Literature DB >> 19171516

Directly manipulated free-form deformation image registration.

Nicholas J Tustison1, Brian B Avants, James C Gee.   

Abstract

Previous contributions to both the research and open source software communities detailed a generalization of a fast scalar field fitting technique for cubic B-splines based on the work originally proposed by Lee . One advantage of our proposed generalized B-spline fitting approach is its immediate application to a class of nonrigid registration techniques frequently employed in medical image analysis. Specifically, these registration techniques fall under the rubric of free-form deformation (FFD) approaches in which the object to be registered is embedded within a B-spline object. The deformation of the B-spline object describes the transformation of the image registration solution. Representative of this class of techniques, and often cited within the relevant community, is the formulation of Rueckert who employed cubic splines with normalized mutual information to study breast deformation. Similar techniques from various groups provided incremental novelty in the form of disparate explicit regularization terms, as well as the employment of various image metrics and tailored optimization methods. For several algorithms, the underlying gradient-based optimization retained the essential characteristics of Rueckert's original contribution. The contribution which we provide in this paper is two-fold: 1) the observation that the generic FFD framework is intrinsically susceptible to problematic energy topographies and 2) that the standard gradient used in FFD image registration can be modified to a well-understood preconditioned form which substantially improves performance. This is demonstrated with theoretical discussion and comparative evaluation experimentation.

Entities:  

Mesh:

Year:  2009        PMID: 19171516     DOI: 10.1109/TIP.2008.2010072

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  17 in total

Review 1.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

2.  Pulmonary kinematics from tagged hyperpolarized helium-3 MRI.

Authors:  Nicholas J Tustison; Suyash P Awate; Jing Cai; Talissa A Altes; G Wilson Miller; Eduard E de Lange; John P Mugler; James C Gee
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

3.  Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

Authors:  Alison M Pouch; Hongzhi Wang; Manabu Takabe; Benjamin M Jackson; Chandra M Sehgal; Joseph H Gorman; Robert C Gorman; Paul A Yushkevich
Journal:  Med Image Comput Comput Assist Interv       Date:  2013

4.  Internal three-dimensional strains in human intervertebral discs under axial compression quantified noninvasively by magnetic resonance imaging and image registration.

Authors:  Jonathon H Yoder; John M Peloquin; Gang Song; Nick J Tustison; Sung M Moon; Alexander C Wright; Edward J Vresilovic; James C Gee; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2014-11       Impact factor: 2.097

5.  A Learning Based Fiducial-driven Registration Scheme for Evaluating Laser Ablation Changes in Neurological Disorders.

Authors:  Tao Wan; B Nicolas Bloch; Shabbar Danish; Anant Madabhushi
Journal:  Neurocomputing       Date:  2014-11-20       Impact factor: 5.719

6.  Image texture features predict renal function decline in patients with autosomal dominant polycystic kidney disease.

Authors:  Timothy L Kline; Panagiotis Korfiatis; Marie E Edwards; Kyongtae T Bae; Alan Yu; Arlene B Chapman; Michal Mrug; Jared J Grantham; Douglas Landsittel; William M Bennett; Bernard F King; Peter C Harris; Vicente E Torres; Bradley J Erickson
Journal:  Kidney Int       Date:  2017-05-20       Impact factor: 10.612

7.  Human Disc Nucleotomy Alters Annulus Fibrosus Mechanics at Both Reference and Compressed Loads.

Authors:  Amy A Claeson; Edward J Vresilovic; Brent L Showalter; Alexander C Wright; James C Gee; Neil R Malhotra; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2019-05-29       Impact factor: 2.097

8.  Progressive adaptation in regional parenchyma mechanics following extensive lung resection assessed by functional computed tomography.

Authors:  Cuneyt Yilmaz; Nicholas J Tustison; D Merrill Dane; Priya Ravikumar; Masaya Takahashi; James C Gee; Connie C W Hsia
Journal:  J Appl Physiol (1985)       Date:  2011-07-28

9.  A reproducible evaluation of ANTs similarity metric performance in brain image registration.

Authors:  Brian B Avants; Nicholas J Tustison; Gang Song; Philip A Cook; Arno Klein; James C Gee
Journal:  Neuroimage       Date:  2010-09-17       Impact factor: 6.556

10.  Semiautomated Segmentation of Polycystic Kidneys in T2-Weighted MR Images.

Authors:  Timothy L Kline; Marie E Edwards; Panagiotis Korfiatis; Zeynettin Akkus; Vicente E Torres; Bradley J Erickson
Journal:  AJR Am J Roentgenol       Date:  2016-06-24       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.