BACKGROUND: We introduce the first robotic ultrasound-guided prostate intervention device and evaluate its safety, accuracy and repeatability.
METHODS: The robotic positioning system (RPS) determines a target's x, y and z axes. It is situated with a biplane ultrasound probe on a mobile horizontal platform. The integrated software acquires ultrasound images for three-dimensional (3D) modelling, coordinates target planning and directs the RPS.
RESULTS: The egg phantom evaluates the software's safety and workflow protocol. Two random targets are planned in each quadrant and biopsy needles are inserted. All were within three separate eggs. Metal wire tips are targeted and their distances from the biopsy needle tips are measured. With 20 wires, < 1 mm accuracy is obtained. Repeatability is demonstrated when previous positions are returned to with similar accuracy.
CONCLUSION: Our device demonstrates safety in a defined boundary with a repeatable accuracy of < 1 mm. It can be used for accurate prostate biopsy and treatment delivery.

Mesh:

Year:  2009        PMID: 19145573     DOI: 10.1002/rcs.232

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  5 in total

Review 1.  Robotic prostate biopsy and its relevance to focal therapy of prostate cancer.

Authors:  Henry Ho; John S P Yuen; Christopher W S Cheng
Journal:  Nat Rev Urol       Date:  2011-09-20       Impact factor: 14.432

2.  Robotic-assisted thermal ablation of liver tumours.

Authors:  Basri Johan Jeet Abdullah; Chai Hong Yeong; Khean Lee Goh; Boon Koon Yoong; Gwo Fuang Ho; Carolyn Chue Wai Yim; Anjali Kulkarni
Journal:  Eur Radiol       Date:  2014-09-05       Impact factor: 5.315

3.  Endocavity Ultrasound Probe Manipulators.

Authors:  Dan Stoianovici; Chunwoo Kim; Felix Schäfer; Chien-Ming Huang; Yihe Zuo; Doru Petrisor; Misop Han
Journal:  IEEE ASME Trans Mechatron       Date:  2013-06       Impact factor: 5.303

4.  Transperineal prostate biopsy: analysis of a uniform core sampling pattern that yields data on tumor volume limits in negative biopsies.

Authors:  Gordon R Kepner; Jeremy V Kepner
Journal:  Theor Biol Med Model       Date:  2010-06-17       Impact factor: 2.432

5.  Outcomes of combination MRI-targeted and transperineal template biopsy in restaging low-risk prostate cancer for active surveillance.

Authors:  Kenneth Chen; Kae Jack Tay; Yan Mee Law; Hakan Aydin; Henry Ho; Christopher Cheng; John Shyi Peng Yuen
Journal:  Asian J Urol       Date:  2017-07-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.