Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

Gabriele E Pecora1, Rolando Ceccarelli, Marco Bonelli, Harold Alexander, John L Ricci.   

Abstract

INTRODUCTION: A tapered dental implant (Laser-Lok [LL] surface treatment) with a 2 mm wide collar, that has been laser micromachined in the lower 1.5 mm to preferentially accomplish bone and connective tissue attachment while inhibiting epithelial downgrowth, was evaluated in a prospective, controlled, multicenter clinical trial. MATERIALS: Data are reported at measurement periods from 1 to 37 months postoperative for 20 pairs of implants in 15 patients. The implants are placed adjacent to machined collar control implants of the same design. Measurement values are reported for bleeding index, plaque index, probing depth, and crestal bone loss.
RESULTS: No statistical differences are measured for either bleeding or plaque index. At all measurement periods there are significant differences in the probing depths and the crestal bone loss differences are significant after 7 months (P < 0.001). At 37 months the mean probing depth is 2.30 mm and the mean crestal bone loss is 0.59 mm for LL versus 3.60 and 1.94 mm, respectively, for control implant. Also, comparing results in the mandible versus those in the maxilla demonstrates a bigger difference (control implant - LL) in the mean in crestal bone loss and probing depth in the maxilla. However, this result was not statistically significant. DISCUSSION: The consistent difference in probing depth between LL and control implant demonstrates the formation of a stable soft-tissue seal above the crestal bone. LL limited the crestal bone loss to the 0.59 mm range as opposed to the 1.94 mm crestal bone loss reported for control implant. The LL implant was found to be comparable with the control implant in safety endpoints plaque index and sulcular bleeding index. There is a nonstatistically significant suggestion that the LL crestal bone retention superiority is greater in the maxilla than the mandible.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19212238     DOI: 10.1097/ID.0b013e31818c5a6d

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  10 in total

1.  The effect of Er,Cr:YSGG laser irradiation on titanium discs with microtextured surface morphology.

Authors:  Esra Ercan; Celal Candirli; Tuna Arin; Levent Kara; Cihan Uysal
Journal:  Lasers Med Sci       Date:  2013-05-07       Impact factor: 3.161

Review 2.  Where is dentistry in regenerative medicine?

Authors:  John L Ricci; Louis Terracio
Journal:  Int Dent J       Date:  2011-08       Impact factor: 2.607

3.  Morphology, proliferation, and gene expression of gingival fibroblasts on Laser-Lok, titanium, and zirconia surfaces.

Authors:  Nasrin Esfahanizadeh; Sara Motalebi; Niloufar Daneshparvar; Nasrin Akhoundi; Shahin Bonakdar
Journal:  Lasers Med Sci       Date:  2016-03-30       Impact factor: 3.161

4.  Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans.

Authors:  Gerhard Iglhaut; Sebastian Salomon; Tobias Fretwurst; Peter Thomas; Janina Endres; Selina Kessler; Burkhard Summer
Journal:  Int J Implant Dent       Date:  2021-05-25

5.  The peri-implant esthetics: An unforgettable entity.

Authors:  Sangeeta Dhir
Journal:  J Indian Soc Periodontol       Date:  2011-04

Review 6.  Impact of Dental Implant Surface Modifications on Osseointegration.

Authors:  Ralf Smeets; Bernd Stadlinger; Frank Schwarz; Benedicta Beck-Broichsitter; Ole Jung; Clarissa Precht; Frank Kloss; Alexander Gröbe; Max Heiland; Tobias Ebker
Journal:  Biomed Res Int       Date:  2016-07-11       Impact factor: 3.411

7.  Preparation of micro/nanopatterned gelatins crosslinked with genipin for biocompatible dental implants.

Authors:  Reika Makita; Tsukasa Akasaka; Seiichi Tamagawa; Yasuhiro Yoshida; Saori Miyata; Hirofumi Miyaji; Tsutomu Sugaya
Journal:  Beilstein J Nanotechnol       Date:  2018-06-11       Impact factor: 3.649

Review 8.  Latest Trends in Surface Modification for Dental Implantology: Innovative Developments and Analytical Applications.

Authors:  Francesca Accioni; Juan Vázquez; Manuel Merinero; Belén Begines; Ana Alcudia
Journal:  Pharmaceutics       Date:  2022-02-21       Impact factor: 6.321

9.  Does the Laser-Microtextured Short Implant Collar Design Reduce Marginal Bone Loss in Comparison with a Machined Collar?

Authors:  B Alper Gultekin; Ali Sirali; Pinar Gultekin; Serdar Yalcin; Eitan Mijiritsky
Journal:  Biomed Res Int       Date:  2016-08-31       Impact factor: 3.411

10.  Histological differences in the adherence of connective tissue to laser-treated abutments and standard abutments for dental implants. An experimental pilot study in humans.

Authors:  M Blázquez-Hinarejos; R Ayuso-Montero; J-M Álvarez-López; M-C Manzanares-Céspedes; J López-López
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-11-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.