Literature DB >> 19168907

Comparing ultrasound biometry with partial coherence interferometry for intraocular lens power calculations: a randomized study.

Simon Raymond1, Ian Favilla, Linda Santamaria.   

Abstract

PURPOSE: To determine whether intraocular lens (IOL) power calculations for cataract surgery as measured by postoperative refractive error using partial coherence interferometry (PCI) are more accurate in improving postoperative outcomes than applanation ultrasound biometry (AUS).
METHODS: A double-blind randomized controlled trial consisting of 205 patients was undertaken by the Southern Health Ophthalmology Unit, Victoria, Australia. Mean absolute postoperative refractive error (MAE) represented the dependent variable; the biometric technique (PCI; AUS) used to determine the IOL power to be implanted in the surgical eye represented the independent variable. An intention-to-treat analysis was used to prevent loss of randomization caused by the effects of crossover and drop-out.
RESULTS: The MAE in patients with implanted PCI-calculated IOLs was 0.40 +/- 0.37 D (SD; 95% confidence interval [CI], 0.32-0.48 D) compared with 0.45 +/- 0.41 D (SD; 95% CI, 0.36-0.54 D) for patients with implanted AUS-calculated IOLs. There was no statistically significant difference between MAE in patients with implanted PCI-calculated IOLs and that in patients with AUS-calculated IOLs in analysis of best possible outcomes (t(167) = 1.0, P = 0.315).
CONCLUSIONS: The results of this trial demonstrated that the calculation of IOL power based on ocular axial length measurement with PCI technology provided no clinical advantage over conventional applanation ultrasound, as measured by postoperative refractive outcome (anzctr.org.au number, ACTRN12608000077369).

Entities:  

Mesh:

Year:  2009        PMID: 19168907     DOI: 10.1167/iovs.08-3087

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  8 in total

1.  Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation.

Authors:  Mirjana Bjeloš Rončević; Mladen Bušić; Ivan Cima; Biljana Kuzmanović Elabjer; Damir Bosnar; Daliborka Miletić
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-18       Impact factor: 3.117

2.  Comparison of intraocular lens power prediction using immersion ultrasound and optical biometry with and without formula optimization.

Authors:  Gabor Nemeth; Attila Nagy; Andras Berta; Laszlo Modis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-13       Impact factor: 3.117

3.  Comparative Analysis of Swept-Source Optical Coherence Tomography and Partial Coherence Interferometry Biometers in the Prediction of Cataract Surgery Refractive Outcomes.

Authors:  Arthur B Cummings; Stephanie Naughton; Ann-Marie Coen; Elizabeth Brennan; Gabrielle E Kelly
Journal:  Clin Ophthalmol       Date:  2020-12-02

4.  Accuracy of Holladay 2 formula using IOLMaster parameters in the absence of lens thickness value.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan; Niphon Chirapapaisan; Buntitar Lertsuwanroj; Mathinee Chongchareon
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-15       Impact factor: 3.117

5.  Relationships between central and peripheral corneal thickness in different degrees of myopia.

Authors:  Sara Ortiz; Laura Mena; Ana Rio-San Cristobal; Raul Martin
Journal:  J Optom       Date:  2013-05-16

6.  The impact of unilateral or bilateral cataract surgery on visual acuity and life quality of elderly patients.

Authors:  Lei Zuo; Haidong Zou; Xinfeng Fei; Weiqi Xu; Jianhong Zhang
Journal:  J Ophthalmol       Date:  2015-03-22       Impact factor: 1.909

7.  Personal A-constant in relation to axial length with various intraocular lenses.

Authors:  Mohamed A Eldaly; Khaled A Mansour
Journal:  Indian J Ophthalmol       Date:  2014-07       Impact factor: 1.848

8.  Biometry characteristics in congenital cataract patients before surgery in a tertiary eye care centre in Nepal.

Authors:  Sabin Sahu; Paras Panjiyar
Journal:  Saudi J Ophthalmol       Date:  2019-07-17
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.