Literature DB >> 19157352

Randomised comparison of the Classic Laryngeal Mask Airway with the Cobra Perilaryngeal Airway during anaesthesia in spontaneously breathing adult patients.

D T Andrews1, D L Williams, K D Alexander, Y Lie.   

Abstract

We tested the hypothesis that the Cobra Perilaryngeal Airway (PLA) with its high volume low-pressure cuff would provide superior airway leakage pressure compared with the Classic Laryngeal Mask Airway (LMA) in spontaneously breathing adult patients. Ninety consecutive adult patients were randomly allocated to receive one of these two supralaryngeal devices. The airway leakage pressure was higher for the PLA compared with the LMA (22 +/- 9 cmH2O vs. 18 +/- 6 cmH2O; P < 0.05). The mean airway device intracuff pressure was lower for the PLA compared to the LMA (36.1 +/- 15.2 mmHg vs. 86.3 +/- 25.3 mmHg P < 0.0001). The time required to achieve successful insertion was greater for the PLA compared with the LMA (39 +/- 21 seconds vs. 27 +/- 10 seconds; P < 0.005). The number of attempts required to achieve successful insertion and the incidence of postoperative complications were similar in both groups. The findings suggest that the PLA provides a superior airway seal at a lower intracuff pressure compared to the LMA. However the time for successful insertion may be increased.

Entities:  

Mesh:

Year:  2009        PMID: 19157352     DOI: 10.1177/0310057X0903700107

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  6 in total

1.  Comparing the Laryngeal Mask Airway, Cobra Perilaryngeal Airway and Face Mask in Children Airway Management.

Authors:  Beyza Tekin; Zehra Hatipoğlu; Mediha Türktan; Dilek Özcengiz
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-04-01

2.  Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery.

Authors:  Gökhan Peker; Suna Akın Takmaz; Bülent Baltacı; Hülya Başar; Mustafa Kotanoğlu
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-08-21

3.  Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Authors:  Yuan Tan; Guangyou Duan; Qin Chen; Feng Chen; Hong Li
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

Review 4.  A Literature Review of Factors Related to Postoperative Sore Throat.

Authors:  Yuta Mitobe; Yuri Yamaguchi; Yasuko Baba; Tomomi Yoshioka; Kenji Nakagawa; Takeshi Itou; Kiyoyasu Kurahashi
Journal:  J Clin Med Res       Date:  2022-02-24

5.  Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery.

Authors:  Rani A Sunder; Renu Sinha; Anil Agarwal; Bala Chandran Sundara Perumal; Sakthi Rajan Paneerselvam
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-07

6.  Extraglottic airway devices: A review.

Authors:  Ramesh Ramaiah; Debasmita Das; Sanjay M Bhananker; Aaron M Joffe
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.