Literature DB >> 19175111

Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy.

R M Thomson1, R E P Taylor, D W O Rogers.   

Abstract

A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model 125I (model 6711) and 103Pd (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS). Three-dimensional dose distributions in the eye region are obtained. In general, dose to water is scored; however, the implications of replacing water with eye tissues are explored. The effect of the gold alloy (Modulay) backing is investigated and the dose is found to be sensitive to the elemental composition of the backing. The presence of the silicone polymer (Silastic) seed carrier results in substantial dose decreases relative to water, particularly for 103Pd. For a 20 mm plaque with a Modulay backing and Silastic insert, fully loaded with 24 seeds, the dose decrease relative to water is of the order of 14% for 125I and 20% for 103Pd at a distance of 1 cm from the inner sclera along the plaque's central axis. For the configurations of seeds used in COMS plaques, interseed attenuation is a small effect within the eye region. The introduction of an air interface results in a dose reduction in its vicinity which depends on the plaque's position within the eye and the radionuclide. Introducing bone in the eye's vicinity also causes dose reductions. The dose distributions in the eye for the two different radionuclides are compared and, for the same prescription dose, 103Pd generally offers a lower dose to critical normal structures. BrachyDose is sufficiently fast to allow full Monte Carlo dose calculations for routine clinical treatment planning.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19175111     DOI: 10.1118/1.3002412

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Visual acuity, oncologic, and toxicity outcomes with 103Pd vs. 125I plaque treatment for choroidal melanoma.

Authors:  Kirtesh R Patel; Roshan S Prabhu; Jeffrey M Switchenko; Mudit Chowdhary; Caroline Craven; Pia Mendoza; Hasan Danish; Hans E Grossniklaus; Thomas M Aaberg; Thomas Aaberg; Sahitya Reddy; Elizabeth Butker; Chris Bergstrom; Ian R Crocker
Journal:  Brachytherapy       Date:  2017-03-03       Impact factor: 2.362

2.  Comparison of dose calculation methods for brachytherapy of intraocular tumors.

Authors:  Mark J Rivard; Sou-Tung Chiu-Tsao; Paul T Finger; Ali S Meigooni; Christopher S Melhus; Firas Mourtada; Mary E Napolitano; D W O Rogers; Rowan M Thomson; Ravinder Nath
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  The effects of intraocular silicone oil placement prior to iodine 125 brachytherapy for uveal melanoma: a clinical case series.

Authors:  Y Ahuja; K G Kapoor; R M Thomson; K M Furutani; R W Shultz; S L Stafford; S Dev; N E Abu-Yaghi; D Reynolds; J S Pulido
Journal:  Eye (Lond)       Date:  2012-08-31       Impact factor: 3.775

4.  Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy.

Authors:  Payvand Taherparvar; Zeinab Fardi
Journal:  Nucl Med Mol Imaging       Date:  2021-01-11

Review 5.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

Review 6.  A brief look at model-based dose calculation principles, practicalities, and promise.

Authors:  Ron S Sloboda; Hali Morrison; Brie Cawston-Grant; Geetha V Menon
Journal:  J Contemp Brachytherapy       Date:  2017-02-08

7.  Gamma irradiation of ocular melanoma and lymphoma cells in the presence of gold nanoparticles: in vitro study.

Authors:  Mozhgan Rezaei Kanavi; Somayeh Asadi; Sahar Balagholi; Fatemeh Alikarami; Hassan Nosrati; Hamid Ahmadieh
Journal:  J Appl Clin Med Phys       Date:  2018-04-29       Impact factor: 2.102

8.  Gold nanoparticle-based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye.

Authors:  Somayeh Asadi; Mehdi Vaez-zadeh; S Farhad Masoudi; Faezeh Rahmani; Courtney Knaup; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

9.  Keeping an eye on the ring: COMS plaque loading optimization for improved dose conformity and homogeneity.

Authors:  Nolan L Gagne; Daniel R Cutright; Mark J Rivard
Journal:  J Contemp Brachytherapy       Date:  2012-09-29

10.  Comparison of 16 mm OSU-Nag and COMS eye plaques.

Authors:  Hualin Zhang; Frederick Davidorf; Yujin Qi
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.