Literature DB >> 19161202

Contiguous-slice zonally oblique multislice (CO-ZOOM) diffusion tensor imaging: examples of in vivo spinal cord and optic nerve applications.

Nicholas G Dowell1, Thomas M Jenkins, Olga Ciccarelli, David H Miller, Claudia A M Wheeler-Kingshott.   

Abstract

PURPOSE: To describe and demonstrate a new technique that allows diffusion tensor imaging of small structures such as the spinal cord (SC) and optic nerve (ON) with contiguous slices and reduced image distortions using a narrow field of view (FOV).
MATERIALS AND METHODS: Images were acquired with a modified single-shot echo-planar imaging (EPI) sequence that contains a refocusing radio frequency (RF) pulse in the presence of the phase-encoding (rather than slice-select) gradient. As a result, only a narrow volume may be both excited and refocused, removing the problem of signal aliasing for narrow FOVs. Two variants of this technique were developed: cardiac gating is included in the study of the SC to reduce pulsation artifacts, whereas inversion-recovery (IR) cerebrospinal fluid (CSF) suppression is utilized in the study of the ON to eliminate partial volume effects. The technique was evaluated with phantoms, and mean diffusivity (MD) and fractional anisotropy (FA) measurements were made in the SC and ON of two healthy volunteers.
RESULTS: The technique provides contiguous-slice, reduced-FOV images that do not suffer from aliasing and have reduced magnetic susceptibility artifacts. MD and FA values determined here lie within the ranges quoted in the literature.
CONCLUSION: Contiguous-slice zonally orthogonal multislice (CO-ZOOM-EPI is a new technique for diffusion-weighted imaging of small structures such as the ON and SC with high resolution and reduced distortions due to susceptibility variations. This technique is able to acquire contiguous slices that may allow further nerve-tracking analyses.

Mesh:

Year:  2009        PMID: 19161202     DOI: 10.1002/jmri.21656

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

1.  Development of a high-resolution fat and CSF-suppressed optic nerve DTI protocol at 3T: application in multiple sclerosis.

Authors:  R S Samson; M Kolappan; D L Thomas; M R Symms; P Connick; D H Miller; Claudia A M Wheeler-Kingshott
Journal:  Funct Neurol       Date:  2013 Apr-May

2.  Improved diffusion tensor imaging of the optic nerve using multishot two-dimensional navigated acquisitions.

Authors:  Ha-Kyu Jeong; Blake E Dewey; Jane A T Hirtle; Patrick Lavin; Subramaniam Sriram; Siddharama Pawate; John C Gore; Adam W Anderson; Hakmook Kang; Seth A Smith
Journal:  Magn Reson Med       Date:  2014-09-26       Impact factor: 4.668

Review 3.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

4.  High-resolution human cervical spinal cord imaging at 7 T.

Authors:  E E Sigmund; G A Suero; C Hu; K McGorty; D K Sodickson; G C Wiggins; J A Helpern
Journal:  NMR Biomed       Date:  2011-12-20       Impact factor: 4.044

5.  Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

Authors:  Christopher J Wargo; John C Gore
Journal:  Magn Reson Imaging       Date:  2013-03-29       Impact factor: 2.546

6.  Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T.

Authors:  Samantha By; Alex K Smith; Lindsey M Dethrage; Bailey D Lyttle; Bennett A Landman; Jeffrey L Creasy; Siddharama Pawate; Seth A Smith
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

7.  Recovery after spinal cord relapse in multiple sclerosis is predicted by radial diffusivity.

Authors:  Patrick Freund; Claudia Wheeler-Kingshott; Jonathan Jackson; David Miller; Alan Thompson; Olga Ciccarelli
Journal:  Mult Scler       Date:  2010-08-04       Impact factor: 6.312

8.  Diffusion tensor imaging and T2 relaxometry of bilateral lumbar nerve roots: feasibility of in-plane imaging.

Authors:  Dimitrios C Karampinos; Gerd Melkus; Timothy M Shepherd; Suchandrima Banerjee; Emine U Saritas; Ajit Shankaranarayanan; Christopher P Hess; Thomas M Link; William P Dillon; Sharmila Majumdar
Journal:  NMR Biomed       Date:  2012-12-04       Impact factor: 4.044

9.  Image domain propeller fast spin echo.

Authors:  Stefan Skare; Samantha J Holdsworth; Anders Lilja; Roland Bammer
Journal:  Magn Reson Imaging       Date:  2012-11-30       Impact factor: 2.546

Review 10.  The current state-of-the-art of spinal cord imaging: methods.

Authors:  P W Stroman; C Wheeler-Kingshott; M Bacon; J M Schwab; R Bosma; J Brooks; D Cadotte; T Carlstedt; O Ciccarelli; J Cohen-Adad; A Curt; N Evangelou; M G Fehlings; M Filippi; B J Kelley; S Kollias; A Mackay; C A Porro; S Smith; S M Strittmatter; P Summers; I Tracey
Journal:  Neuroimage       Date:  2013-05-14       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.