An analysis of the effect of a vent hole on excess cement expressed at the crown-abutment margin for cement-retained implant crowns.

Dipan Patel1, James C F Invest, Christopher J Tredwin, Derrick J Setchell, David R Moles.   

Abstract

PURPOSE: The labial margins of anterior implant-retained crowns are often positioned subgingivally for a superior esthetic appearance. One of the consequences of subgingival margins is the increased risk of leaving excess cement behind following cementation. This can lead to potential problems, including peri-implant inflammation, soft tissue swelling, soreness, bleeding or suppuration on probing, and bone loss. The purpose of this laboratory study was to investigate the effect of placement, location, and diameter of a vent hole on the amount of cement being expressed at the margin of an anterior implant abutment-retained crown.
MATERIALS AND METHODS: Three implant crown copings were fabricated to fit on the same custom abutment. Three vent diameters (0.75, 1.25, and 1.65 mm) and three locations on the palatal surface of the coping (cervico-palatally, mid-palatally, inciso-palatally) were chosen for vent hole placement. For each test, the coping was cemented onto the abutment under standardized conditions. A preweighed thin coating of cement was applied to the fit surface of the coping. The amount of cement expressed at the margin and vent hole was measured by weight and calculated as a proportion of the amount of cement placed in the coping before seating. The procedure was completed 15 times for each variable. The results were statistically analyzed using univariate ANOVA with post hoc Bonferroni-adjusted independent samples t-tests.
RESULTS: The presence of a vent hole influenced the proportion of cement expressed at the coping margin (p < 0.05). The location of a vent hole influenced the proportion of cement expressed at the coping margin (p < 0.05), with the exception of the mid-palatal and inciso-palatal positioning where there was no significant difference (p= 0.61) between groups. The diameter of the vent hole did not significantly influence the proportion of cement expressed at the coping margin (p= 0.096).
CONCLUSIONS: When using anterior cement-retained implant crowns, the use of a 0.75-mm mid-palatal or inciso-palatal vent hole to minimize the amount of cement expressed at the margin during cementation should be considered.

Entities:  

Mesh:

Year:  2009        PMID: 19166549     DOI: 10.1111/j.1532-849X.2008.00374.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

1.  Extra oral cementation of implant prosthesis: a case report.

Authors:  Rita Singh; Lanka Mahesh; Sagrika Shukla
Journal:  J Indian Prosthodont Soc       Date:  2013-09-27

2.  Should the vent hole of posterior implant crowns be placed on the lateral surface? An in vitro study of the hydrodynamic feature of cement extrusion and retention ability.

Authors:  Sixian Ye; Huangjun Zhou; Xingyu Lyu; Hao Feng; Min Liu; Cai Wen
Journal:  PLoS One       Date:  2022-10-20       Impact factor: 3.752

3.  Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China.

Authors:  Cai Wen; Rong Jiang; Zhiqiang Zhang; Bo Lei; Yingquan Zhong; Huangjun Zhou
Journal:  Patient Prefer Adherence       Date:  2022-02-17       Impact factor: 2.711

4.  Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Authors:  Huangjun Zhou; Sixian Ye; Min Liu; Hao Feng; Cai Wen
Journal:  BMC Oral Health       Date:  2022-04-02       Impact factor: 2.757

5.  A finite element analysis of novel vented dental abutment geometries for cement-retained crown restorations.

Authors:  Lucas C Rodriguez; Juliana N Saba; Clark A Meyer; Kwok-Hung Chung; Chandur Wadhwani; Danieli C Rodrigues
Journal:  Clin Exp Dent Res       Date:  2016-06-14