Literature DB >> 19167191

Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry.

J M Plooij1, G R J Swennen, F A Rangel, T J J Maal, F A C Schutyser, E M Bronkhorst, A M Kuijpers-Jagtman, S J Bergé.   

Abstract

In 3D photographs the bony structures are neither available nor palpable, therefore, the bone-related landmarks, such as the soft tissue gonion, need to be redefined. The purpose of this study was to determine the reproducibility and reliability of 49 soft tissue landmarks, including newly defined 3D bone-related soft tissue landmarks with the use of 3D stereophotogrammetric images. Two observers carried out soft-tissue analysis on 3D photographs twice for 20 patients. A reference frame and 49 landmarks were identified on each 3D photograph. Paired Student's t-test was used to test the reproducibility and Pearson's correlation coefficient to determine the reliability of the landmark identification. Intra- and interobserver reproducibility of the landmarks were high. The study showed a high reliability coefficient for intraobserver (0.97 (0.90 - 0.99)) and interobserver reliability (0.94 (0.69 - 0.99)). Identification of the landmarks in the midline was more precise than identification of the paired landmarks. In conclusion, the redefinition of bone-related soft tissue 3D landmarks in combination with the 3D photograph reference system resulted in an accurate and reliable 3D photograph based soft tissue analysis. This shows that hard tissue data are not needed to perform accurate soft tissue analysis.

Entities:  

Mesh:

Year:  2009        PMID: 19167191     DOI: 10.1016/j.ijom.2008.12.009

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  43 in total

1.  3D soft tissue analysis--part 2: vertical parameters.

Authors:  Janka Kochel; Philipp Meyer-Marcotty; Michael Kochel; Susanne Schneck; Angelika Stellzig-Eisenhauer
Journal:  J Orofac Orthop       Date:  2010-05-26       Impact factor: 1.938

2.  Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry.

Authors:  Yongwei Guo; Alexander C Rokohl; Friederike Schaub; Xiaoyi Hou; Jinhua Liu; Yue Ruan; Renbing Jia; Konrad R Koch; Ludwig M Heindl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-08-12       Impact factor: 3.117

3.  The relationship between 3D dentofacial photogrammetry measurements and traditional cephalometric measurements.

Authors:  Jose C Castillo; Grace Gianneschi; Demyana Azer; Amornrut Manosudprasit; Arshan Haghi; Neetu Bansal; Veerasathpurush Allareddy; Mohamed I Masoud
Journal:  Angle Orthod       Date:  2019-03       Impact factor: 2.079

Review 4.  Three-Dimensional Imaging in Orthodontics.

Authors:  Oya Erten; Burcu Nur Yılmaz
Journal:  Turk J Orthod       Date:  2018-04-11

5.  Comparison of actual surgical outcomes and 3-dimensional surgical simulations.

Authors:  Scott Tucker; Lucia Helena Soares Cevidanes; Martin Styner; Hyungmin Kim; Mauricio Reyes; William Proffit; Timothy Turvey
Journal:  J Oral Maxillofac Surg       Date:  2010-06-29       Impact factor: 1.895

6.  Three-dimensional facial analysis in acromegaly: a novel tool to quantify craniofacial characteristics after long-term remission.

Authors:  M A E M Wagenmakers; S H P P Roerink; T J J Maal; R H Pelleboer; J W A Smit; A R M M Hermus; S J Bergé; R T Netea-Maier; T Xi
Journal:  Pituitary       Date:  2015-02       Impact factor: 4.107

7.  Assessment of facial soft-tissue profiles based on lateral photographs versus three-dimensional face scans.

Authors:  Martin Fink; Ursula Hirschfelder; Veronika Hirschinger; Matthias Schmid; Caroline Spitzl; Andreas Detterbeck; Elisabeth Hofmann
Journal:  J Orofac Orthop       Date:  2016-11-03       Impact factor: 1.938

8.  Metric precision via soft-tissue landmarks in three-dimensional structured-light scans of human faces.

Authors:  M Fink; J Medelnik; K Strobel; U Hirschfelder; E Hofmann
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

9.  Three-dimensional evaluation of changes in lip position from before to after orthodontic appliance removal.

Authors:  Lindsey Eidson; Lucia H S Cevidanes; Leonardo Koerich de Paula; H Garland Hershey; Gregory Welch; P Emile Rossouw
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-09       Impact factor: 2.650

10.  Facial soft tissue volume decreases during metreleptin treatment in patients with partial and generalized lipodystrophy.

Authors:  Konstanze Miehle; Michael Stumvoll; Mathias Fasshauer; Thomas Hierl
Journal:  Endocrine       Date:  2017-10-09       Impact factor: 3.633

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.