Literature DB >> 19163576

Adapting population liver motion models for individualized online image-guided therapy.

Thao-Nguyen Nguyen1, Joanne L Moseley, Laura A Dawson, David A Jaffray, Kristy K Brock.   

Abstract

Respiratory motion varies on a daily basis in abdominal cancer patients, affecting the ability to successfully deliver local therapy and requiring increased treatment margins to account for this variation. Deformable registration techniques can accurately describe respiratory motion, however, online application can be limited by long computational times and user intervention. A technique has been developed to quickly quantify patient breathing motion from respiratory-sorted volumetric images by calculating 1D shifts in image intensities between spatially corresponding regions of interest (navigator channels) on patient's images. The 1D motion at the superior, inferior, anterior, and posterior liver edges was detected and applied to adapt a population liver respiratory motion model. For validation, deformable registration was performed for each patient using a validated technique, MORFEUS, for relative validation, and vessel bifurcations, identified on patient's inhale and exhale images, for absolute validation. The accuracy of the adapted-population model to describe the patient respiratory motion was (absolute mean +/- SD) 0.26 +/- 0.11 cm and 0.30 +/- 0.21 cm in the superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The accuracy of predicting the tumor COM motion was 0.30 +/- 0.22 cm, and 0.34 +/- 0.31, while the absolute validation, based on bifurcations was 0.26 +/- 0.16 cm and 0.13 +/- 0.04 cm in the SI and AP directions, respectively. This technique was developed to complement and quickly adapt a full 3D biomechanical based deformable registration technique, MORFEUS, to be applied in the online setting.

Entities:  

Mesh:

Year:  2008        PMID: 19163576     DOI: 10.1109/IEMBS.2008.4650073

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Effectiveness of temporal and dynamic subtraction images of the liver for detection of small HCC on abdominal CT images: comparison of 3D nonlinear image-warping and 3D global-matching techniques.

Authors:  Eiichiro Okumura; Shigeru Sanada; Masayuki Suzuki; Akihiro Takemura; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2011-01-13

2.  Real time 4D IMRT treatment planning based on a dynamic virtual patient model: proof of concept.

Authors:  Bingqi Guo; X George Xu; Chengyu Shi
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

3.  Adapting liver motion models using a navigator channel technique.

Authors:  T N Nguyen; J L Moseley; L A Dawson; D A Jaffray; K K Brock
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

4.  Navigator channel adaptation to reconstruct three dimensional heart volumes from two dimensional radiotherapy planning data.

Authors:  Angela Ng; Thao-Nguyen Nguyen; Joanne L Moseley; David C Hodgson; Michael B Sharpe; Kristy K Brock
Journal:  BMC Med Phys       Date:  2012-01-18

5.  Stereoscopic liver surface reconstruction.

Authors:  Dominik Spinczyk; Adam Karwan; Jerzy Rudnicki; Tadeusz Wróblewski
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2012-06-25       Impact factor: 1.195

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.