Precision of shoulder anatomical landmark calibration by two approaches: a CAST-like protocol and a new anatomical palpator method.

P Salvia1, S Van Sint Jan, A Crouan, L Vanderkerken, F Moiseev, V Sholukha, C Mahieu, O Snoeck, M Rooze.   

Abstract

The objective of the study was to compare the precision of shoulder anatomical landmark palpation using a CAST-like method and a newly developed anatomical palpator device (called A-Palp) using the forefinger pulp directly. The repeated-measures experimental design included four examiners that twice repeated measurements on eleven scapula and humerus anatomical landmarks during two sessions. Inter-session and inter-examiner precision was determined on volunteers. A-Palp accuracy was obtained from in vitro measurements and using virtual palpation on 3D bone models. Error propagation on the motion representation was also analyzed for a continuous motion of abduction movement performed in the shoulder joint. Palpation results showed that CAST and A-Palp methods lead to similar precision with the Maximal A-Palp calibration error being 1.5mm. In vivo precision of the CAST and A-Palp methods varied between 4mm (inter-session) and 8mm (inter-examiner). Mean propagation of the palpation error on the motion graph representation was 2 degrees and 5 degrees for scapula and humerus, respectively. A-Palp accuracy was 3.6 and 8.1mm for scapula and humerus, respectively. The A-Palp seems promising and could probably become an additional method next to today's marker-based motion analysis systems (i.e., Helen-Hayes configuration, CAST method).

Entities:  

Mesh:

Year:  2009        PMID: 19168358     DOI: 10.1016/j.gaitpost.2008.12.013

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  5 in total

1.  Shoulder bony landmarks location using the EOS low-dose stereoradiography system: a reproducibility study.

Authors:  Xavier Ohl; Claire Stanchina; Fabien Billuart; Wafa Skalli
Journal:  Surg Radiol Anat       Date:  2009-10-06       Impact factor: 1.246

2.  Shoulder motion during tennis serve: dynamic and radiological evaluation based on motion capture and magnetic resonance imaging.

Authors:  Caecilia Charbonnier; Sylvain Chagué; Frank C Kolo; Alexandre Lädermann
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-14       Impact factor: 2.924

3.  The relationship between various anatomical landmarks used for localizing the first rib during surface palpation.

Authors:  Brian J Loyd; Kerry K Gilbert; Phillip S Sizer; Lee T Atkins; Stéphane Sobczak; Jean-Michel Brismée; Timothy J Pendergrass
Journal:  J Man Manip Ther       Date:  2014-08

4.  EVALUATION OF SCAPULAR DYSKINESIA IN PATIENTS THAT UNDERWENT A LATARJET PROCEDURE.

Authors:  Guilherme do Val Sella; Luciana Andrade da Silva; Gabriel Ximenes Almeida; Dinah Santos Santana; Ana Maria Forti Barela; Alberto Naoki Miyazaki
Journal:  Acta Ortop Bras       Date:  2022-05-23       Impact factor: 0.683

5.  Accuracy and repeatability of smartphone sensors for measuring shank-to-vertical angle.

Authors:  Brandon T Nguyen; Nick A Baicoianu; Darrin B Howell; Keshia M Peters; Katherine M Steele
Journal:  Prosthet Orthot Int       Date:  2020-04-21       Impact factor: 1.895

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.