Literature DB >> 19201324

Group A T-loop for differential moment mechanics: an implant study.

Renato Parsekian Martins1, Peter H Buschang, Luiz Gonzaga Gandini.   

Abstract

INTRODUCTION: When anchorage control is critical and compliance is less than ideal, efficient treatment depends on differential tooth movements. The purpose of this study was to evaluate the distal tipping of partially retracted canines and the mesial movement of the molars.
METHODS: Eleven patients had their maxillary and mandibular canines partially retracted with TMA (Ormco Corp, Orange, Calif) T-loop springs with 45 degrees gable bends distal to the loops preactivated for group A (maximum anchorage). Metallic bone markers served as references. The canines were retracted until enough space was available for alignment of the incisors without proclination. Oblique (45 degrees) radiographs were taken immediately before the initial activation and after partial retraction. The radiographs were scanned, superimposed on the bone markers, and measured digitally.
RESULTS: The mandibular canine crowns were retracted (4.1 +/-1.9 mm) and intruded (0.7 +/- 0.3 mm) by uncontrolled tipping. In contrast, the maxillary canine crowns were retracted (3.2 +/- 1.4 mm) by controlled tipping. The maxillary and mandibular molars crowns were protracted by similar amounts (1.0 +/- 0.6 and 1.2 +/-1.2 mm, respectively) by controlled tipping, without significant extrusion. The molars were protracted approximately 0.3 mm for every 1 mm of canine retraction.
CONCLUSIONS: The T-loop spring used in this investigation produced controlled tipping of the maxillary canines, but it did not produce controlled tipping of the mandibular canines or translation of the molar as expected.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19201324     DOI: 10.1016/j.ajodo.2007.02.055

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  10 in total

1.  Deformation of nickel-titanium closed coil springs: an in vitro study.

Authors:  Camilla Ivini Viana Vieira; José Maurício Dos Santos Nunes Reis; Luiz Geraldo Vaz; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2017-02

2.  Superelasticity and force plateau of nickel-titanium springs: an in vitro study.

Authors:  Camila Ivini Viana Vieira; Sergei Godeiro Fernandes Rabelo Caldas; Lídia Parsekian Martins; Renato Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2016-06

3.  Load system of segmental T-loops for canine retraction.

Authors:  Zeyang Xia; Jie Chen; Feifei Jiangc; Shuning Li; Rodrigo F Viecilli; Sean Y Liu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-10       Impact factor: 2.650

4.  Absolute anchorage with universal T-loop mechanics for severe deepbite and maxillary anterior protrusion and its 10-year stability.

Authors:  Yoon Jeong Choi; Chooryung Judi Chung; Kwangchul Choy; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

5.  The T-loop in details.

Authors:  Amanda Frizzo Viecilli; Maria Perpétua Mota Freitas
Journal:  Dental Press J Orthod       Date:  2018-01

6.  Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs.

Authors:  Hwan-Hyung Park; Suk-Hwan Jung; Juil Yoon; Kwang Koo Jee; Jun Hyun Han; Seung-Hak Baek
Journal:  Korean J Orthod       Date:  2019-07-22       Impact factor: 1.372

7.  Tooth Movement Efficacy of Retraction Spring Made of a New Low Elastic Modulus Material, Gum Metal, Evaluated by the Finite Element Method.

Authors:  Naohiko Tamaya; Jun Kawamura; Yoshinobu Yanagi
Journal:  Materials (Basel)       Date:  2021-05-29       Impact factor: 3.623

8.  Segmented arch or continuous arch technique? A rational approach.

Authors:  Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Hallissa Simplício; André Wilson Machado
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr

Review 9.  Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis.

Authors:  Kathrin Becker; Annika Pliska; Caroline Busch; Benedict Wilmes; Michael Wolf; Dieter Drescher
Journal:  Int J Implant Dent       Date:  2018-10-25

10.  Combined use of miniscrews and continuous arch for intrusive root movement of incisors in Class II division 2 with gummy smile.

Authors:  Sung-Jin Kim; Jin-Wook Kim; Tae-Hyun Choi; Kee-Joon Lee
Journal:  Angle Orthod       Date:  2014-02-07       Impact factor: 2.079

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.