Gerhard Iglhaut1,2, Sebastian Salomon3, Tobias Fretwurst4, Peter Thomas5, Janina Endres5, Selina Kessler5, Burkhard Summer5. 1. Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center of Freiburg, Freiburg, Germany. dr.iglhaut@t-online.de. 2. Private Center of Oral Surgery, Bahnhofstrasse 20, 87700, Memmingen, Germany. dr.iglhaut@t-online.de. 3. Private Dental Center, Frastanz, Austria. 4. Department of Oral and Craniomaxillofacial Surgery, Translational Implantology, Center for Dental Medicine, University Medical Center of Freiburg, Freiburg, Germany. 5. Department of Dermatology and Allergology, Ludwig Maximilians University of Munich, Munich, Germany.
Abstract
OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants. MATERIAL AND METHODS: A total of 40 patients with one titanium implant, half of them (n=20) provided with a M abutment (control group) and the other half (n=20) with LMS abutments (test group), were included in the study. Clinical parameters pocket probing depth (PD), full-mouth plaque score (FMPS), radiographic bone loss (RBL), clinical attachment level (CAL), mucosal recession (MR), bleeding on probing (BOP), and width of keratinized mucosa (KM) were evaluated. The peri-implant sulcus fluid was analyzed for cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10 via flow cytometry. RESULTS: Clinical evaluation demonstrated no significant difference of PD (mean LMS = 3.50 mm/SD 0.95 mm vs mean M = 3.45 mm/SD 0.76 mm (p=0.855)), MR (mean LMS = 0.30 mm/SD 0.57 mm vs mean M = 0.35 mm/SD 0.67 mm (p=0.801)), CAL (mean LMS = 3.60 mm/SD 1.14 mm vs mean M = 3.55 mm/SD 0.89 mm (p=0.878)), and KM (mean LMS = 2.03 mm/SD 1.08 mm vs mean M = 2.13 mm/SD 0.92 mm (p=0.754)) between LMS and M abutments. LMS abutments showed less BOP than M abutments (26.7% vs 30.8%), but statistically not significant (p = 0.2235). Radiographic bone loss (mean LMS = 0.22 mm/SD 0.44 mm vs mean M = 0.59 mm/SD 0.49 mm) was reduced in the test group in comparison with the control group (p=0.016). In the collected PICF, the levels of pro-inflammatory cytokines IL-1α (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p=0.968)) and IL-1β (median LMS = 60.43 pg/ml vs M = 83.11 pg/ml (p=0.4777)) were lower, and the levels of IL-6 (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p<0.0001)) were significantly lower in the test group. In contrast, the levels of IL-8 (median LMS = 255.7 pg/ml vs M = 178.7 pg/ml (p=0.3306)) were higher in the test group, though not significantly. The levels of anti-inflammatory IL-10 were significantly increased in the test group (LMS median = 0.555 pg/ml vs M median = 0.465 pg/ml (p=0.0365)). IL-1β showed a significant correlation to radiologic bone loss (p=0.0024). The other variables IL-1α, IL-6, IL-8, and IL-10 had no significant correlation to radiological bone loss. CONCLUSION: Within the limitations of this study, titanium implants provided with laser-microtextured surface abutments seem to demonstrate less pro-inflammatory and more anti-inflammatory activity and to show reduced radiographic bone loss compared to machined titanium abutments. CLINICAL RELEVANCE: The use of laser-microtextured surface abutments might have the potential to support peri-implant tissue health.
OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants. MATERIAL AND METHODS: A total of 40 patients with one titanium implant, half of them (n=20) provided with a M abutment (control group) and the other half (n=20) with LMS abutments (test group), were included in the study. Clinical parameters pocket probing depth (PD), full-mouth plaque score (FMPS), radiographic bone loss (RBL), clinical attachment level (CAL), mucosal recession (MR), bleeding on probing (BOP), and width of keratinized mucosa (KM) were evaluated. The peri-implant sulcus fluid was analyzed for cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10 via flow cytometry. RESULTS: Clinical evaluation demonstrated no significant difference of PD (mean LMS = 3.50 mm/SD 0.95 mm vs mean M = 3.45 mm/SD 0.76 mm (p=0.855)), MR (mean LMS = 0.30 mm/SD 0.57 mm vs mean M = 0.35 mm/SD 0.67 mm (p=0.801)), CAL (mean LMS = 3.60 mm/SD 1.14 mm vs mean M = 3.55 mm/SD 0.89 mm (p=0.878)), and KM (mean LMS = 2.03 mm/SD 1.08 mm vs mean M = 2.13 mm/SD 0.92 mm (p=0.754)) between LMS and M abutments. LMS abutments showed less BOP than M abutments (26.7% vs 30.8%), but statistically not significant (p = 0.2235). Radiographic bone loss (mean LMS = 0.22 mm/SD 0.44 mm vs mean M = 0.59 mm/SD 0.49 mm) was reduced in the test group in comparison with the control group (p=0.016). In the collected PICF, the levels of pro-inflammatory cytokines IL-1α (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p=0.968)) and IL-1β (median LMS = 60.43 pg/ml vs M = 83.11 pg/ml (p=0.4777)) were lower, and the levels of IL-6 (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p<0.0001)) were significantly lower in the test group. In contrast, the levels of IL-8 (median LMS = 255.7 pg/ml vs M = 178.7 pg/ml (p=0.3306)) were higher in the test group, though not significantly. The levels of anti-inflammatory IL-10 were significantly increased in the test group (LMS median = 0.555 pg/ml vs M median = 0.465 pg/ml (p=0.0365)). IL-1β showed a significant correlation to radiologic bone loss (p=0.0024). The other variables IL-1α, IL-6, IL-8, and IL-10 had no significant correlation to radiological bone loss. CONCLUSION: Within the limitations of this study, titanium implants provided with laser-microtextured surface abutments seem to demonstrate less pro-inflammatory and more anti-inflammatory activity and to show reduced radiographic bone loss compared to machined titanium abutments. CLINICAL RELEVANCE: The use of laser-microtextured surface abutments might have the potential to support peri-implant tissue health.
Authors: Daniel Buser; Simone F M Janner; Julia-Gabriela Wittneben; Urs Brägger; Christoph A Ramseier; Giovanni E Salvi Journal: Clin Implant Dent Relat Res Date: 2012-12 Impact factor: 3.932
Authors: Frank Schwarz; Ilja Mihatovic; Vladimir Golubovich; Alex Schär; Martin Sager; Jürgen Becker Journal: Clin Oral Implants Res Date: 2014-08-30 Impact factor: 5.977
Authors: Fabio José Persegani Olivar Fonseca; Mario Moraes Junior; Eduardo José Veras Lourenço; Daniel de Moraes Teles; Carlos Marcelo Figueredo Journal: Clin Oral Implants Res Date: 2012-10-29 Impact factor: 5.977
Authors: M Gómez-Florit; J M Ramis; R Xing; S Taxt-Lamolle; H J Haugen; S P Lyngstadaas; M Monjo Journal: J Periodontal Res Date: 2013-08-06 Impact factor: 4.419
Authors: Mariana Brito da Cruz; Joana Faria Marques; Neusa Silva; Sara Madeira; Óscar Carvalho; Filipe Samuel Silva; João Caramês; António Mata Journal: Materials (Basel) Date: 2022-03-28 Impact factor: 3.623