Non-invasive measurement of Valsalva-induced hemodynamic changes on a bathroom scale ballistocardiograph.

Omer T Inan1, Mozziyar Etemadi, Richard M Wiard, Gregory T A Kovacs, Laurent Giovangrandi.   

Abstract

Unobtrusive and compact methods for monitoring time varying hemodynamic trends can allow physicians to monitor heart failure of outpatients at home. In this paper, the ballistocardiogram (BCG), measured on a modified commercial bathroom scale, is proposed as a viable option for this important need. The BCG measures the reaction force of the body to cardiac ejection of blood and is a non-invasive tool for evaluating cardiovascular function. The Valsalva maneuver was used to modulate the hemodynamics in a well documented manner, and BCG signals were acquired from 15 subjects. The electrocardiogram (ECG) was simultaneously obtained to measure the electrical to mechanical delay in ventricular contraction: the interval from the ECG R-wave peak to the BCG J-wave peak. This interval, called the RJ interval, decreased for all subjects following the release of intrathoracic strain compared to the resting value, suggesting that it is inversely correlated to cardiac contractility. The power spectrum magnitude of the BCGs showed that the high frequency content increased after release, also consistent with increased contractility (faster ejection). Additionally, J-wave amplitudes increased following release, suggesting that it is correlated to stroke volume. Since RJ interval computation required the ECG, BCG J-wave rise time was proposed as an alternative for evaluating cardiac contractility. The correlation between this rise time and RJ interval was high (R2=0.78).

Entities:  

Mesh:

Year:  2008        PMID: 19162745     DOI: 10.1109/IEMBS.2008.4649242

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Estimation of central aortic forces in the ballistocardiogram under rest and exercise conditions.

Authors:  Richard M Wiard; Hyun Jin Kim; C Figueroa; Gregory T A Kovacs; Charles A Taylor; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

2.  Quantifying and Reducing Posture-Dependent Distortion in Ballistocardiogram Measurements.

Authors:  Abdul Qadir Javaid; Andrew D Wiens; Nathaniel Forrest Fesmire; Mary Ann Weitnauer; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2015-06-04       Impact factor: 5.772

3.  An ear-worn continuous ballistocardiogram (BCG) sensor for cardiovascular monitoring.

Authors:  David Da He; Eric S Winokur; Charles G Sodini
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

4.  Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability.

Authors:  Gaurav Parchani; Gulshan Kumar; Raghavendra Rao; Kaviraja Udupa; Vibhor Saran
Journal:  Ann Neurosci       Date:  2022-02-02

5.  In-Home Cardiovascular Monitoring System for Heart Failure: Comparative Study.

Authors:  Nicholas J Conn; Karl Q Schwarz; David A Borkholder
Journal:  JMIR Mhealth Uhealth       Date:  2019-01-18       Impact factor: 4.773