Literature DB >> 19158887

Interval type-II fuzzy anisotropic diffusion algorithm for speckle noise reduction in optical coherence tomography images.

Prabakar Puvanathasan1, Kostadinka Bizheva.   

Abstract

A novel speckle noise reduction algorithm based on a combination of Anisotropic Diffusion (AD) filtering and Interval Type-II fuzzy system was developed for reducing speckle noise in Optical Coherence Tomography (OCT) images. Unlike regular AD, the Interval Type-II fuzzy based AD algorithm considers the uncertainty in the calculated diffusion coefficient and appropriate adjustments to the coefficient are made. The new algorithm offers flexibility in optimizing the trade-off between the two image metrics: signal-to-noise (SNR) and Edginess, which are directly related to the structure of the imaged object. Application of the Interval Type-II fuzzy AD algorithm to OCT tomograms acquired in-vivo from a human finger tip and human retina show reduction in the speckle noise with very little edge blurring and about 13 dB and 7 dB image SNR improvement respectively. Comparison with Wiener, Adaptive Lee and regular Anisotropic Diffusion filters, applied to the same images, demonstrates the superior performance of the fuzzy Type-II AD algorithm in terms image SNR and edge preservation metrics improvement.

Entities:  

Year:  2009        PMID: 19158887     DOI: 10.1364/oe.17.000733

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  17 in total

Review 1.  State-of-the-art in retinal optical coherence tomography image analysis.

Authors:  Ahmadreza Baghaie; Zeyun Yu; Roshan M D'Souza
Journal:  Quant Imaging Med Surg       Date:  2015-08

2.  Automated quantification of lung structures from optical coherence tomography images.

Authors:  Alex M Pagnozzi; Rodney W Kirk; Brendan F Kennedy; David D Sampson; Robert A McLaughlin
Journal:  Biomed Opt Express       Date:  2013-10-09       Impact factor: 3.732

3.  Multi-penalty conditional random field approach to super-resolved reconstruction of optical coherence tomography images.

Authors:  Ameneh Boroomand; Alexander Wong; Edward Li; Daniel S Cho; Betty Ni; Kostandinka Bizheva
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

4.  Speckle noise reduction in optical coherence tomography images based on edge-sensitive cGAN.

Authors:  Yuhui Ma; Xinjian Chen; Weifang Zhu; Xuena Cheng; Dehui Xiang; Fei Shi
Journal:  Biomed Opt Express       Date:  2018-10-02       Impact factor: 3.732

5.  Speckle reduction in optical coherence tomography images based on wave atoms.

Authors:  Yongzhao Du; Gangjun Liu; Guoying Feng; Zhongping Chen
Journal:  J Biomed Opt       Date:  2014-05       Impact factor: 3.170

6.  Adaptive anisotropic diffusion for noise reduction of phase images in Fourier domain Doppler optical coherence tomography.

Authors:  Shaoyan Xia; Yong Huang; Shizhao Peng; Yanfeng Wu; Xiaodi Tan
Journal:  Biomed Opt Express       Date:  2016-07-05       Impact factor: 3.732

Review 7.  Involuntary eye motion correction in retinal optical coherence tomography: Hardware or software solution?

Authors:  Ahmadreza Baghaie; Zeyun Yu; Roshan M D'Souza
Journal:  Med Image Anal       Date:  2017-02-04       Impact factor: 8.545

8.  Self-fusion for OCT noise reduction.

Authors:  Ipek Oguz; Joseph D Malone; Yigit Atay; Yuankai K Tao
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-10

9.  Automated detection and cell density assessment of keratocytes in the human corneal stroma from ultrahigh resolution optical coherence tomograms.

Authors:  Amir-Hossein Karimi; Alexander Wong; Kostadinka Bizheva
Journal:  Biomed Opt Express       Date:  2011-09-29       Impact factor: 3.732

10.  Automated segmentation of intraretinal cystoid fluid in optical coherence tomography.

Authors:  Gary R Wilkins; Odette M Houghton; Amy L Oldenburg
Journal:  IEEE Trans Biomed Eng       Date:  2012-01-16       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.