Literature DB >> 19183601

Technique for the focal-length measurement of positive lenses using Fizeau interferometry.

Yeddanapudi Pavan Kumar1, Sanjib Chatterjee.   

Abstract

We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of +/-2.5% is presented.

Year:  2009        PMID: 19183601     DOI: 10.1364/ao.48.000730

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  1 in total

1.  Research on Focal Length Measurement Scheme of Self-Collimating Optical Instrument Based on Double Grating.

Authors:  Wenchang Yang; Zhiqian Wang; Chengwu Shen; Yusheng Liu; Shaojin Liu; Qinwen Li; Wen Du; Zhuoda Song
Journal:  Sensors (Basel)       Date:  2020-05-10       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.