Literature DB >> 19181979

Revision of the acetabular component without cement. A concise follow-up, at twenty to twenty-four years, of a previous report.

Daniel K Park1, Craig J Della Valle, Laura Quigley, Mario Moric, Aaron G Rosenberg, Jorge O Galante.   

Abstract

We previously reported the results of the use of a cementless acetabular shell for revision total hip arthroplasty in 138 hips at a minimum of three, seven, and fifteen years postoperatively. The current report presents the long-term outcomes of this group at a minimum follow-up of twenty years. Since the last report, two additional hips required repeat revision, both for infection; no additional acetabular shell was loose. In the entire series to date, repeat acetabular revision was performed in twenty-one (15%) of the original 138 hips. Twenty of the twenty-one shells were well fixed at the time of repeat revision, and one had become aseptically loose. The most common reasons for repeat revision were infection (eight hips) and recurrent instability (eight hips). In the metal shells that were well fixed, an isolated liner change for polyethylene wear and/or osteolysis was performed in a total of six hips; four of these liner exchanges were performed since the time of our last report. A liner change had been recommended because of severe wear in four additional hips; thus, 18% of the fifty-six unrevised metal shells were associated with polyethylene wear-related problems. Survivorship, with revision of the shell for aseptic loosening or radiographic evidence of loosening as the end point, was 95% at twenty years (95% confidence interval, 83% to 98%). Reoperations for wear and osteolysis were first seen at approximately twelve years postoperatively. At the time of the present long-term follow-up, the reoperation rate for polyethylene wear and/or osteolysis had increased. We continue to use a hemispherical, titanium metal shell with multiple screws for fixation in the majority of acetabular revisions.

Entities:  

Mesh:

Year:  2009        PMID: 19181979     DOI: 10.2106/JBJS.H.00302

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  14 in total

1.  Large acetabular defects can be managed with cementless revision components.

Authors:  E Scott Paxton; James A Keeney; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

Review 2.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

3.  Optimisation of the enamelling of an apatite-mullite glass-ceramic coating on Ti6Al4V.

Authors:  Kevin P O'Flynn; Kenneth T Stanton
Journal:  J Mater Sci Mater Med       Date:  2011-07-20       Impact factor: 3.896

Review 4.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

5.  Reconstruction options for acetabular revision.

Authors:  Erica D Taylor; James A Browne
Journal:  World J Orthop       Date:  2012-07-18

6.  Method of fixation does not influence the overall risk of rerevision in first-time cup revisions.

Authors:  Maziar Mohaddes; Göran Garellick; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

7.  Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

Authors:  Colin T Penrose; Thorsten M Seyler; Samuel S Wellman; Michael P Bolognesi; Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

8.  Regeneration of the articular surface of the rabbit synovial joint by cell homing: a proof of concept study.

Authors:  Chang H Lee; James L Cook; Avital Mendelson; Eduardo K Moioli; Hai Yao; Jeremy J Mao
Journal:  Lancet       Date:  2010-08-07       Impact factor: 79.321

9.  Total Hip Arthroplasty Performed for Coxarthrosis Preserves Long-Term Physical Function: A 40-Year Experience.

Authors:  Philip D Wilson; Leslee Wong; Yuo-Yu Lee; Stephen Lyman; Charles N Cornell
Journal:  HSS J       Date:  2019-04-22

Review 10.  Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

Authors:  Heinz Winkler
Journal:  Int J Med Sci       Date:  2009-09-04       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.