Literature DB >> 19143740

Automated QT measurement and application to detection of moxifloxacin-induced changes.

David W Mortara1.   

Abstract

BACKGROUND: Concern for drug-induced QT prolongation has caused significant investment in QT measurement to safety-test new compounds. Manual methods are expensive and time-consuming. Reliable automatic methods would be highly desirable.
METHODS: Twelve-lead Holter recordings were annotated beat-to-beat by an automatic algorithm for global QRS onset and T offset. T offset was established from the time of peak T downslope plus a rate-dependent offset, analogous to the "tangent method," wherein T offset is determined by extrapolating the T downslope to an intersection with the baseline. RESULTS AND
CONCLUSIONS: Variances of the beat-to-beat QT measurements were in the range 2.5-3.4 ms over three distinct databases, including a large heart failure database. Application to a moxifloxacin/placebo control database of 29 subjects showed excellent results.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19143740      PMCID: PMC6932022          DOI: 10.1111/j.1542-474X.2008.00262.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  3 in total

1.  Precision of QT interval measurement by advanced electrocardiographic equipment.

Authors:  Katerina Hnatkova; Yi Gang; Velislav N Batchvarov; Marek Malik
Journal:  Pacing Clin Electrophysiol       Date:  2006-11       Impact factor: 1.976

2.  Clinical relevance of assessing QT dynamicity in Holter recordings.

Authors:  P Coumel; J Fayn; P Maison-Blanche; P Rubel
Journal:  J Electrocardiol       Date:  1994       Impact factor: 1.438

3.  Rationale and design of the GISSI heart failure trial: a large trial to assess the effects of n-3 polyunsaturated fatty acids and rosuvastatin in symptomatic congestive heart failure.

Authors:  Luigi Tavazzi; Gianni Tognoni; Maria Grazia Franzosi; Roberto Latini; Aldo Pietro Maggioni; Roberto Marchioli; Gian Luigi Nicolosi; Maurizio Porcu
Journal:  Eur J Heart Fail       Date:  2004-08       Impact factor: 15.534

  3 in total
  3 in total

Review 1.  The year of 2009 in electrocardiology.

Authors:  Shlomo Stern
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

2.  Highly automated QT measurement techniques in 7 thorough QT studies implemented under ICH E14 guidelines.

Authors:  Jean-Philippe Couderc; Christine Garnett; Mike Li; Robert Handzel; Scott McNitt; Xiajuan Xia; Slava Polonsky; Wojciech Zareba
Journal:  Ann Noninvasive Electrocardiol       Date:  2011-01       Impact factor: 1.468

3.  Prevalence and prognostic significance of long QT interval among patients with chest pain: selecting an optimum QT rate correction formula.

Authors:  Amer A Hasanien; Barbara J Drew; Jill Howie-Esquivel; Gordon Fung; Patricia Harris
Journal:  J Electrocardiol       Date:  2013-04-15       Impact factor: 1.438

  3 in total