Literature DB >> 19186347

Comparison of 5 flow cytometric immunophenotyping systems for absolute CD4+ T-lymphocyte counts in HIV-1-infected patients living in resource-limited settings.

Kovit Pattanapanyasat1, Yuwadee Phuang-Ngern, Kasama Sukapirom, Surada Lerdwana, Charin Thepthai, Boonrat Tassaneetrithep.   

Abstract

Enumeration of CD4+ T lymphocytes is important in management of HIV-infected patients. However, CD4 testing by current gold standard bead-based flow cytometer (FCM) system is expensive for developing countries. This study compared 2 affordable volumetric FCMs with the 3 predicate FCM systems. CD4+ T-lymphocyte counts on blood samples from 150 HIV-1-infected Thai patients were determined in parallel by 5 FCM systems: the 2 single-platform volumetric FCM systems, Guava and CyFlow(green); the 2 standard single-platform bead-based systems (2-color FACSCount and the TriTEST/TruCOUNT tube using a FACSCalibur FCM); and the dual-platform TriTEST system. Correlation and agreement were analyzed using linear regression and Bland-Altman analysis. Results from these 2 volumetric systems gave similar results and excellent correlation: R2 > 0.93; mean biases ranged from +6.3 to +24.1 cells per microliter more for the Guava. In contrast, the CyFlow(green) showed the lowest values with R2 > 0.97; mean biases ranged from -9.8 to -27.6 cells per microliter. This indicates that the absolute CD4+ T-lymphocyte counts determined by CyFlow(green) are < FACSCount < DP TriTEST < TriTEST/TruCOUNT < Guava. Although the use of these 2 volumetric FCMs could make CD4+ T-lymphocyte enumeration more affordable in resource-poor settings, variations among these systems should be considered if these are to be interchanged.

Entities:  

Mesh:

Year:  2008        PMID: 19186347     DOI: 10.1097/qai.0b013e31818c1721

Source DB:  PubMed          Journal:  J Acquir Immune Defic Syndr        ISSN: 1525-4135            Impact factor:   3.731


  11 in total

1.  Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients' samples.

Authors:  François-Xavier Mbopi-Kéou; Stefano Mion; Bertrand Sagnia; Laurent Bélec
Journal:  Clin Vaccine Immunol       Date:  2012-02-15

2.  Utility of the point of care CD4 analyzer, PIMA, to enumerate CD4 counts in the field settings in India.

Authors:  Madhuri Thakar; Bharati Mahajan; Nawaj Shaikh; Salman Bagwan; Suvarna Sane; Sandhya Kabra; Bharat Rewari; Mohamad Shaukat; Namita Singh; Peter Trevor; Ramesh Paranjape
Journal:  AIDS Res Ther       Date:  2012-09-21       Impact factor: 2.250

3.  Prioritizing CD4 count monitoring in response to ART in resource-constrained settings: a retrospective application of prediction-based classification.

Authors:  Livio Azzoni; Andrea S Foulkes; Yan Liu; Xiaohong Li; Margaret Johnson; Collette Smith; Adeeba Bte Kamarulzaman; Julio Montaner; Karam Mounzer; Michael Saag; Pedro Cahn; Carina Cesar; Alejandro Krolewiecki; Ian Sanne; Luis J Montaner
Journal:  PLoS Med       Date:  2012-04-17       Impact factor: 11.069

Review 4.  Low-cost assays for monitoring HIV infected individuals in resource-limited settings.

Authors:  Pachamuthu Balakrishnan; Hussain Syed Iqbal; Saravanan Shanmugham; Janardhanan Mohanakrishnan; Sunil S Solomon; Kenneth H Mayer; Suniti Solomon
Journal:  Indian J Med Res       Date:  2011-12       Impact factor: 2.375

5.  Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Abdoul Aziz Diallo; Souleymane Mboup; Tandakha Ndiaye Dieye; Luc Kestens
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

6.  WHO multicenter evaluation of FACSCount CD4 and Pima CD4 T-cell count systems: instrument performance and misclassification of HIV-infected patients.

Authors:  Djibril Wade; Géraldine Daneau; Said Aboud; Gaby H Vercauteren; Willy S K Urassa; Luc Kestens
Journal:  J Acquir Immune Defic Syndr       Date:  2014-08-15       Impact factor: 3.731

Review 7.  CD4 enumeration technologies: a systematic review of test performance for determining eligibility for antiretroviral therapy.

Authors:  Rosanna W Peeling; Kimberly A Sollis; Sarah Glover; Suzanne M Crowe; Alan L Landay; Ben Cheng; David Barnett; Thomas N Denny; Thomas J Spira; Wendy S Stevens; Siobhan Crowley; Shaffiq Essajee; Marco Vitoria; Nathan Ford
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

8.  Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Ngamasra Nadjiouroum; Barou Djouater; Noël Djemadji-Oudjeil; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Res Notes       Date:  2013-04-30

9.  CD4 T-cell enumeration in a field setting: evaluation of CyFlow counter using the CD4 easy count kit-dry and Pima CD4 systems.

Authors:  Djibril Wade; Papa Alassane Diaw; Géraldine Daneau; Makhtar Camara; Tandakha Ndiaye Dieye; Souleymane Mboup; Luc Kestens
Journal:  PLoS One       Date:  2013-09-16       Impact factor: 3.240

10.  Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Barou Djouater; Noël Djemadji-Oudjeil; Francois-Xavier Mbopi-Keou; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Health Serv Res       Date:  2013-10-01       Impact factor: 2.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.