Literature DB >> 34031775

Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans.

Gerhard Iglhaut1,2, Sebastian Salomon3, Tobias Fretwurst4, Peter Thomas5, Janina Endres5, Selina Kessler5, Burkhard Summer5.   

Abstract

OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants.
MATERIAL AND METHODS: A total of 40 patients with one titanium implant, half of them (n=20) provided with a M abutment (control group) and the other half (n=20) with LMS abutments (test group), were included in the study. Clinical parameters pocket probing depth (PD), full-mouth plaque score (FMPS), radiographic bone loss (RBL), clinical attachment level (CAL), mucosal recession (MR), bleeding on probing (BOP), and width of keratinized mucosa (KM) were evaluated. The peri-implant sulcus fluid was analyzed for cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10 via flow cytometry.
RESULTS: Clinical evaluation demonstrated no significant difference of PD (mean LMS = 3.50 mm/SD 0.95 mm vs mean M = 3.45 mm/SD 0.76 mm (p=0.855)), MR (mean LMS = 0.30 mm/SD 0.57 mm vs mean M = 0.35 mm/SD 0.67 mm (p=0.801)), CAL (mean LMS = 3.60 mm/SD 1.14 mm vs mean M = 3.55 mm/SD 0.89 mm (p=0.878)), and KM (mean LMS = 2.03 mm/SD 1.08 mm vs mean M = 2.13 mm/SD 0.92 mm (p=0.754)) between LMS and M abutments. LMS abutments showed less BOP than M abutments (26.7% vs 30.8%), but statistically not significant (p = 0.2235). Radiographic bone loss (mean LMS = 0.22 mm/SD 0.44 mm vs mean M = 0.59 mm/SD 0.49 mm) was reduced in the test group in comparison with the control group (p=0.016). In the collected PICF, the levels of pro-inflammatory cytokines IL-1α (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p=0.968)) and IL-1β (median LMS = 60.43 pg/ml vs M = 83.11 pg/ml (p=0.4777)) were lower, and the levels of IL-6 (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p<0.0001)) were significantly lower in the test group. In contrast, the levels of IL-8 (median LMS = 255.7 pg/ml vs M = 178.7 pg/ml (p=0.3306)) were higher in the test group, though not significantly. The levels of anti-inflammatory IL-10 were significantly increased in the test group (LMS median = 0.555 pg/ml vs M median = 0.465 pg/ml (p=0.0365)). IL-1β showed a significant correlation to radiologic bone loss (p=0.0024). The other variables IL-1α, IL-6, IL-8, and IL-10 had no significant correlation to radiological bone loss.
CONCLUSION: Within the limitations of this study, titanium implants provided with laser-microtextured surface abutments seem to demonstrate less pro-inflammatory and more anti-inflammatory activity and to show reduced radiographic bone loss compared to machined titanium abutments. CLINICAL RELEVANCE: The use of laser-microtextured surface abutments might have the potential to support peri-implant tissue health.

Entities:  

Keywords:  Cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10; Laser-microtextured surface abutments; Machined abutments; Peri-implant crestal bone loss; Peri-implant crevicular fluid (PICF)

Year:  2021        PMID: 34031775     DOI: 10.1186/s40729-021-00329-8

Source DB:  PubMed          Journal:  Int J Implant Dent        ISSN: 2198-4034


  45 in total

1.  10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients.

Authors:  Daniel Buser; Simone F M Janner; Julia-Gabriela Wittneben; Urs Brägger; Christoph A Ramseier; Giovanni E Salvi
Journal:  Clin Implant Dent Relat Res       Date:  2012-12       Impact factor: 3.932

Review 2.  Therapy of peri-implantitis: a systematic review.

Authors:  Sotirios Kotsovilis; Ioannis K Karoussis; Maria Trianti; Ioannis Fourmousis
Journal:  J Clin Periodontol       Date:  2008-05-11       Impact factor: 8.728

3.  Impact of abutment microstructure and insertion depth on crestal bone changes at nonsubmerged titanium implants with platform switch.

Authors:  Frank Schwarz; Ilja Mihatovic; Vladimir Golubovich; Alex Schär; Martin Sager; Jürgen Becker
Journal:  Clin Oral Implants Res       Date:  2014-08-30       Impact factor: 5.977

4.  Periimplant diseases: where are we now?--Consensus of the Seventh European Workshop on Periodontology.

Authors:  Niklaus P Lang; Tord Berglundh
Journal:  J Clin Periodontol       Date:  2011-03       Impact factor: 8.728

5.  Probe penetration in periodontal and peri-implant tissues. An experimental study in the beagle dog.

Authors:  Ingemar Abrahamsson; Claudio Soldini
Journal:  Clin Oral Implants Res       Date:  2006-12       Impact factor: 5.977

6.  Probing depth at implants and teeth. An experimental study in the dog.

Authors:  I Ericsson; J Lindhe
Journal:  J Clin Periodontol       Date:  1993-10       Impact factor: 8.728

7.  Cytokines expression in saliva and peri-implant crevicular fluid of patients with peri-implant disease.

Authors:  Fabio José Persegani Olivar Fonseca; Mario Moraes Junior; Eduardo José Veras Lourenço; Daniel de Moraes Teles; Carlos Marcelo Figueredo
Journal:  Clin Oral Implants Res       Date:  2012-10-29       Impact factor: 5.977

8.  Differential response of human gingival fibroblasts to titanium- and titanium-zirconium-modified surfaces.

Authors:  M Gómez-Florit; J M Ramis; R Xing; S Taxt-Lamolle; H J Haugen; S P Lyngstadaas; M Monjo
Journal:  J Periodontal Res       Date:  2013-08-06       Impact factor: 4.419

9.  A 10-year prospective study of single tooth implants placed in the anterior maxilla.

Authors:  Klaus Gotfredsen
Journal:  Clin Implant Dent Relat Res       Date:  2009-08-06       Impact factor: 3.932

10.  Crestal bone loss and oral implants.

Authors:  Tomas Albrektsson; Daniel Buser; Lars Sennerby
Journal:  Clin Implant Dent Relat Res       Date:  2012-11-30       Impact factor: 3.932

View more
  1 in total

1.  Human Gingival Fibroblast and Osteoblast Behavior on Groove-Milled Zirconia Implant Surfaces.

Authors:  Mariana Brito da Cruz; Joana Faria Marques; Neusa Silva; Sara Madeira; Óscar Carvalho; Filipe Samuel Silva; João Caramês; António Mata
Journal:  Materials (Basel)       Date:  2022-03-28       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.