Literature DB >> 19205836

An automated ROI setting method using NEUROSTAT on cerebral blood flow SPECT images.

Toshiyuki Ogura1, Kazuhiro Hida, Toshihide Masuzuka, Hisatoshi Saito, Satoshi Minoshima, Kazuhiro Nishikawa.   

Abstract

OBJECTIVE: We have developed a method to automatically set regions of interest (ROI) (automated ROI) on cerebral blood flow single-photon emission computed tomography (SPECT) images with morphological information specific to the subjects. The objective was to set ROIs automatically without losing individual morphological information in the SPECT images and then evaluate its validity and clinical applicability.
METHODS: We constructed the volume of interest (VOI) template on the standardized brain generated by NEUROSTAT to determine the regions for ROIs to be set. Assuming patients with cerebral vascular disease, the VOI template was constructed so that the ROIs were drawn for the major vascular regions and 17 regions in total within the hemisphere, basal ganglia, thalamus, cerebellar cortex, cerebellar vermis, and pons. By comparing the major vascular occlusion models, the accuracy of region setting by the VOI template was evaluated for validation. Using the anatomical standardization of NEUROSTAT and inverse transformation, the automated ROI transformed the VOI template into the individual brain shape and then the VOI template was extracted from each slice to determine ROIs. An evaluation was made by visually investigating the effect of a different image quality and cerebral blood flow tracers using brain phantom and clinical data. The regional cerebral blood flow (rCBF), determined by the manual setting method of ROI (manual ROI) and automated ROI, was compared. We also compared automated ROI with other morphological images using clinical data.
RESULTS: The VOI templates accurately showed the region with the reduced blood flow in the major vascular occlusion model, which validated the proper ROI setting. The brain phantom study demonstrated that ROI settings were least influenced by matrix size, image quality, and image rotation. The observation with the clinical data also indicated that the variation in cerebral blood flow tracers little affected the ROI settings. The comparison with manual ROI revealed a strong correlation between the two ROI settings, and the mean values within both ROIs were similar. The comparative evaluation with morphological images, obtained by magnetic resonance imaging (MRI), verified the accurate setting of ROI.
CONCLUSIONS: The automated ROI achieved successful automatic ROI settings without distorting individual SPECT images. The automated ROI is not affected by the differences in the image quality or the cerebral blood flow tracers, which suggests versatile applicability. Thus, the use of automated ROI may eliminate the interoperator and interfacility variability in ROI setting and improve objectivity and reproducibility. It also allows comparative evaluation at the same transverse level with images acquired with other modalities such as MRI and is expected to enhance the clinical diagnosis.

Entities:  

Mesh:

Year:  2009        PMID: 19205836     DOI: 10.1007/s12149-008-0203-7

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  9 in total

1.  Cerebral hemodynamic benefits after contralateral carotid artery stenting in patients with internal carotid artery occlusion.

Authors:  F Oka; H Ishihara; S Kato; M Higashi; M Suzuki
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-23       Impact factor: 3.825

2.  Decrease in leptomeningeal ivy sign on fluid-attenuated inversion recovery images after cerebral revascularization in patients with Moyamoya disease.

Authors:  M Kawashima; T Noguchi; Y Takase; Y Nakahara; T Matsushima
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-13       Impact factor: 3.825

3.  Detection of symptomatic vasospasm after subarachnoid haemorrhage: initial findings from single time-point and serial measurements with arterial spin labelling.

Authors:  Kunihiro Aoyama; Yasutaka Fushimi; Tomohisa Okada; Akihiro Miyasaki; Hideaki Taki; Kazunori Shibamoto; Kaori Togashi
Journal:  Eur Radiol       Date:  2012-06-01       Impact factor: 5.315

4.  Absence of the Anterior Communicating Artery on Selective MRA is Associated with New Ischemic Lesions on MRI after Carotid Revascularization.

Authors:  S Yamashita; M Kohta; K Hosoda; J Tanaka; K Matsuo; H Kimura; K Tanaka; A Fujita; T Sasayama
Journal:  AJNR Am J Neuroradiol       Date:  2022-07-14       Impact factor: 4.966

5.  Larger Posterior Revascularization Associated with Reduction of Choroidal Anastomosis in Moyamoya Disease: A Quantitative Angiographic Analysis.

Authors:  T Funaki; A Miyakoshi; H Kataoka; J C Takahashi; Y Takagi; K Yoshida; T Kikuchi; Y Mineharu; M Okawa; Y Yamao; Y Fushimi; S Miyamoto
Journal:  AJNR Am J Neuroradiol       Date:  2022-08-25       Impact factor: 4.966

6.  Quantitative cerebral perfusion assessment using microscope-integrated analysis of intraoperative indocyanine green fluorescence angiography versus positron emission tomography in superficial temporal artery to middle cerebral artery anastomosis.

Authors:  Shinya Kobayashi; Tatsuya Ishikawa; Jun Tanabe; Junta Moroi; Akifumi Suzuki
Journal:  Surg Neurol Int       Date:  2014-09-15

7.  Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom.

Authors:  Mana Akamatsu; Yasuo Yamashita; Go Akamatsu; Yuji Tsutsui; Nobuyoshi Ohya; Yasuhiko Nakamura; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2014

8.  MEG Frequency Analysis Depicts the Impaired Neurophysiological Condition of Ischemic Brain.

Authors:  Shinichi Sakamoto; Hidetoshi Ikeda; Naohiro Tsuyuguchi; Takehiro Uda; Eiichi Okumura; Takashi Asakawa; Yasuhiro Haruta; Hideki Nishiyama; Toyoji Okada; Hajime Kamada; Kenji Ohata; Yukio Miki
Journal:  PLoS One       Date:  2016-12-16       Impact factor: 3.240

9.  Quantitative assessment of rest and acetazolamide CBF using quantitative SPECT reconstruction and sequential administration of (123)I-iodoamphetamine: comparison among data acquired at three institutions.

Authors:  Miho Yamauchi; Etsuko Imabayashi; Hiroshi Matsuda; Jyoji Nakagawara; Masaaki Takahashi; Eku Shimosegawa; Jun Hatazawa; Michiyasu Suzuki; Hideyuki Iwanaga; Kenji Fukuda; Koji Iihara; Hidehiro Iida
Journal:  Ann Nucl Med       Date:  2014-07-08       Impact factor: 2.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.