Literature DB >> 1915680

Age-related changes in local water and protein content of human eye lenses measured by Raman microspectroscopy.

I Siebinga1, G F Vrensen, F F De Mul, J Greve.   

Abstract

The Raman microspectroscopic method was used to determine the local water and protein content in human lenses. In 18 lenses of varying age position-defined water/protein content measurements were carried out along the visual and the equatorial axis. A main characteristic of the human lens is its constant and relatively low protein content. In addition this constant nuclear value is reached within a short distance from the capsular surface. For statistical analysis of age-related changes the data points in individual lenses were piecewise linearized. (1) The mean nuclear water content was calculated from the data points in the inner 80% of the visual axis. (2) The steep drop in water content was linearized using a least-squares linear regression approach. The distance between lenticular surface and the intersection of the regression line with the line representing the nuclear mean was denominated as surface layer width. It proved that: (i) the mean nuclear water content significantly increased with age, (ii) the width of the surface layer was age independent in the anterior and posterior poles of the visual axis, and (iii) in the equatorial axis the surface layer width significantly decreased with age. Seven human lenses with small opaque spots were also investigated. The opaque spots proved to have a normal-for-site water content and some of them were flanked at their capsular side by a zone with a high-for-site water content.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1915680     DOI: 10.1016/0014-4835(91)90079-t

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  17 in total

Review 1.  On the growth and internal structure of the human lens.

Authors:  Robert C Augusteyn
Journal:  Exp Eye Res       Date:  2010-02-18       Impact factor: 3.467

2.  Amyloid found in human cataracts with two-dimensional infrared spectroscopy.

Authors:  Ariel M Alperstein; Joshua S Ostrander; Tianqi O Zhang; Martin T Zanni
Journal:  Proc Natl Acad Sci U S A       Date:  2019-03-20       Impact factor: 11.205

Review 3.  The optics of the eye-lens and lenticular senescence. A review.

Authors:  B K Pierscionek; R A Weale
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

4.  Shortwave-infrared Raman spectroscopic classification of water fractions in articular cartilage ex vivo.

Authors:  Mustafa Unal; Ozan Akkus
Journal:  J Biomed Opt       Date:  2018-01       Impact factor: 3.170

Review 5.  The cause and consequence of fiber cell compaction in the vertebrate lens.

Authors:  Steven Bassnett; M Joseph Costello
Journal:  Exp Eye Res       Date:  2016-03-15       Impact factor: 3.467

6.  Aquaporin 5 knockout mouse lens develops hyperglycemic cataract.

Authors:  S Sindhu Kumari; Kulandaiappan Varadaraj
Journal:  Biochem Biophys Res Commun       Date:  2013-10-19       Impact factor: 3.575

7.  Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration.

Authors:  S Sindhu Kumari; Kulandaiappan Varadaraj
Journal:  Biochem Biophys Res Commun       Date:  2014-09-16       Impact factor: 3.575

8.  Ultrahigh field MRI determination of water diffusion rates in ex vivo human lenses of different age.

Authors:  Thomas Stahnke; Tobias Lindner; Rudolf Guthoff; Oliver Stachs; Andreas Wree; Sönke Langner; Thoralf Niendorf; Niels Grabow; Änne Glass; Ebba Beller; Stefan Polei
Journal:  Quant Imaging Med Surg       Date:  2021-07

9.  Growth of the human eye lens.

Authors:  Robert C Augusteyn
Journal:  Mol Vis       Date:  2007-02-23       Impact factor: 2.367

10.  The effect of paraformaldehyde fixation and PBS storage on the water content of the human lens.

Authors:  Robert C Augusteyn; Gijs Vrensen; Ben Willekens
Journal:  Mol Vis       Date:  2008-01-17       Impact factor: 2.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.