Statistical region-based segmentation of ultrasound images.

Greg Slabaugh1, Gozde Unal, Micheal Wels, Tong Fang, Bimba Rao.   

Abstract

Segmentation of ultrasound images is a challenging problem due to speckle, which corrupts the image and can result in weak or missing image boundaries, poor signal to noise ratio and diminished contrast resolution. Speckle is a random interference pattern that is characterized by an asymmetric distribution as well as significant spatial correlation. These attributes of speckle are challenging to model in a segmentation approach, so many previous ultrasound segmentation methods simplify the problem by assuming that the speckle is white and/or Gaussian distributed. Unlike these methods, in this article we present an ultrasound-specific segmentation approach that addresses both the spatial correlation of the data as well as its intensity distribution. We first decorrelate the image and then apply a region-based active contour whose motion is derived from an appropriate parametric distribution for maximum likelihood image segmentation. We consider zero-mean complex Gaussian, Rayleigh, and Fisher-Tippett flows, which are designed to model fully formed speckle in the in-phase/quadrature (IQ), envelope detected, and display (log compressed) images, respectively. We present experimental results demonstrating the effectiveness of our method and compare the results with other parametric and nonparametric active contours.

Mesh:

Year:  2009        PMID: 19152999     DOI: 10.1016/j.ultrasmedbio.2008.10.014

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Modeling the envelope statistics of three-dimensional high-frequency ultrasound echo signals from dissected human lymph nodes.

Authors:  Thanh Minh Bui; Alain Coron; Jonathan Mamou; Emi Saegusa-Beecroft; Tadashi Yamaguchi; Eugene Yanagihara; Junji Machi; S Lori Bridal; Ernest J Feleppa
Journal:  Jpn J Appl Phys (2008)       Date:  2014       Impact factor: 1.480

2.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging.

Authors:  Brooks D Lindsey; Edward D Light; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

3.  Ultrasound histogram assessment of parotid gland injury following head-and-neck radiotherapy: a feasibility study.

Authors:  Xiaofeng Yang; Srini Tridandapani; Jonathan J Beitler; David S Yu; Emi J Yoshida; Walter J Curran; Tian Liu
Journal:  Ultrasound Med Biol       Date:  2012-07-03       Impact factor: 2.998

4.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

5.  A Split-and-Merge-Based Uterine Fibroid Ultrasound Image Segmentation Method in HIFU Therapy.

Authors:  Menglong Xu; Dong Zhang; Yan Yang; Yu Liu; Zhiyong Yuan; Qianqing Qin
Journal:  PLoS One       Date:  2015-05-14       Impact factor: 3.240

6.  Robust myocardial motion tracking for echocardiography: variational framework integrating local-to-global deformation.

Authors:  Chi Young Ahn
Journal:  Comput Math Methods Med       Date:  2013-03-11       Impact factor: 2.238

  6 in total