Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.

Audrey Le1, Mary Ellen Hoehn, Mary E Smith, Thomas Spentzas, David Schlappy, Jay Pershad.   

Abstract

STUDY
OBJECTIVE: We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure.
METHODS: Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestanding pediatric facility. Pediatric emergency physicians with goal-directed training in ophthalmic sonography measured optic nerve sheath diameter. Images were recorded and subsequently reviewed by a pediatric ophthalmologist and an ophthalmic sonographer, both of whom were blind to the patient's clinical condition. Measurements obtained by the ophthalmic sonographer were considered the criterion standard. An optic nerve sheath diameter greater than 4.0 mm in subjects younger than 1 year and greater than 4.5 mm in older children was considered abnormal. The diagnosis of increased intracranial pressure was based on results of cranial imaging or direct measurement of intracranial pressure.
RESULTS: Sixty-four patients were recruited, of whom 24 (37%) had a confirmed diagnosis of increased intracranial pressure. The sensitivity of optic nerve sheath diameter as a screening test for increased intracranial pressure was 83% (95% confidence interval [CI] 0.60 to 0.94); specificity was 38% (95% CI 0.23 to 0.54); positive likelihood ratio was 1.32 (95% CI 0.97 to 1.79) and negative likelihood ratio was 0.46 (95% CI 0.18 to 1.23). There was fair to good interobserver agreement between the pediatric emergency physician and ophthalmic sonographer (kappa 0.52) and pediatric ophthalmologist (kappa 0.64).
CONCLUSION: The sensitivity and specificity of bedside sonographic measurement of optic nerve sheath diameter is inadequate to aid medical decisionmaking in children with suspected increased intracranial pressure. Pediatric emergency physicians with focused training by a pediatric ophthalmologist familiar with ophthalmic sonography can measure optic nerve sheath diameter accurately.

Entities:  

Mesh:

Year:  2009        PMID: 19167786     DOI: 10.1016/j.annemergmed.2008.11.025

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  44 in total

1.  Time for a Comprehensive Ultrasound- Enhanced Trauma Management.

Authors:  Mauro Zago
Journal:  Eur J Trauma Emerg Surg       Date:  2009-08       Impact factor: 3.693

2.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 3.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

4.  Optic nerve sheath diameter as criteria for endoscopic third ventriculostomy failure in children.

Authors:  Llewellyn C Padayachy; A Graham Fieggen
Journal:  Childs Nerv Syst       Date:  2015-06-18       Impact factor: 1.475

Review 5.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

6.  High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

Authors:  Marc Steinborn; Melanie Friedmann; Christine Makowski; Helmut Hahn; Alexander Hapfelmeier; Hendrik Juenger
Journal:  Childs Nerv Syst       Date:  2016-01-13       Impact factor: 1.475

7.  Optic nerve sheath diameter measurements by CT scan in ventriculoperitoneal shunt obstruction.

Authors:  Syed Javed H Zaidi; Loren G Yamamoto
Journal:  Hawaii J Med Public Health       Date:  2014-08

8.  Optic Nerve Measurement on MRI in the Pediatric Population: Normative Values and Correlations.

Authors:  C E Al-Haddad; M G Sebaaly; R N Tutunji; C J Mehanna; S R Saaybi; A M Khamis; R G Hourani
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-07       Impact factor: 3.825

9.  [Non-invasive estimation of intracranial pressure : MR-based evaluation in children with hydrocephalus].

Authors:  M Muehlmann; D Steffinger; A Peraud; M Lehner; F Heinen; N Alperin; B Ertl-Wagner; I K Koerte
Journal:  Radiologe       Date:  2012-09       Impact factor: 0.635

10.  Time-critical neurological emergencies: the unfulfilled role for point-of-care testing.

Authors:  Jason T McMullan; William A Knight; Joseph F Clark; Fred R Beyette; Arthur Pancioli
Journal:  Int J Emerg Med       Date:  2010-05-18
View more