early osseointegration in different implant sites in rabbit tibias.

Authors:  Mingdeng Rong; Andi Zhu; Zehong Guo; Lei Zhou; Shaobing Li; Haibin Lu; Xueyang Zhang
Journal:  J Mater Sci Mater Med       Date:  2013-02-21       Impact factor: 3.896

3.  The evaluation of prepared microgroove pattern by femtosecond laser on alumina-zirconia nano-composite for endosseous dental implant application.

Authors:  Moluk Aivazi; Mohammad Hossein Fathi; Farahnaz Nejatidanesh; Vajihesadat Mortazavi; Batoul HashemiBeni; Jukka Pekka Matinlinna; Omid Savabi
Journal:  Lasers Med Sci       Date:  2016-09-28       Impact factor: 3.161

4.  Osseointegration and biocompatibility of different metal implants--a comparative experimental investigation in sheep.

Authors:  Michael Plecko; Christine Sievert; Daniel Andermatt; Robert Frigg; Peter Kronen; Karina Klein; Stefan Stübinger; Katja Nuss; Alexander Bürki; Stephen Ferguson; Ulrich Stoeckle; Brigitte von Rechenberg
Journal:  BMC Musculoskelet Disord       Date:  2012-03-08       Impact factor: 2.362

5.  Effect of local zoledronate on implant osseointegration in a rat model.

Authors:  David A Back; Stephan Pauly; Lisa Rommel; Norbert P Haas; Gerhard Schmidmaier; Britt Wildemann; Stefan H Greiner
Journal:  BMC Musculoskelet Disord       Date:  2012-03-22       Impact factor: 2.362

Review 6.  Oral Tissue Interactions and Cellular Response to Zirconia Implant-Prosthetic Components: A Critical Review.

Authors:  Marcel F Kunrath; Saurabh Gupta; Felice Lorusso; Antonio Scarano; Sammy Noumbissi
Journal:  Materials (Basel)       Date:  2021-05-25       Impact factor: 3.623

Review 7.  Functionalization of biomaterial surfaces using artificial extracellular matrices.

Authors:  Susanne Bierbaum; Vera Hintze; Dieter Scharnweber
Journal:  Biomatter       Date:  2012 Jul-Sep

Review 8.  Zirconia in dental implantology: A review.

Authors:  Abhishek Apratim; Prashanti Eachempati; Kiran Kumar Krishnappa Salian; Vijendra Singh; Saurabh Chhabra; Sanket Shah
Journal:  J Int Soc Prev Community Dent       Date:  2015 May-Jun

9.  Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae.

Authors:  Nam-Seok Kang; Lin-Jie Li; Sung-Am Cho
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

10.  A systematic review on the effect of inorganic surface coatings in large animal models and meta-analysis on tricalcium phosphate and hydroxyapatite on periimplant bone formation.

Authors:  Jeanne-Marie Damerau; Susanne Bierbaum; Daniel Wiedemeier; Paula Korn; Ralf Smeets; Gregor Jenny; Johanna Nadalini; Bernd Stadlinger
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2021-07-16       Impact factor: 3.405

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.