Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair.

Roberto Iezzi1, Raffaella Basilico, Daniela Giancristofaro, Danilo Pascali, Antonio Raffaele Cotroneo, Maria Luigia Storto.   

Abstract

PURPOSE: This study assessed the negative predictive value, sensitivity, specificity, and diagnostic accuracy of real-time contrast-enhanced ultrasound imaging (CEUS) in the detection of endoleaks in patients with abdominal aortic aneurysm (AAA) who underwent endovascular repair (EVAR) compared with unenhanced ultrasound imaging. Computed tomography angiography (CTA) was the gold standard. The secondary objective was to define the optimal dose of the second-generation contrast agent to routinely use in the CEUS examinations for endoleak detection.
METHODS: The study enrolled 84 patients with unruptured AAA who were treated with EVAR and underwent CTA follow-up. In the same day, CTA (4- x 1-mm collimation, 1.25-mm slice width), unenhanced US imaging and CEUS imaging was performed in all patients. The CEUS studies were performed after an intravenous bolus injection of 1.2 mL and 2.4 mL of a second-generation contrast agent with continuous low-mechanical index (range, 0.01-0.04) real-time tissue harmonic imaging. The unenhanced US and CEUS studies were interpreted separately by two independent experienced readers to detect the presence of endoleaks by viewing recorded videotapes according to a five-point confidence scale. The standard of reference was represented by the consensus reading of CTA performed by two experienced radiologists not involved in the image analysis. Qualitative analysis as well as sensitivity, specificity, negative predictive value, and diagnostic accuracy in detecting endoleaks of each reading session were compared.
RESULTS: CEUS imaging significantly improved the diagnostic performance of unenhanced US studies in the detection of endoleaks in terms of sensitivity (97.5% vs 62.5%), negative predictive value (97.3% vs 65.1%), accuracy (89.3% vs 63.1%), and specificity (81.8% vs 63.6%). The optimal dose of contrast agent to detect and characterize endoleaks was 2.4 mL. No adverse events were recorded during the study.
CONCLUSIONS: The results showed CEUS imaging is a fast, noninvasive, reliable, and valid alternative to multislice CTA for endoleak detection in endovascular aortic stent graft patients, and is superior to unenhanced US imaging. Contrast-enhanced ultrasound imaging should be performed using a recommended contrast medium dose of 2.4 mL.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19135839     DOI: 10.1016/j.jvs.2008.10.008

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  22 in total

1.  [Imaging of endoleaks after endovascular aneurysm repair (EVAR) with contrast-enhanced ultrasound (CEUS)].

Authors:  D-A Clevert; A Horng; R Kopp; K Schick; G Meimarakis; W H Sommer; M Reiser
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

2.  Associated gastroduodenal artery aneurysm aortic aneurysm: the diagnostic contribution of contrast-enhanced ultrasound in correlation with computed tomography angiography.

Authors:  Radu Badea; Liliana Chiorean; Olimpia Chira; Cosmin Caraiani
Journal:  J Med Ultrason (2001)       Date:  2013-11-16       Impact factor: 1.314

Review 3.  Contrast-enhanced ultrasound (CEUS) versus computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients. Are delayed type II endoleaks being missed? A systematic review and meta-analysis.

Authors:  J Chung; A Kordzadeh; I Prionidis; Y Panayiotopoulos; T Browne
Journal:  J Ultrasound       Date:  2015-01-17

4.  CEUS versus CT Angiography in the follow-up of abdominal aortic endoprostheses: diagnostic accuracy and activity-based cost analysis.

Authors:  Niccolo' Faccioli; Giovanni Foti; Giulia Casagranda; Elena Santi; Mirko D'Onofrio
Journal:  Radiol Med       Date:  2018-08-06       Impact factor: 3.469

5.  Endovascular repair of abdominal aortic aneurysms in low surgical risk patients: an evidence update.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-01-01

Review 6.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

7.  Role of multidetector CT angiography and contrast-enhanced ultrasound in redefining follow-up protocols after endovascular abdominal aortic aneurysm repair.

Authors:  R Motta; L Rubaltelli; R Vezzaro; V Vida; P Marchesi; R Stramare; A Zanon; M Battistel; M Sommavilla; D Miotto
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

Review 8.  A Narrative Review on Contrast-Enhanced Ultrasound in Aortic Endograft Endoleak Surveillance.

Authors:  Sriharsha Gummadi; John R Eisenbrey; Andrej Lyshchik
Journal:  Ultrasound Q       Date:  2018-09       Impact factor: 1.657

9.  Is contrast-enhanced ultrasound (CEUS) superior to computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients? A systematic review and meta-analysis.

Authors:  Amer Harky; Ewa Zywicka; Giovanni Santoro; Lucas Jullian; Mihika Joshi; Sameh Dimitri
Journal:  J Ultrasound       Date:  2019-02-15

10.  Endoleak detection after endovascular aneurysm repair using unenhanced MRI with flow suppression technique: Feasibility study in comparison with contrast-enhanced CT.

Authors:  Kensaku Mori; Tsukasa Saida; Fujio Sato; Yoko Uchikawa; Takahiro Konishi; Toshitaka Ishiguro; Takashi Hiyama; Sodai Hoshiai; Yoshikazu Okamoto; Katsuhiro Nasu; Manabu Minami
Journal:  Eur Radiol       Date:  2016-03-24       Impact factor: 5.315