Using the GRAPPA operator and the generalized sampling theorem to reconstruct undersampled non-Cartesian data.

Nicole Seiberlich1, Felix A Breuer, Philipp Ehses, Hisamoto Moriguchi, Martin Blaimer, Peter M Jakob, Mark A Griswold.   

Abstract

As expected from the generalized sampling theorem of Papoulis, the use of a bunched sampling acquisition scheme in conjunction with a conjugate gradient (CG) reconstruction algorithm can decrease scan time by reducing the number of phase-encoding lines needed to generate an unaliased image at a given resolution. However, the acquisition of such bunched data requires both modified pulse sequences and high gradient performance. A novel method of generating the "bunched" data using self-calibrating GRAPPA operator gridding (GROG), a parallel imaging method that shifts data points by small distances in k-space (with Deltak usually less than 1.0, depending on the receiver coil) using the GRAPPA operator, is presented here. With the CG reconstruction method, these additional "bunched" points can then be used to reconstruct an image with reduced artifacts from undersampled data. This method is referred to as GROG-facilitated bunched phase encoding (BPE), or GROG-BPE. To better understand how the patterns of bunched points, maximal blip size, and number of bunched points affect the reconstruction quality, a number of simulations were performed using the GROG-BPE approach. Finally, to demonstrate that this method can be combined with a variety of trajectories, examples of images with reduced artifacts reconstructed from undersampled in vivo radial, spiral, and rosette data are shown.

Mesh:

Year:  2009        PMID: 19145634     DOI: 10.1002/mrm.21891

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  RT-GROG: parallelized self-calibrating GROG for real-time MRI.

Authors:  Haris Saybasili; J Andrew Derbyshire; Peter Kellman; Mark A Griswold; Cengizhan Ozturk; Robert J Lederman; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

2.  RARE/turbo spin echo imaging with Simultaneous Multislice Wave-CAIPI.

Authors:  Borjan A Gagoski; Berkin Bilgic; Cornelius Eichner; Himanshu Bhat; P Ellen Grant; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2015-02-02       Impact factor: 4.668

3.  Wave-CAIPI for highly accelerated 3D imaging.

Authors:  Berkin Bilgic; Borjan A Gagoski; Stephen F Cauley; Audrey P Fan; Jonathan R Polimeni; P Ellen Grant; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2014-07-01       Impact factor: 4.668

4.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

5.  Self-calibrated interpolation of non-Cartesian data with GRAPPA in parallel imaging.

Authors:  Seng-Wei Chieh; Mostafa Kaveh; Mehmet Akçakaya; Steen Moeller
Journal:  Magn Reson Med       Date:  2019-11-13       Impact factor: 4.668

6.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

7.  Rotated stack-of-spirals partial acquisition for rapid volumetric parallel MRI.

Authors:  Weiran Deng; Benjamin Zahneisen; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.