Bone mineral density assessment using the EOS low-dose X-ray device: a feasibility study.

E Sapin1, K Briot, S Kolta, P Gravel, W Skalli, C Roux, D Mitton.   

Abstract

To predict bone strength in the case of osteoporosis, it could be a real benefit to assess the three-dimensional (3D) geometry and the bone mineral density (BMD) with a single low-dose X-ray device, such as the EOS system (Biospace Med, Paris, France). EOS 3D reconstructions of the spine have already been validated. Thus, this study aims at evaluating the accuracy of this low-dose system as a densitometer first ex vivo. The European Spine Phantom (ESP) (number 129) was scanned ten times using both the EOS and a Hologic device (Hologic, Inc., Massachusetts, USA). Accuracy was given by the sum of the systematic error (difference between BMDs assessed and true values given by the phantom manufacturer) and the random error (coefficient of variation). EOS BMDs and Hologic BMDs of 41 ex-vivo vertebrae were calculated and compared. The reproducibility of the method evaluating the EOS BMD was assessed giving the coefficient of variation of three measurements of the 41 vertebrae. The accuracy of the EOS system is below 5.2 per cent, versus 7.2 per cent for the Hologic system in the same conditions. EOS BMDs are significantly higher than Hologic BMDs, but they are strongly correlated. The reproducibility of the method of assessment is equal to 0.95 per cent. The EOS system is accurate for ex-vivo BMD assessments, which is promising regarding the use of this new system to predict vertebral strength.

Entities:  

Mesh:

Year:  2008        PMID: 19143419     DOI: 10.1243/09544119JEIM450

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  3 in total

Review 1.  Quantitative imaging of the spine in adolescent idiopathic scoliosis: shifting the paradigm from diagnostic to comprehensive prognostic evaluation.

Authors:  Saba Pasha; Chamith R Rajapaske; Ravinder Reddy; Bassel Diebo; Patrick Knott; Brandon C Jones; Dushyant Kumar; Winnie Zhu; Edmond Lou; Nadav Shapira; Peter Noel; Victor Ho-Fung; Diego Jaramillo
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-01-31

2.  CORR Insights®: Poor Bone Quality, Multilevel Surgery, and Narrow and Tall Cages Are Associated with Intraoperative Endplate Injuries and Late-onset Cage Subsidence in Lateral Lumbar Interbody Fusion: A Systematic Review.

Authors:  Sergio A Mendoza-Lattes
Journal:  Clin Orthop Relat Res       Date:  2022-01-01       Impact factor: 4.755

3.  EOS(®) biplanar X-ray imaging: concept, developments, benefits, and limitations.

Authors:  Elias Melhem; Ayman Assi; Rami El Rachkidi; Ismat Ghanem
Journal:  J Child Orthop       Date:  2016-02-16       Impact factor: 1.548

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.